Barnes 4SHV Скачать руководство пользователя страница 1

A Crane Co. Company

BARNES

BARNES

®

INSTALLATION and OPERATION MANUAL

Solids Handling Submersible Pump

IMPORTANT! 

Read all instructions in this manual before operating pump.

 

As a result of Crane Pumps & Systems, Inc., constant product improvement program,

 

product changes may occur. As such Crane Pumps & Systems reserves the right to 

 

change product without prior written notification.

420 Third Street   

83 West Drive, Bramton

Piqua, Ohio 45356 

Ontario, Canada L6T 2J6

Phone: (937) 778-8947 

Phone: (905) 457-6223

Fax: (937) 773-7157 

Fax: (905) 457-2650

www.cranepumps.com

Form No. 125508-50-Rev. P

4SHV

Vortex Pumps

5.5 - 22kW, 2850RPM

4SHM

Monovane Pumps

5.5 - 22kW, 1450RPM

4SHD

Dual Vane Pumps

5.5 - 22kW, 1450RPM

6SHV

Vortex Pumps

11 - 22kW, 1450RPM

5.5 - 11kW, 950RPM

6SHM

Monovane Pumps

11 - 22kW, 1450RPM

5.5 - 11kW, 950RPM

6SHD

Dual Vane Pumps

18 - 22kW, 1450RPM

5.5 - 11kW, 950RPM

This product may be covered by one or more of the following 

patents and other patent(s) pending: US Patent 7,931,473

Содержание 4SHV

Страница 1: ...20 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 125508 50 Rev P 4SHV Vo...

Страница 2: ...BLE SHOOTING 16 SH CROSS SECTIONS Fig 9 10 EXPLODED VIEWS Fig 11 17 18 PARTS LISTS 19 22 WARRANTY 25 WARRANTY REGISTRATION 26 RETURNED GOODS POLICY 26 START UP REPORT 27 28 Other brand and product nam...

Страница 3: ...sert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety d...

Страница 4: ...h a dirt bottom the legs will sink into the dirt and the suction will become plugged B 1 1 Submergence It is recommended that the pump be operated in the Continuous Duty Submergence condition and the...

Страница 5: ...ews into the clamping plate Slowly tighten the two screws alternating back and forth until the clamping plate is drawn down flush to the top of the cord boss on the pump The two screws should be torqu...

Страница 6: ...Pump rated for operation at 10 voltage at motor Cord Suffix XF 50 Feet XJ 75 Feet or XL 100 Feet MODEL NO PART NO KW VOLT PH Hz RPM Nom NEMA START CODE FULL LOAD AMPS 1 2 SERVICE FACTOR AMPS LOCKED RO...

Страница 7: ...D 28 5 33 5 91 7 21 125499 8 4 18 4 SOLD SEPARATELY 4SHDI150Z4 130982 50 15 0 400 3 50 1450 G 33 5 38 9 170 4 21 125499 8 4 18 4 SOLD SEPARATELY 4SHDI185Z4 130597 50 18 5 400 3 50 1450 E 40 4 48 5 170...

Страница 8: ...om NEMA START CODE FULL LOAD AMPS 1 2 SERVICE FACTOR AMPS LOCKED ROTOR AMPS DRIVER FRAME CORD P N CORD SIZE CORD NOTES SHMN Pump 6SHMN55Z4 133128 50 5 5 400 3 50 1450 K 20 0 21 0 91 7 21 125497 12 4 1...

Страница 9: ...RATELY 6SHDK300Z4 132231 50 30 0 400 3 50 1450 D 58 0 72 0 233 9 28 130907 6 4 18 4 INCLUDED WITH PUMP 6SHDK370Z4 132233 50 37 0 400 3 50 1450 E 77 1 92 1 338 0 28 130908 2 4 18 4 INCLUDED WITH PUMP 6...

Страница 10: ...ether T6 T9 Together MOISTURE AND TEMPERATURE SENSORS MOISTURE AND TEMPERATURE SENSORS Control Cable Control Cable Lead ID Lead ID Green Ground Green Brown P1 Temperature Sensor Yellow P2 Temperature...

Страница 11: ...peres 110 120 3 00 30 0 220 240 1 50 15 0 440 480 0 75 7 5 B 4 4 Moisture Sensors A normally open N O detector is installed in the pump seal chamber which will detect any moisture present and a contin...

Страница 12: ...e Sensor Control With a moisture detection control a normally closed push button and neon indicating lamp is typically provided as a means of checking the moisture sensing components When the push but...

Страница 13: ...eakdown refill the seal chamber as per section F 1 2 4 If oil is found to be dirty or contaminated or measures below 15 KV breakdown the pump must be carefully inspected for leaks at the shaft seal 4...

Страница 14: ...cing seal remove stationary 4A from mounting plate by prying out with flat screw driver E 3 2 Reassembly Lightly oil DO NOT use grease outer surface of stationary member 4A Press stationary member 4A...

Страница 15: ...3 MODEL NUMBER This designation consists of numbers and letters which represent the discharge size series horsepower motor phase and voltage speed and pump design This number is used for ordering and...

Страница 16: ...ller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so t...

Страница 17: ...17 FIGURE 9 SH Pump Series Cross Sections FIGURE 10 SH Vortex SH Enclosed...

Страница 18: ...18 FIGURE 11 SH Pump Series Exploded Views APPLY GREEN LOCTITE RC603 TORQUE TO 45 1 4FT LBS APPLY GREEN LOCTITE RC603 TORQUE TO 45 1 4FT LBS...

Страница 19: ...ze 11 125453 Volute Vortex Cast Iron 129994 Volute Enclosed Cast Iron 129995 Volute Enclosed Cast Iron 127254 Volute Enclosed Cast Iron 130830 Volute Enclosed Cast Iron 130831 Volute Enclosed Cast Iro...

Страница 20: ...29863 Ring Snap Tru Arc 5100 175 PH 15 7 Mo Stainless Steel 41 1 127270 Plug Cap 3 37 Tapered PE 42 2 125856 Sensor Moisture 18NPT AMP PP SS 43 1 125450A Bracket Bearing 21 Frame Class 30 CI 44 1 1306...

Страница 21: ...n 127262TM 235mm 9 25in 127262TN 230mm 9 06in 127262TP 225mm 8 86in A Hydraulics Impeller Part No Trim Dia mm in 125454B 205mm 8 07in 125454BTA 200mm 7 87in 125454 205mm 8 07in 125454TA 200mm 7 87in 1...

Страница 22: ...A 365mm 14 37in 130827TB 360mm 14 17in 130827TC 355mm 13 98in 130827TD 350mm 13 78in 130827TE 345mm 13 58in 130827TF 340mm 13 45in 130827TH 330mm 12 99in 130827TJ 325mm 12 80in 130827TK 320mm 12 60in...

Страница 23: ...Notes...

Страница 24: ...Notes...

Страница 25: ...RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products Returned Must Be Cleaned Sanitized Or Decontaminated As Necessary Prior To Shipment To Insure That Employe...