background image

6

SECTION B: GENERAL INFORMATION

B-1) To the Purchaser:

 

Congratulations! You are the owner of one of the fi nest pumps 
on the market today. CP&S pumps are products engineered 
and manufactured of high quality components. Over one 
hundred years of pump building experience along with a 
continuing quality assurance program combine to produce a 
pump which will stand up to the toughest applications. This 
manual will provide helpful information concerning installation, 
maintenance, and proper service guidelines.

B-2) Receiving:

 

Upon receiving the pump, it should be inspected for damage 
or shortages. If damage has occurred, fi le a claim immediately 
with the company that delivered the pump. If the manual 
is removed from the packaging, do not lose or misplace.

B-3) Storage:
Short Term-

 CP&S Pumps are manufactured for effi cient 

performance following short inoperative periods in storage. 
For best results, pumps can be retained in storage, as factory 
assembled, in a dry atmosphere with constant temperatures 
for up to six (6) months. Long Term- Any length of time 
exceeding six (6) months, but not more than twenty-four (24) 
months. The unit should be stored in a temperature controlled 
area, a roofed over walled enclosure that provides protection 
from the elements (rain, snow, wind-blown dust, etc.), and 
whose temperature can be maintained b40 deg. F 
and +120 deg. F. (4.4 - 49°C). Pump should be stored in its 
original shipping container. On initial start up, rotate impeller 
by hand to assure seal and impeller rotate freely. If it is 
required that the pump be installed and tested before the long 
term storage begins, such installation will be allowed provided:

1.)  The pump is not installed under water for more than
 

one (1) month.

2.)  Immediately upon satisfactory completion of the test,
 

the pump is removed, thoroughly dried, repacked in the

 

original shipping container, and placed in a temperature

 

controlled storage area.

B-4) Service Centers:

 

For the location of the nearest Barnes Service Center, check 
your Barnes representative or Crane Pumps & Systems 
Service Department in Piqua, Ohio, telephone (937) 778-8947 
or Crane Pumps & Systems Canada, in Brampton, Ontario, 
(905) 457-6223.

SECTION C: INSTALLATION

C-1) Location:

These pumping units are self-contained and are recommended 
for use in a sump, lift station or basin. This pump is designed 
to pump sewage, effl uent, or other nonexplosive or noncor-
rosive wastewater and shall 

NOT

 be installed in locations 

classifi ed as hazardous in accordance with the National 
Electrical Code (NEC), ANSI/NFPA 70 or Canadian Electrical 
Code. Never install the pump in a trench, ditch or hole with a 
dirt bottom; the legs will sink into the dirt and the suction will 
become plugged.

C-2) Discharge:

Discharge piping should be as short as possible. Both a 
check valve and a shut-off valve are recommended for each 
pump being used. The check valve is used to prevent back-
fl ow into the sump. Excessive backfl ow can cause fl ooding 
and/or damage to the pump. The shut-off valve is used to 
stop system fl ow during pump or check valve servicing.

C-3) Liquid Level Controls:

The level controls are to be supported by a mounting bracket 
that is attached to the sump wall, cover or junction box. Cord 
grips are used to hold the cords in place on the mounting 
bracket. The control level can be changed by loosening the 
grip and adjusting the cord length as per the plans and speci-
fi cations. Be certain that the level controls cannot hang up or 
foul in it’s swing and that the pump is completely submerged 
when the level control is in the “Off” mode.

C-4) Electrical Connections:
C-4.1) Power & Control Cords:

The cord assembly mounted to the pump must not be modi-
fi ed in any way except for shortening to a specifi c application. 
Any splice between the pump and the control panel must be 
made in accordance with all applicable electric codes. It is 
recommended that a junction box, if used, be mounted out-
side the sump or be of at least Nema 4 (EEMAC-4) construc-
tion if located within the wet well. 

DO NOT USE THE POWER 

OR CONTROL CORDS TO LIFT PUMP.

 

NOTE: The White Wire Is Not A Neutral Or Ground Lead. 
The Black, White And Red Leads Are Power Carrying
Conductors. The Green Lead Is For Connection To 
Ground.

 

C-4.2) Overload Protection :
C-4.2-1) Three Phase - 

The normally closed (N/C) thermal 

sensor is embedded in the motor windings and will detect 
excessive heat in the event an overload condition occurs. The 
thermal sensor will trip when the windings become too hot 
and will automatically reset itself when the pump motor cools 
to a safe temperature. It is recommended that the thermal 
sensor be connected in series to an alarm device to alert the 
operator of an overload condition, and/or the motor starter 
coil to stop the pump. In the event of an overload, the source 
of this condition should be determined and rectifi ed imme-
diately. 

DO NOT LET THE PUMP CYCLE OR RUN IF AN 

OVERLOAD CONDITION OCCURS !

C-4.2-2) Single Phase -

 The type of in-winding overload pro-

tector used is referred to as an inherent overheating protec-
tor and operates on the combined effect of temperature and 
current. This means that the overload protector will trip out 
and shut the pump off if the windings become too hot, or the 
load current passing through them becomes too high. It will 
then automatically reset and start the pump up after the motor 
cools to a safe temperature. In the event of an overload, the 
source of this condition should be determined and rectifi ed 
immediately. 

DO NOT LET THE PUMP CYCLE OR RUN IF 

AN OVERLOAD CONDITION OCCURS !

NOTE:

 Single phase pumps can be orederd with an optional 

Thermal Sensor as well as the standard in winding overload 
protection.

Содержание BARNES 4DSE-L Series

Страница 1: ...he right to change product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 9...

Страница 2: ...8 20 CROSS SECTION Fig 13 21 EXPLODED VIEW Fig 114 15 22 23 PARTS LIST 24 25 RETURNED GOODS POLICY 26 WARRANT START UP REPORT WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TESTER MEGGER...

Страница 3: ...insert ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety d...

Страница 4: ...Hardware 300 series stainless steel CORD ENTRY 40 Ft 12 1m Cord Epoxy sealed housing with secondary pressure grommet for sealing and strain relief SPEED 1150 1750 RPM 60Hz nominal UPPER BEARING Desig...

Страница 5: ...300 series stainless steel CORD ENTRY 40 Ft 12 1m Cord Epoxy sealed housing with secondary pressure grommet for sealing and strain relief SPEED 1150 1750RPM 60Hz nominal UPPER BEARING Design Single Ro...

Страница 6: ...g should be as short as possible Both a check valve and a shut off valve are recommended for each pump being used The check valve is used to prevent back ow into the sump Excessive back ow can cause o...

Страница 7: ...575 3 1150 E 5 4 34 4 10 4 SOW 0 75 4DSE7596L 7 5 200 230 3 1150 B D 24 4 21 3 107 8 124 10 4 SOW 0 75 0 75 4DSE7546L 7 5 460 3 1150 D 10 6 62 0 10 4 SOW 0 75 2 99 4DSE7556L 7 5 575 3 1150 D 8 48 49 6...

Страница 8: ...t a preventive mainte nance program is recommended and suggested to include the following checks 1 Inspect motor and seal chambers for oil level and contamination and repair as required per section F...

Страница 9: ...ler 48 or replace wear ring 60 on High Ef ciency pumps disconnect power remove hex nuts 7 and vertically lift motor and seal assembly from body 43 Clean out body if necessary Clean and ex amine impell...

Страница 10: ...ille washers and shims 10 and 11 in upper end bell Position upper motor end bell aligning holes and thread cap screws into bearing bracket 4 Torque to 16 ft lb Place all motor leads above the motor Po...

Страница 11: ...ce facing bearing bracket 4 slide rotating member 12D onto shaft using seal pusher until lapped faces of 12D and 12E are together See Figure 6 It is extremely important to keep seal faces clean during...

Страница 12: ...s outlined in paragraph F 2 1 Then remove screws 52 and adapter 53 Reassemble by placing gasket 54 and adapter 53 on volute 43 with screws 52 Reassemble volute onto pump assembly as outlined in paragr...

Страница 13: ...uired 7 Shipping instructions 8 Billing Instructions G 2 PART NUMBER The part number consists of a six 6 digit number which ap pears in the catalog A one or two letter suf x may follow this number to...

Страница 14: ...impeller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set...

Страница 15: ...15 FIGURE 10 4DSE L Pump Series...

Страница 16: ...16 FIGURE 11 4DSE L Pump Series...

Страница 17: ...17 4DSE L Pump Series FIGURE 12...

Страница 18: ...1 036852 Gasket Rubber 20 6 033824 Stud 3 8 16 x 2 00 21 1 051937 Square Ring Buna N 22 5 016405 Splice Cap All Except 5Hp 1Ph 7 5Hp 200V 3Ph 030148 Splice Cap For 5Hp 1Ph 7 5Hp 200V 3Ph 23 4 1 529 1...

Страница 19: ...9 00 Dia 084894TQ 8 88 Dia 084894TR 8 75 Dia 5HP STD 084894TS 8 62 Dia 084894TT 8 50 Dia 084894TU 8 38 Dia 084894TV 8 25 Dia 084894TW 8 12 Dia 084894TX 8 00 Dia 084894TY 7 88 Dia 084894TZ 7 75 Dia 08...

Страница 20: ...met For 4DSE5024L ONLY 49E 1 Control Cable Not Sold Separately 49F 1 051448 Gland Nut 49G 1 021531 Friction Ring 49H 1 066871 Grommet 49J 1 030169 Ground Screw 10 32 x 625 Lg Stainless 52 8 24 113 1 F...

Страница 21: ...21 4DSE HL High Ef ciency Pump Series FIGURE 13...

Страница 22: ...22 4DSE HL High Ef ciency Pump Series FIGURE 14...

Страница 23: ...23 4DSE HL High Ef ciency Pump Series FIGURE 15...

Страница 24: ...ainless 19 1 036852 Gasket Rubber 20 6 033824 Stud 3 8 16 x 2 00 21 1 051937 Square Ring Buna N 22 5 016405 Splice Cap All Except 5Hp 1Ph 10Hp 030148 Splice Cap For 5Hp 1Ph 10Hp 23 4 1 529 1 Hex Hd Sc...

Страница 25: ...5Ft 072700XL 100Ft 072700XP 125Ft 072700XS 150Ft 072700XV 175Ft 072700XY 200Ft 49A 1 Power Cable Not Sold Separately 49B 1 051447 Gland Nut 1 072559 Gland Nut For 4DSE5024HL 10HP 49C 2 051450 Friction...

Страница 26: ...o Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the e...

Страница 27: ...27 NOTE...

Страница 28: ...guarantees in the nature of performance speci cations furnished in addition to the foregoing material and workmanship warranties on a product manufactured by us if any are subject to laboratory tests...

Страница 29: ...m Does impeller turn freely by hand Yes No Condition of equipment Good Fair Poor Condition of cable jacket Good Fair Poor Resistance of cable jacket Good Fair Poor Resistance of cable and pump motor m...

Страница 30: ...ction Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for...

Страница 31: ...CITY STATE ZIP MODEL NO SERIAL NO PART NO BRAND IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and return to Crane Pumps Syst...

Страница 32: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA OHIO 45356 U S A FOLD HERE AND TAPE DO NOT STAPLE PLACE STAMP HERE...

Отзывы: