background image

3

Please Read This Before Installing Or Operating Pump. 
This information is provided for 

SAFETY and to PREVENT 

EQUIPMENT PROBLEMS

. To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result 

in personal injury or Indicates factors concerned with 
assembly, installation, operation, or maintenance which 
could result in damage to the machine or equipment if 
ignored.

CAUTION !

 Warns about hazards that can or will cause minor 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING !

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only quali

fi

 ed personnel should install, operate and repair 

pump. Any wiring of pumps should be performed by a quali

fi

 ed 

electrician.  

WARNING ! -

 To reduce risk of electrical shock, pumps 

and control panels must be properly grounded in 
accordance with the National Electric Code (NEC) or 
the Canadian Electrical Code (CEC) and all applicable 
state, province, local codes and ordinances. Improper 
grounding voids warranty.

WARNING! -

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before 
handling or servicing. Lock out power and tag.

WARNING!

 Operation against a closed 

discharge valve will cause premature bearing 
and seal failure on any pump, and on end 
suction and self priming pump the heat build 

may cause the generation of steam with resulting dangerous 
pressures. It is recommended that a high case temperature 
switch or pressure relief valve be installed on the pump body.

CAUTION! 

Pumps build up heat and pressure 

during operation-allow time for pumps to cool 
before handling or servicing. 

WARNING!

 - 

DO NOT

 pump hazardous materials 

(

fl

 ammable, caustic, etc.) unless the pump is speci

fi

 cally 

designed and designated to handle them.

CAUTION! 

- Do not block or restrict discharge hose, as 

discharge hose may whip under pressure. 

WARNING! - DO NOT

 wear loose clothing that may 

become entangled in the impeller or other moving parts. 
Always wear appropriate safety gear, such as safety 
glasses, when working on the pump or piping. 

WARNING! - 

Keep clear of suction and discharge 

openings. 

DO NOT

 insert 

fi

 ngers in pump with power 

connected.

Always wear eye protection when working on pumps.

Make sure lifting handles are securely fastened each 
time before lifting. 

DO NOT

 operate pump without 

safety devices in place. Always replace safety devices 
that have been removed during service or repair. 
Secure the pump in its operating position so it can not 
tip over, fall or slide.

DO NOT

 exceed manufacturers recommendation for 

maximum performance, as this could cause the motor 
to overheat.

WARNING!

 Cable should be protected at all times to 

avoid punctures, cut, bruises and abrasions - inspect 
frequently. Never handle connected power cords with 
wet hands.

WARNING!

 To reduce risk of electrical shock, all wiring 

and junction connections should be made per the NEC 
or CEC and applicable state or province and local 
codes. Requirements may vary depending on usage 
and location.

WARNING! 

Products Returned Must Be Cleaned, 

Sanitized, Or Decontaminated As Necessary Prior 
To Shipment, To Insure That Employees Will Not Be 
Exposed To Health Hazards In Handling Said Material. 
All Applicable Laws And Regulations Shall Apply.

 

Bronze/brass and bronze/brass 

fi

 tted pumps may 

contain lead levels higher than considered safe for 
potable water systems. Lead is known to cause cancer 
and birth defects or other reproductive harm. Various 
government agencies have determined that leaded 
copper alloys should not be used in potable water 
applications. For non-leaded copper alloy materials of 
construction, please contact factory. 

IMPORTANT! -

 Crane Pumps & Systems, Inc. is not 

responsible for losses, injury, or death resulting from a 
failure to observe these safety precautions, misuse or 
abuse of pumps or equipment.

SAFETY FIRST!

Hazardous fl uids can 
cause fi re or explo-
sions, burnes or death 
could result.

Extremely hot - Severe 
burnes can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous fl uids can Hazard-
ous pressure, eruptions or ex-
plosions could cause personal 
injury or property damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Toxic Fumes - 
Breathing can cause 
nausea, fainting or death

Eye protectiong required

Содержание 10CCE

Страница 1: ...provement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356...

Страница 2: ...10CCE 10CCE 1 15 EXPLODED VIEW 10CCE 10CCE 1 16 PARTS LIST 10CCE 10CCE 1 17 CROSS SECTION 15CCE 20CCE 25CCE 18 EXPLODED VIEW 15CCE 20CCE 25CCE 19 PARTS LIST 15CCE 20CCE 25CCE 20 RETURNED GOODS POLICY...

Страница 3: ...glasses when working on the pump or piping WARNING Keep clear of suction and discharge openings DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make...

Страница 4: ...is Tri voltage motor OPTIONAL EQUIPMENT Seal Material TEFC motors SECTION A PUMP SPECIFICATIONS 3CCE 4CCE 5CCE inches mm MODEL NO HP VOLTS PH RPM Nom ODP MOTOR DESIGN TEFC MOTOR DESIGN A DIM FULL LOAD...

Страница 5: ...ast IronASTMA 48 Class 30 MOTOR Design ODP NEMA L Single phase NEMA B Three Phase Torque Curve C Face Footed Squirrel Cage Induction Marine Duty per USCG259 and AIEEE 45 50 C Ambient Insulation Class...

Страница 6: ...LVE Material Valve Flap Neoprene Weight Cast IronASTMA 48 Class 30 MOTOR Design ODP NEMA B three phase Torque Curve C Face Footed Squirrel Cage Induction Marine Duty per USCG259 and AIEEE 45 50 C Ambi...

Страница 7: ...ght Cast IronASTMA 48 Class 30 MOTOR Design ODP NEMA B Three phase Torque Curve C Face Footed Squirrel Cage Induction Marine Duty per USCG259 and AIEEE 45 50 C Ambient Insulation Class B THREE PHASE 2...

Страница 8: ...VE Material Valve Flap Neoprene Weight Cast IronASTMA 48 Class 30 MOTOR Design ODP NEMA B three phase Torque Curve C Face Footed Squirrel Cage Induction Marine Duty per USCG259 and AIEEE 45 50 C Ambie...

Страница 9: ...leads 1 phase follow connection name plate on motor All pump units rotate clockwise when looking from the driven end of the pump Locate the pump on a firm footing to make sure the pump will not move...

Страница 10: ...To examine or replace shaft seal remove body 18 and impeller 12 as outlined in Paragraph E 2 Remove im peller shims 10 and 11 Remove rotating member of shaft seal 9 from motor shaft All of the compon...

Страница 11: ...tion head higher than pump designed for 4 Insufficient inlet pressure or suction head 5 Clogged foot valve strainer or pump 6 Defective wearplate s 1 Repair or replace suction line 2 Refill reprime pu...

Страница 12: ...12 SERIES 3CCE 3CCE 1 4CCE 4CCE 1 5CCE 5CCE 1...

Страница 13: ...13 SERIES 3CCE 3CCE 1 4CCE 4CCE 1 5CCE 5CCE 1...

Страница 14: ...3CCE 4CCE 5CCE 3 8 16 x 1 25 Lg Steel Bottom Bolts 4 002234 Cap Screw 4CCE 1 3 8 16 x 1 00 Lg Stainless 6 4 028408 Lock Washer 3 8 Steel 7 1 017432 Base 8 1 017362 Pad 9 1 012703 Shaft Seal TP CE B 10...

Страница 15: ...15 SERIES 10CCE 10CCE 1...

Страница 16: ...16 SERIES 10CCE 10CCE 1...

Страница 17: ...031 12 1 019775 Impeller 13 1 019802 Hex Hd Screw 1 2 20 x 1 00 Lg Stainless 14 2 019803 Washer Shakeproof 1 2 Stainless 15 1 019069 Volute 16 2 017715 Pin Volute 17 1 019245 Gasket Volute 18 1 019135...

Страница 18: ...18 SERIES 15CCE 20CCE 25CCE...

Страница 19: ...19 SERIES 15CCE 20CCE 25CCE...

Страница 20: ...1 090050TB Impeller 20CCE 1 051102 Impeller 25CCE 13 1 019802 Hex Hd Screw 1 2 20 x 1 00 Lg Stainless 14 2 019803 Washer Shakeproof 1 2 Stainless 1 070089 Washer 25CCE Only 15 1 018883 Volute 15CCE 20...

Страница 21: ...PXVW EH VLJQHG E RXU DXWKRUL HG UHSUHVHQWDWLYH XH WR LQDFFXUDFLHV LQ HOG WHVWLQJ LI D FRQ LFW DULVHV EHWZHHQ WKH UHVXOWV RI HOG WHVWLQJ FRQGXFWHG E RU IRU XVHU DQG ODERUDWRU WHVWV FRUUHFWHG IRU HOG SH...

Страница 22: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by t...

Отзывы: