TROUBLE SHOOTING CHART

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Little or no discharge

and unit will not prime

1. Casing not filled with water

2. Total head too high
3. Suction head higher than pump designed for.
4. Impeller partially or completely plugged
5. Hole or leak in suction line
6. Foot-valve too small.

7. Impeller damaged.
8. Foot-valve or suction line not submerged deep
    enough in water; pulling air.
9. Insufficient inlet pressure or suction head.

10. Suction piping too small.
11. Casing gasket leaking.
12. Suction or discharge line valves closed.
13. Piping is fouled or damaged.
14. Clogged strainer or foot-valve.
15. Incorrect engine speed.

1.Fill pump casing. Using a foot-valve will extend
   pump life and facilitate immediate priming.
2. Shorten suction head.
3. Lower suction head, install foot-valve and prime.
4. Disassemble pump and clean out impeller.
5. Repair or replace suction line.
6. Match foot-valve to piping or install one size
    larger foot-valve
7. Disassemble pump and replace impeller.
8. Submerge lower in water.

9. Increase inlet pressure by adding more water to
    tank or increasing back pressure by turning
    gate valve on discharge line partially closed
    position.
10. Increase pipe size to pump inlet size or larger.
11. Replace.
12. Open.
13. Clean or replace.
14. Clean or replace.
15. Increase speed.

Loss of suction after

satisfactory operation.

1. Air leak in suction line.
2. When unit was last turned off, water siphoned
    out of pump casing.
3. Suction head higher than pump designed for.

4. Insufficient inlet pressure or suction head.

5. Clogged foot-valve, strainer, or pump.
6. Defective wearplate(s).

1. Repair or replace suction line.
2. Refill (reprime) pump casing before restarting.

3. Lower suction head, install foot-valve and
    primer.
4. Increase inlet pressure by adding more water to
    tank or increasing back pressure by turning
    gate valve on discharge line to partially closed
    position.
5. Unclog, clear or replace as necessary.
6. Replace.

Pump overloads driver

1. Total head lower than pump rating, unit
    delivering too much water.

2. Specific gravity and viscosity of liquid being
    pumped different than the pump rating.
3. Speed to high.

1. Increase back pressure on pump by turning
    gate valve on discharge line to partially closed
    position that will not overload engine.
2. Consult factory.

3. Check and correct, lower speed.

Pump vibrates and/or

makes excessive noise

1. Mounting plate or foundation not rigid enough.
2. Foreign material in pump causing unbalance.
3. Impeller bent.
4. Cavitation present.

5. Piping not supported to relieve any strain on
    pump assembly.

1. Reinforce.
2. Disassemble pump and remove.
3. Replace impeller.
4. Check suction line for proper size and check
     valve in suction line if completely open,
     remove any sharp bends before pump and
     shorten suction line.
5. Make necessary adjustments.

Pumps runs but no fluid.

1. Faulty suction piping (air leak).
2. Pump located too far from fluid source.
3. Gate valve closed.
4. Clogged strainer.
5. Fouled foot-valve.
6. Discharge height too great.
7. Fouled impeller.
8. Faulty mechanical seal

1. Replace
2. Replace
3. Open
4. Clean or replace
5. Clean or replace
6. Lower the height
7. Clean or replace.
8. Replace

Pumps leaks at shaft

1. Worn mechanical seal.
2. Replacement seal not installed properly.

1. Replace
2. Follow Maintenance instructions carefully.

8

Manual Index

HOME

MENU

Содержание 30MU

Страница 1: ...ane Pumps Systems Inc reserves the right to change product without prior written notification Universal Drive Model 30MU BARNES 420 Third Street P O Box 603 83 West Drive Brampton Piqua Ohio 45356 060...

Страница 2: ...LE SHOOTING 8 CROSS SECTION 9 EXPLODED VIEW 10 PARTS LIST 11 RETURNED GOODS POLICY 13 START UP REPORT WARRANTY REGISTRATION Other brand and product names are trademarks or registered trademarks of the...

Страница 3: ...riate safety gear such as safety glasses when working on the pump or piping WARNING Keep clear of suction and discharge openings DO NOT insert fingers in pump with power on Always Wear Eye Protection...

Страница 4: ...CHECK VALVE Material Valve Flap Neoprene Weights Cast Iron ASTM A 48 Class 30 OPTIONAL EQUIPMENT Seal Materials Case Heater Stainless Hardware High Temperature Control Flex Coupled Assy with Base OSHA...

Страница 5: ...as near as possible to the liquid to be pumped and in no case should the pump be more than 25 feet above the surface of the liquid supply The pump should always be as level as possible All pump units...

Страница 6: ...embly onto pump body make sure that HINGE section of gasket 3 is at TOP and that LARGE weight is on PUMP SIDE of gasket E 2 Body Wear Plate and Impeller Service To clean out or repair the body 10 wear...

Страница 7: ...he front bearing 31 into position and press in place If tight use a sleeve and hammer to tap into position Replace back bearing cap 35 and grease seal 37 Do not seat bearings too tight but make sure t...

Страница 8: ...alve strainer or pump 6 Defective wearplate s 1 Repair or replace suction line 2 Refill reprime pump casing before restarting 3 Lower suction head install foot valve and primer 4 Increase inlet pressu...

Страница 9: ...9 Manual Index HOME MENU...

Страница 10: ...10 Manual Index HOME MENU...

Страница 11: ...mpeller 031266 18 2 Shim 010 001349 19 1 Shim 031 001348 20 1 Shaft Seal Carbon Ni Resist Buna N 019146 21 2 Gasket 003188 22 1 Gasket 003189 23 1 Seal Plate 011803 24 1 Slinger 005163 25 1 Bearing Ca...

Страница 12: ...NOTES 12 Manual Index HOME MENU...

Страница 13: ...nty contact your local Crane Pumps Systems Inc Distributor RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products...

Страница 14: ...ance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a...

Страница 15: ...allation Person in Charge Phone Purchased From Barnes Pumps Representative Distributor Pump Model Serial No Part Number Rotation Direction of Impeller Rotation Use C W for clockwise CC W for counter c...

Страница 16: ...hase Voltage supply at panel line connection Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 Final Check Is pump...

Страница 17: ...harge of Pump Phone Purchased from Crane Pumps Systems Representative Distributor Pumps Model Brand Part Number Trailer type Skid Mounted Contractor Trailer Highway Trailer Other Condition of Equipmen...

Страница 18: ...Date I Certify this report to be accurate Name of Start Up person Employed by Date Date and Time of Start Up Present at Start Up Engineer Operator Contractor Other To be filled out by factory Start Up...

Страница 19: ...T NO BRAND FOLD HERE IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and returned to Crane Pumps Systems Inc Warranty Service G...

Страница 20: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET P O BOX 603 PIQUA OHIO 45356 0603 U S A PLACE STAMP HERE FOLD HERE AND TAPE DO NOT STAPLE Manual Index HOME MENU...

Отзывы: