Please  Read  This  Before  Installing  Or  Operating  Pump. 
This  information  is  provided  for 

SAFETY  and  to  PREVENT 

EQUIPMENT  PROBLEMS

.  To  help  recognize  this  information, 

observe the following symbols:

IMPORTANT!

  Warns  about  hazards  that  can  result 

in  personal  injury  orIndicates  factors  concerned  with 
assembly,  installation,  operation,  or  maintenance  which 
could  result  in  damage  to  the  machine  or  equipment  if 
ignored.

CAUTION  !

  Warns  about  hazards  that  can  or  will  cause  minor 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING !

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only  qualifi ed  personnel  should  install,  operate  and  repair 
pump. Any  wiring  of  pumps  should  be  performed  by  a  qualifi ed 
electrician.  

WARNING ! -

 To reduce risk of electrical shock, pumps 

and  control  panels  must  be  properly  grounded  in 
accordance with the National Electric Code (NEC) or the 
Canadian Electrical Code (CEC) and all applicable state, 
province, local codes and ordinances. 

WARNING!  -

 To  reduce  risk  of  electrical  shock,  always 

disconnect  the  pump  from  the  power  source  before 
handling or servicing. Lock out power and tag.

Prevent  large  articles  of  clothing,  large  amounts  of  chemicals, 
other materials or substances such as are uncommon in domestic 
sewage from entering the system.

During  power  black-outs,  minimize  water  consumption  at  the 
home(s) to prevent sewage from backing up into the house.

Always  keep  the  shut-off  valve  completely  open  when  system  is 
in operation (unless advised otherwise by the proper authorities). 
Before  removing  the  pump  from  the  basin,  be  sure  to  close  the 
shut-off valve. (This prevents backfl ow from the pressure sewer.)

Keep the control panel locked or confi ned to prevent unauthorized 
access to it.

If the pump is idle for long periods of time, it is advisable to start the 
pump occasionally by adding water to the basin.

CAUTION! 

Pumps  build  up  heat  and  pressure 

during  operation-allow  time  for  pumps  to  cool 
before handling or servicing. 

WARNING!

  - 

DO  NOT

  pump  hazardous  materials 

(fl ammable, caustic, etc.) unless the pump is specifi cally 
designed and designated to handle them.

Do  not  block  or  restrict  discharge  hose,  as  discharge  hose  may 
whip under pressure. 

WARNING!  -  DO  NOT

  wear  loose  clothing  that  may 

become entangled in the impeller or other moving parts. 

WARNING!  - 

Keep  clear  of  suction  and  discharge 

openings.  DO  NOT  insert  fi ngers  in  pump  with  power 
connected.

Make sure lifting handles are securely fastened each time before 
lifting.  Do  not  operate  pump  without  safety  devices  in  place. 
Always  replace  safety  devices  that  have  been  removed  during 
service or repair.

Do  not  exceed  manufacturers  recommendation  for  maximum 
performance, as this could cause the motor to overheat.

Secure  the  pump  in  its  operating  position  so  it  can  not  tip  over, 
fall or slide.

Cable  should  be  protected  at  all  times  to  avoid  punctures,  cut, 
bruises and abrasions - inspect frequently. 

Never handle connected power cords with wet hands.

To reduce risk of electrical shock, all wiring and junction 
connections  should  be  made  per  the  NEC  or  CEC 
and  applicable  state  or  province  and  local  codes. 
Requirements  may  vary  depending  on  usage  and 
location.

Submersible  Pumps  are  not  approved  for  use  in 
swimming  pools,  recreational  water  installations, 
decorative  fountains  or  any  installation  where  human 
contact with the pumped fl uid is common.

Do  not  remove  cord  and  strain  relief.  Do  not  connect  conduit  to 
pump. 

Products  Returned  Must  Be  Cleaned,  Sanitized,  Or 
Decontaminated  As  Necessary  Prior  To  Shipment,  To 
Insure That  Employees  Will  Not  Be  Exposed To  Health 
Hazards  In  Handling  Said  Material. All Applicable  Laws 
And Regulations Shall Apply.
 
Bronze/brass and bronze/brass fi tted pumps may 
contain lead levels higher than considered safe for 
potable water systems. Lead is known to cause cancer 
and birth defects or other reproductive harm. Various 
government agencies have determined that leaded 
copper alloys should not be used in potable water 
applications. For non-leaded copper alloy materials of 
construction, please contact factory. 

IMPORTANT!  -

  Crane  Pumps  &  Systems,  Inc.  is  not 

responsible  for  losses,  injury,  or  death  resulting  from  a 
failure  to  observe  these  safety  precautions,  misuse  or 
abuse of pumps or equipment.

SAFETY FIRST!

Hazardous fl uids can 
cause fi re or explo-
sions, burnes or death 
could result.

Extremely hot - Severe 
burnes can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous fl uids can Hazard-
ous pressure, eruptions or ex-
plosions could cause personal 
injury or property damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Other brand and product names are trademarks or registered trademarks of their respective holders.
® Barnes is a registered trademark of Crane Pumps & Systems, Inc.
 2002, 4/04, 5/06, 9/06, 1/07   

 

 

 

 

 

 

 

Alteration Rights Reserved

Содержание PGPP2022

Страница 1: ...nt program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 112871 Rev K ProGrind Series PGPP 2 HP 3450 RPM 60 Hz DISCONTINUED Parts may NOT be av...

Страница 2: ...ng parts WARNING Keep clear of suction and discharge openings DO NOT insert fingers in pump with power connected Make sure lifting handles are securely fastened each time before lifting Do not operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Do not exceed manufacturers recommendation for maximum performance as this could caus...

Страница 3: ...e Barnes UltraGRIND grinder pump station The basin collects all wastewater from the house The solids in the sewage are then ground to a small size suitable for pumping in the slurry The grinder pump generates sufficient pressure to pump this slurry from your home to the wastewater plant Power Failure Your grinder pump cannot dispose of wastewater or provide an alarm signal without electrical power ...

Страница 4: ...AINT Air dry enamel SEAL Design Single Mechanical Material Rotating Faces Silicon Carbide Stationary Faces Silicon Carbide Elastomer Buna N Hardware 300 series stainless steel CORD ENTRY 20 Ft 6m Cord with Plug Custom Molded Quick Connected for sealing and strain relief CORD CSA UL Approved 14 3 Type SOW SPEED 3450 RPM 60Hz nominal UPPER BEARING Design Single Row Ball Oil Lubricated Load Radial LO...

Страница 5: ...storage and all surfaces that have the paint scratched damaged or worn should be recoated with a air dry enamel paint All surfaces should then be sprayed with a rust inhibiting oil Pump should be stored in its original shipping container On initial start up rotate shaft by hand to assure seal and motor rotate freely If it is required that the pump be installed and tested before the long term stora...

Страница 6: ...ROL CABLES TO LIFT PUMP Overload Protection The type of in winding overload protector used is referred to as an inherent overheating protectorandoperatesonthecombinedeffectoftemperature and current This means that the overload protector will trip out and shut the pump off if the windings become too hot or the load current passing through them becomes too high It will then automatically reset and s...

Страница 7: ...heck cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Remove examine for damage Replace pump stator if required 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits fl...

Страница 8: ...8 FIGURE 5 ...

Страница 9: ...29034 Cooling Oil Mtr Housing 25 1 095368 Square Ring 26 4 1 300 1 Screw 5 16 18 x 1 25 SS 28 1 061143 Retaining Ring 29 1 Q10 36 E4 Ball Bearing 31 1 108368 Motor 2HP 240 Volt 1 Phase w capacitors Ground wire 31A 1 112470 Capacitor Run 31B 1 099198 Capacitor Start 31C 1 105111B Ground wire 31D 1 016660 Screw Self Tap 8 32 x 31 31E 6 039462 Cable tie strap 34 1 103760 Terminal Block Power Manual I...

Страница 10: ...rformance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATIONS ...

Страница 11: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...

Страница 12: ...O___ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating ___________________ Do protection devices comply with pump and motor Amp rating YES___ NO___ Are all electrical and panel entry connections tight YES___ NO___ Is the interior of the panel dry YES___ NO___ Liquid ...

Страница 13: ...stalled away from turbulence YES___ NO___ Is level control operating properly YES___ NO___ Is pump fully submerged during operation YES___ NO___ Follow up Corrective Action Required YES___ NO___ Additional Comments ____________________________________________________________________________ ____________________________________________________________________________ _______________________________...

Страница 14: ...Notes ...