B-3) Liquid Level Controls: 

It is recommended to use a liquid level control system 

that allows the on and off point to be separated by at least 

twelve inches. An additional set point (lag point) should 

be incorporated with an alternator switching system for 

a duplex (two pump) station. A high level alarm may be 

required to alert maintenance personnel that there is a 

high water situation in the wet well should the output of the 

pump station drop below the inflow rate. A low level cut off 

may be installed to provide system shutdown if the main 

level control system malfunctions. The off point should be 

positioned so that the liquid level never drops below the 

minimum continuous duty point for the pump shown in 

figure 1.

B-4.1) Electrical Connections:

WARNING! - All model pumps and 

control panels must be properly 

grounded per the NATIONAL 

ELECTRIC CODE or CANADIAN 

ELECTRIC CODE, State, Province 

and local codes. Improper 

grounding voids warranty.

B-4) Power/Control Cord:

 

The power/control cord used with pump has a patented 

“quick disconnect” feature that allows the cord to be easily 

attached and disconnected at the pump. The maximum 

amperage rating for the cord is cast in the top of the cast 

stainless mounting plate. The voltage connection for the 

motor is determined by the cord assembly used. Low 

voltage cords (208 & 230 Volt) utilize a molded quick 

connect plug that is colored black. High voltage cords 

(460 & 575 Volt) utilize a molded quick connect cord 

that is colored orange. 

It is important to verify that the 

cord being used is rated for the nameplate voltage 

and amperage rating shown on the pump nameplate.

 

Refer to Chart on page 7.

 No internal wiring adjustments 

are necessary for dual and tri-voltage pumps. All jumper 

connections to set the proper voltage are made by the cord 

plug itself.

A flat alignment mark is molded into the plug and mating 

socket on the pump. These should be used as a visual 

indication as to the correct orientation of the plug. Insert the 

plug into the pump and install the two 12 mm socket head 

cap screws into the clamping plate. Slowly tighten the two 

screws alternating back and forth until the clamping plate is 

drawn down flush to the top of the cord boss on the pump. 

The two screws should be torqued until the plate is down to 

a point where 

metal to metal

 contact is made between the 

stainless steel plate and pump housing. (See Fig. 2)

The cord assembly mounted to the pump must not be 

modified in any way except for shortening to a specific 

application. Any splice between the pump and the control 

panel must be made in accordance with all applicable 

electric codes. It is recommended that a junction box (if 

used) be mounted outside the sump or be of at least Nema 

6 or 6P construction with NEMA 6 or 6P watertight cord 

grips if located within the wet well. A water and vapor tight 

seal fitting 

MUST

 be used in conduit leaving the wet well 

to prevent moisture and gases from reaching the control 

panel. Prior to installation, the pump power cable should be 

inspected for nicks or damage. If damaged, the cord should 

be replaced before installation. 

CORD CLAMPING PLATE SHOULD BE DRAWN METAL 

TO METAL (50 FT/LBS BOLT TORQUE). IF A GAP 

EXISTS CONTINUE TO TIGHTEN BOLTS. DO NOT USE 

ANY TYPE OF SEALANT OR GREASE ON THE CORD 

ENTRY.

 

DO NOT USE THE POWER CORD TO LIFT PUMP.

B-4.1) Electrical Connections:

When the electrical connections are made, the lead wires 

from the power cable should be stripped so that the ground 

wire is at least two inches longer than the power leads. 

This will ensure that if the cable is inadvertently pulled out 

of the connection point, the ground wire will be the last lead 

to break the circuit.

B-4.2) Wire Size:

 

If additional cable is required consult a qualified electrician 

for proper wire size. Voltage drop due to wire resistance 

between the pump and power connection point should be 

limited to 3% when additional cable is added.

WARRANTY NOTE: 

Both the temperature sensor and moisture 

detection system must be connected to the 

motor circuitry such that the motor will be de-

energized or sound alarm if excessive motor 

temperatures are reached and/or if water is 

detected in the seal chamber and/or motor 

chamber. Failure to have the above mentioned 

systems installed and operative, nullifies 

warranty.

FIGURE 2b

FIGURE 2a

Содержание 3SCM

Страница 1: ...56 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 133030S Rev H 3SCM Monovane Pumps 3 7 5HP 1750RPM 4SCM Monovane Pumps 3 10H...

Страница 2: ...SHOOTING 16 SC CROSS SECTIONS Fig 9 EXPLODED VIEWS Fig 10 17 18 PARTS LISTS AND KITS 19 31 WARRANTY 33 RETURNED GOODS POLICY 34 WARRANTY REGISTRATION 34 START UP REPORT 35 36 Other brand and product...

Страница 3: ...sert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety d...

Страница 4: ...r Crane Pumps Systems Canada in Brampton Ontario 905 457 6223 SECTION B INSTALLATION B 1 Location These self contained pumping units are recommended for use in a sump lift station or basin This pump i...

Страница 5: ...s into the clamping plate Slowly tighten the two screws alternating back and forth until the clamping plate is drawn down flush to the top of the cord boss on the pump The two screws should be torqued...

Страница 6: ...8 6 46 2 125497 2 88 3SCMPA5054 5 0 575 3 60 1750 J 6 0 6 9 37 0 125497 12 4 18 4 86 02 4 32 3SCMPA75N4 7 5 208 3 60 1750 H 23 8 28 5 105 9 123 6 125496 12 4 18 4 86 02 0 43 230 23 7 27 2 0 43 460 11...

Страница 7: ...MC Pump 4SCMC50N4 5 0 208 3 60 1750 J 15 8 18 7 82 4 92 4 125496 12 4 18 4 86 02 0 72 230 15 0 17 2 125496 12 4 18 4 86 02 0 72 460 7 5 8 6 46 2 125497 12 4 18 4 86 02 2 88 4SCMC5054 5 0 575 3 60 1750...

Страница 8: ...4SCDG50N4 5 0 208 3 60 1750 J 15 8 18 7 82 4 92 4 125496 12 4 18 4 86 02 0 72 230 15 0 17 2 125496 12 4 18 4 86 02 0 72 460 7 5 8 6 46 2 125497 12 4 18 4 86 02 2 88 4SCDG5054 5 0 575 3 60 1750 J 6 0 6...

Страница 9: ...r MOISTURE AND TEMPERATURE SENSORS MOISTURE AND TEMPERATURE SENSORS Power Cable Power Cable Lead ID Lead ID Brown P1 Temperature Sensor Yellow P2 Temperature Sensor Orange W1 Moisture Sensor Blue W2 M...

Страница 10: ...IRCUIT Single Phase Cap Chart HP RPM Cap Kit Start Relay Start Cap Run Cap 5 1750 133042 Mars 64 440MFD 330V 50MFD 370V 5 3450 141361 Mars 64 297MFD 330V 40MFD 440V 3 1750 2 1750 Single Phase Start Co...

Страница 11: ...0 220 240 2 00 18 0 B 4 4 Moisture Sensors A normally open N O detector is installed in the pump seal chamber which will detect any moisture present and a continuity test resistor built into the motor...

Страница 12: ...for a three phase installation interchange any two power cable leads at the control box Recheck the kickback rotation again by momentarily applying power C 2 2 Test Procedure For Moisture Sensor Cont...

Страница 13: ...k is done to the pump CAUTION Operating pump builds up heat and pressure allow time for pump to cool to room temperature before handling or servicing E 1 Lubrication E 1 1 Checking Oil 1 Place pump on...

Страница 14: ...or shaft then retaining ring 5 spring 4C and rotating member 4B from shaft See Figure 6 Examine all seal parts and especially contact faces Inspect seal for signs of wear such as uneven wear pattern o...

Страница 15: ...3 MODEL NUMBER This designation consists of numbers and letters which represent the discharge size series horsepower motor phase and voltage speed and pump design This number is used for ordering and...

Страница 16: ...ller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so t...

Страница 17: ...17 SC Pump Series Cross Section 4 5 9 3 2 7 11 8 6 10 8A OIL FILL FIGURE 9...

Страница 18: ...18 FIGURE 10 SC Pump Series Exploded View 35 ITEMS NOT SHOWN 12 31 32...

Страница 19: ...al Mechanical Type 21 1 5 C CE B 4B 1 133029SD Seal Mechanical Type 21 1 5 SC SC B 5 2 133048 Ring Retaining EXT 5100 420 SS 6 1 See Table Impeller Ductile Iron 6A 1 See Table Slicer Blade Stainless 4...

Страница 20: ...en 6 Bar O Ring 8G 38 1 039462 Tie Cable 39 2 125855 Screw SHCS M5 x 0 8 x 8 Stainless Steel 40 2 134013 Connector Wire Clip 49 1 See Table Striker Plate 50 See Table Shims 51 8 143110 Screw SHCS M10...

Страница 21: ...5499XC 30 400 600 59 0 8 4 18 4 1 12in 28 4mm 125499XF 50 400 600 59 0 8 4 18 4 1 12in 28 4mm 125499XJ 75 400 600 59 0 8 4 18 4 1 12in 28 4mm 125499XL 100 400 600 59 0 8 4 18 4 1 12in 28 4mm Volute Pi...

Страница 22: ...KIT 142157 KIT 142633 4 KIT 142137 142174 259 4SCDF 4 INCH 4SCDG 5 INCH 129994SK 5 ASSY KIT 141601 ASSY KIT 141579 KIT 142633 5 KIT 141601 142174 260 141579 002 RED 141579 004 TAN 141579 010 BROWN 141...

Страница 23: ...s Striker Plate Kit Volute Kit Striker Hardware Kit includes M10 Bolts qty 8 O ring Plate Spacing Kit includes Level 4 Cut Proof Gloves Spacer Gage Shim Stock Kit includes 0 002 Shims 12 0 004 Shims 1...

Страница 24: ...6 10in 133052TG ASSY KIT 143277TG ASSY KIT 133052TG C 143277TG C 142136 142133 1000 150mm 5 91in 133052TH ASSY KIT 143277TH ASSY KIT 133052TH C 143277TH C 142136 142133 1000 145mm 5 71in 133052TJ ASS...

Страница 25: ...F C 142126 142133 0750 170mm 6 69in 133044TG ASSY KIT 143288TG ASSY KIT 137223TG C 143288TG C 142126 142133 0750 S Impeller Trim Dia mm in Ductile Iron Slicer Blade Kit Nihard Slicer Blade Kit Kit Com...

Страница 26: ...Jumper Wire Connector Clip 24 Orange Wire Jumper Seal Kit includes Lower Volute O Ring option 1 Lower Volute O Ring option 2 Lower Volute O Ring option 3 Seal Plate upper O ring and Stator Lower O ri...

Страница 27: ...Seal Kit Bearing Kit Bearing Bracket Kit Hardware Kit Seal Plate Kit Terminal Block Kit Overhaul Kit Purchase Seal Kit and Hardware Kit Leg Kit includes 3 Legs painted attachement hardware Leg Kits Mo...

Страница 28: ...r Shaft Snap Ring Rotor Stator Motor Housing Kit includes Motor Housing painted Pipe Plug Set Cap Screw Stator Self clinching Tie Cable Cap Plug 1750 RPM Model No Motor Kit Part No SH 30N4 145663 SH 5...

Страница 29: ...127SK ASSY KIT 142633 4 KIT 3SCMPA50N4 See Motor Kit Table 138579 143127SK KIT 138583 138610 138593 138615 138613 138614 S 125506 137223TB ASSY KIT 142157 KIT 142125 AS SY KIT 143127SK ASSY KIT 142633...

Страница 30: ...133044 AS SY KIT 142157 KIT 142137 AS SY KIT 133033SK ASSY KIT 142633 4 KIT 4SCMS7554 133961 133962 138579 133033SK KIT 138584 138610 138593 138615 138613 138614 S 125506 133044 AS SY KIT 142157 KIT 1...

Страница 31: ...133052 AS SY KIT 142157 KIT 142137 AS SY KIT 133033SK ASSY KIT 142633 4 KIT 4SCDF7554 133961 133962 138579 133033SK KIT 138584 138610 138593 138615 138613 138614 S 125506 133052 AS SY KIT 142157 KIT 1...

Страница 32: ...Notes...

Страница 33: ...upport any Warranty claims This Warranty shall not apply to any product or part of product which has been subject to misuses negligence accident operation outside of our published hydraulic curve para...

Страница 34: ...Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration...

Страница 35: ..._ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating _______________...

Страница 36: ...ls installed away from turbulence YES___ NO___ Is level control operating properly YES___ NO___ Is pump fully submerged during operation YES___ NO___ Follow up Corrective Action Required YES___ NO___...

Отзывы: