Please Read This Before Installing Or Operating Pump. This 

information is provided for 

SAFETY and to PREVENT 

EQUIPMENT PROBLEMS

. To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result in 

personal injury or Indicates factors concerned with assembly, 

installation, operation, or maintenance which could result in 

damage to the machine or equipment if ignored.

CAUTION !

 Warns about hazards that can or will cause minor personal 

injury or property damage if ignored. Used with symbols below.

WARNING !

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used with 

symbols below.

Only qualified personnel should install, operate and repair pump. Any 

wiring of pumps should be performed by a qualified electrician.  

WARNING ! -

 To reduce risk of electrical shock, pumps and 

control panels must be properly grounded in accordance with 

the National Electric Code (NEC) or the Canadian Electrical 

Code (CEC) and all applicable state, province, local codes and 

ordinances. 

WARNING! -

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before handling 

or servicing. Lock out power and tag.

WARNING!

 Operation against a closed discharge 

valve will cause premature bearing and seal failure 

on any pump, and on end suction and self priming 

pump the heat build may cause the generation of 

steam with resulting dangerous pressures. It is 

recommended that a high case temperature switch 

or pressure relief valve be installed on the pump 

body.

CAUTION !

 Never operate a pump with a plug-in  type 

power cord without a ground fault  circuit interrupter.

CAUTION! 

Pumps build up heat and pressure 

during operation-allow time for pumps to cool 

before handling or servicing. 

WARNING!

 - 

DO NOT

 pump hazardous materials 

(flammable, caustic, etc.) unless the pump is specifically 

designed and designated to handle them.

Do not block or restrict discharge hose, as discharge hose 

may whip under pressure. 

WARNING! - DO NOT

 wear loose clothing that may 

become entangled in the impeller or other moving parts. 

WARNING! - 

Keep clear of suction and discharge openings. 

DO NOT

 insert fingers in pump with power connected.

Always wear eye protection when working on pumps.

Make sure lifting handles are securely fastened each time 

before lifting. 

DO NOT

 operate pump without safety devices 

in place. Always replace safety devices that have been 

removed during service or repair. Secure the pump in its 

operating position so it can not tip over, fall or slide.

DO NOT

 exceed manufacturers recommendation for 

maximum performance, as this could cause the motor to 

overheat.

DO NOT

 remove cord and strain relief. Do not connect 

conduit to pump.

WARNING!

 Cable should be protected at all times to avoid 

punctures, cut, bruises and abrasions - inspect frequently. 

Never handle connected power cords with wet hands.

WARNING!

 To reduce risk of electrical shock, all wiring 

and junction connections should be made per the NEC 

or CEC and applicable state or province and local codes. 

Requirements may vary depending on usage and location.

WARNING!

 Submersible Pumps are not approved for use in 

swimming pools, recreational water installations, decorative 

fountains or any installation where human contact with the 

pumped fluid is common.

WARNING! 

Products Returned Must Be Cleaned, Sanitized, 

Or Decontaminated As Necessary Prior To Shipment, To 

Insure That Employees Will Not Be Exposed To Health 

Hazards In Handling Said Material. All Applicable Laws And 

Regulations Shall Apply.

 

Bronze/brass and bronze/brass fitted pumps may contain 

lead levels higher than considered safe for potable water 

systems. Lead is known to cause cancer and birth defects or 

other reproductive harm. Various government agencies have 

determined that leaded copper alloys should not be used 

in potable water applications. For non-leaded copper alloy 

materials of construction, please contact factory. 

IMPORTANT! -

 Crane Pumps & Systems, Inc. is not 

responsible for losses, injury, or death resulting from a failure 

to observe these safety precautions, misuse or abuse of pumps 

or equipment.

SAFETY FIRST!

Hazardous fluids can 

cause fire or explo

-

sions, burnes or death 

could result.

Extremely hot - Severe 

burnes can occur on contact.

Biohazard can cause 

serious personal injury.

Hazardous fluids can Hazard

-

ous pressure, eruptions or ex

-

plosions could cause personal 

injury or property damage.

Rotating machinery

Amputation or severe 

laceration can result.

Hazardous voltage can 

shock, burn or cause death.

Содержание 3SEH-L

Страница 1: ...ram product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Brampton Piqua Ohio 45356 Ontario Canad...

Страница 2: ...re 11a 11b 15 16 EXPLODED VIEW Figure 12 17 PARTS LIST 18 19 WARRANTY 21 WARRANTY REGISTRATION 22 RETURNED GOODS POLICY 22 SPECIAL TOOLS AND EQUIPMENT INSULATION TESTER MEGGER DIELECTRIC TESTER SEAL T...

Страница 3: ...rt fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety dev...

Страница 4: ...200 230 460 60Hz is Tri voltage motor 575V Requires overload protection to be included in control panel OPTIONAL EQUIPMENT Seal Material Impeller Trims Additional Cord Normally Closed Temperature Sen...

Страница 5: ...t station or basin shall be vented in accordance with local plumbing codes This pump is designed to pump sewage effluent or other nonexplosive or noncorrosive wastewater and shall NOT be installed in...

Страница 6: ...If current through the temperature sensor exceeds the values listed an intermediate control circuit relay must be used to reduce the current or the sensor will not work properly TEMPERATURE SENSOR EL...

Страница 7: ...10 08 12 36 3SE2052L 2 0 575 3 60 3450 C B 4 0 14 4 14 4 SOOW SOW 57 14 5 15 75 14 95 HORIZONTAL Series 3SEH1522L 1 5 230 1 60 3450 A F 12 0 31 0 12 3 SOOW SOW 61 15 5 1 14 4 53 3SEH1592L 1 5 200 230...

Страница 8: ...essure is still holding constant and no bubbles are observed slowly bleed the pressure and remove the gauge assembly Replace oil as described in section F 1 4 If the pressure does not hold then the le...

Страница 9: ...ny control cables 32 if equipped Remove socket head cap screws 9 Vertically lift the motor housing 5 from seal plate 1 by lifting handle 17 Inspect square ring 8 for damage or cuts Remove the motor bo...

Страница 10: ...aragraph F 3 3 Insert female end of cable plug into housing bore aligning timing mark with hole in terminal block 23 38 optional see Figure 6 Compress cable plug with compression flange 30a 32a by tig...

Страница 11: ...e 9 It is extremely important to keep seal faces clean during assembly Dirt particles lodged between these faces will cause the seal to leak Place spring 31c over shaft and in place on rotating member...

Страница 12: ...esign configuration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which represent the discharge size series horsepower mo...

Страница 13: ...13 FIGURE 10...

Страница 14: ...eller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so...

Страница 15: ...15 34 30 5 22 1 6 3 8 24A 10 2 7 32 21 20 OPTIONAL TEMPERATURE SENSOR CABLE ASSEMBLY 29 FIGURE 11a CROSS SECTION VERTICAL DISCHARGE...

Страница 16: ...16 34 30 5 22 1 6 3 8 24B 10 2 7 32 21 20 OPTIONAL TEMPERATURE SENSOR CABLE ASSEMBLY 29 FIGURE 11b CROSS SECTION HORIZONTAL DISCHARGE...

Страница 17: ...17 2 6 8 1 9 9 31 29 10 3 24A 20 25 34 22 21 7 5 11 12 19 41 23 40 30 11 16 38 40 41 32 11 16 a b c d 7 35 WITH OPTIONAL TEMP SENSOR CABLE ASSY 24B FIGURE 12 EXPLODED VIEW...

Страница 18: ...es 230V 3 Phase 19 1 014270 Pipe Plug 375 NPT 20 1 084386MA 3SE1522L 2022L 067572MB 3SE1592L 1542L 092858 3SE1552L 2052L 067572MB 3SE2092L 2042L 21 1 036391 Capacitor 1 phase 370V 45MFD 22 1 039858 Ca...

Страница 19: ...TEMP SENSOR 100 FT TEMP SENSOR TERMINAL BLOCK TEMP SENSOR 3SE1522L None None None None 3SE1592L 103741XC 103741XF 103741XL 103584 3SE1542L 113288XC 113288XF 113288XL 113272 3SE1552L 113288XC 113288XF...

Страница 20: ...20 Notes...

Страница 21: ...ION Your product is covered by a warranty www cranepumps com downloadables CATALOGS_OIPMs Warranty 24MonthWarranty pdf If you have a claim under the provisions of the warranty contact your local Crane...

Отзывы: