background image

1

General Safety Information

Before installation, read the following 
instructions  carefully.  Failure  to 
follow 

instruction 

and 

safety 

information  could  cause  serious 
bodily  injury,  death  and/or  property 
damage.  Each  Barmesa  product  is 
carefully  inspected  to  insure  proper 
performance. Closely following these 
instructions  will  eliminate  potential 
operating  problems,  assuring  years 
of trouble-free service. 

IMPORTANT! - Barmesa Pumps is not 
responsible  for  losses,  injury  or 
death  resulting  from  failure  to 
observe  these  safety  precautions, 
misuse,  abuse  or  misapplication  of 
pumps or equipment.

Installation, wiring, and 

junction  connections  must  be  in 
accordance with the National Electric 
Code and all applicable state and local 
codes.  Requirements  may  var y 
depending on usage and location.

WARNING

I n s t a l l a t i o n   a n d 

servicing  is  to  be  conducted  by 
qualified personnel only.

WARNING

D o   n o t

  p u m p 

hazardous  materials  (flammable, 
caustic,  etc.)  or  use  these  pumps  in 
water  over  160  °F. 

Do  not

  exceed 

m a n u f a c t u r e r s   r e c o m m e n d e d 
maximum performance, as this could 
cause the motor to overheat.

WARNING

C a r e f u l l y   r e a d 

instruction  manuals  supplied  with 
motor  or  engine  before  operating or 
servicing.

WARNING

A L L   R E T U R N E D 
P R O D U C T S   M U S T   B E 
CLEANED,  SANITIZED,  OR

D E CO N TA M I N AT E D   P R I O R   TO 
SHIPMENT, TO INSURE EMPLOYEES 
WILL NOT BE EXPOSED TO HEALTH 
HAZ ARDS  IN  HANDLING  SAID 
MATERIAL. ALL APPLICABLE LAWS 
AND REGULATIONS SHALL APPLY.

Keep  clear  of  suction  and 
discharge  openings.  Do  not 
insert  fingers  in  pump  with

power  connected;  the  impeller  can 
cause serious injury.

Always  wear  eye  protection 
when working on pumps. Do 
not wear loose clothing that

may  become  entangled  in  moving 
parts.

Pumps  build  up  heat 
and  pressure  during 
operation.  Allow  time 
f o r   p u m p s   t o   c o o l

DANGER

before  handling  or  servicing  the 
p u m p   o r   a n y   a c c e s s o r y   i t e m s 
associated with or near the pump. Do 
not  block  or  restrict  the  discharge 
pipe/hose.

T h i s   p u m p   i s   n o t 

i n t e n d e d   f o r   u s e   i n 
swimming  pools  or  water 
installations  where  there  is

DANGER

human contact with pumped fluid.

Risk of electric shock. To 

reduce risk of electric shock, 
always  disconnect  pump 
from  power  source  before

DANGER

handling any aspect of the pumping 
system.

 Lock out power and tag.

 Indicates a potentially 

hazardous  situation  which,  if  not 
avoided,  MAY  result  in  minor  or 
moderate injury.

CAUTION

Do  not

  lift,  carry  or 

hang pump by the electrical 
c a b l e s .   D a m a g e   t o   t h e 
electrical  cables  can  cause

DANGER

shock, burns  or death. 

Never

 handle 

connected  power  cords  with  wet 
hands. Use appropriate lifting device.

 Indicates  an  immi-

nently hazardous situation which, if 
not avoided, MAY result in death or 
serious injury.

WARNING

 Indicates  an  immi-

nently hazardous situation which, if 
not avoided, WILL result in death or 
serious injury.

DANGER

Failure  to  permanently 

ground the pump, motor and 
controls  before  connecting 
to  power  can  cause  shock,

DANGER

burns or death.

IMPORTANT!  -  Prior  to  installation, 
record  Model  Number,  Serial,  Amps, 
Voltage,  Phase  and  HP  from  pump 
name  plate  for  the  future  reference. 
Also  record  the  Voltage  and  current 
readings at startup:

Model Number: _____________________

Serial: _____________________________

PHASE: ______ HP: __________________

3 Phase Models

Amps L1-2:

Volts L1-2:

Amps L2-3:

Volts L2-3:

Amps L3-1:

Volts L3-1:

barmesa.com

Содержание BCS Series

Страница 1: ...ion Centrifugal Stainless Steel Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump Last update 07 15 2021 BCS series 0 5 HP 1750 RPM 0 75 3 HP 3500 RPM BCSF seri...

Страница 2: ...impeller can causeseriousinjury Always wear eye protection when working on pumps Do not wear loose clothing that may become entangled in moving parts Pumps build up heat and pressure during operation...

Страница 3: ...mediatecoupling 4BCS SERIES 2 50 1 59 SINGLE PHASE ONLY 6 31 MAX 6 50 2 50 L 1 NPT OPTIONAL 2 88 3 38 SUCTION DISCHARGE W C MAX 0 41 DIA HOLES 4 PLACES 3 50 X 4 12 2 94 2 94 6 75 4 88 MAX R 2 66 Dimen...

Страница 4: ...protectionmustbeprovided HARDWARE AISI304stainlesssteel PAINT Solventbasedenamel onlyintermediatecoupling 4BCSF SERIES AB APPROX Z X E E A D G APPROX MAX 17 8 W BG C MAX O MAX F F B H HOLES 4 R L D Mo...

Страница 5: ...M A AB B All dimensions are in inches and weight in pounds Do not use for construction purposes Pumps will be shipped with top vertical discharge position as standard For other orientations remove cas...

Страница 6: ...educe friction on the suction side A successful operation depends on the calculation of the friction loss in the suction considering acceptable limits The minimum suction pipe size to use can be deter...

Страница 7: ...d by using a smaller diameter pipe a larger diameter discharge pipe is commonly used than the required by the volute or body Figure 2 Wrong installation Without strainer Vortex D Too much height Less...

Страница 8: ...MPORTANT Do not operate pump without priming first Operating dry will damage seal 4Pre Operation 1 Check Voltage and Phase Compare the voltage and phase information stamped on the pump name plate 2 Ch...

Страница 9: ...en the pump for inspection or cleaning DO NOT remove the seal only remove the spring if the impeller had to be removed Once a seal has been in operation it is very difficult that when removing and rea...

Страница 10: ...54 1 21 9 7 28 1 86 0 6 180 757 66 3 26 7 8 9 2 27 0 73 0 3 200 833 80 32 2 10 07 2 72 0 87 0 35 220 908 95 38 1 12 6 3 21 1 03 0 41 240 984 111 44 5 14 7 3 74 1 2 0 48 260 1060 128 51 3 16 9 4 3 1 38...

Страница 11: ...75 3 36 STANDARD 45 ELBOW 0 38 0 54 0 61 0 77 0 92 1 15 1 53 1 83 2 29 STANDARD TEE 1 68 2 29 2 75 3 36 4 28 5 19 6 71 8 23 10 1 ANGLE GLOBE VALVE OPEN 3 97 5 49 6 71 8 23 10 7 12 2 16 8 21 3 25 9 GL...

Страница 12: ...11 Spare Parts To request a replacement please provide the model and serial number as shown on the nameplate and the description and part number as shown in the parts list 4BCS barmesa com...

Страница 13: ...ller BCS 3 94 03140237I Impeller BCS 3 75 03140237J Impeller BCS 3 50 5 03180031 Seal plate BCS 1 CF8M 6 30400840B Shaft sleeve BCS 1 316 SS 7 31030287 Mechanical seal 7 8 1 0114SVP6SS 8 30400530 Base...

Страница 14: ...ANICAL SEAL ROTATORY PART MECHANICAL SEAL MECHANICAL SEAL STATIONARY PART STATIONARY PART MECHANICAL SEAL STATIONARY PART To request a replacement please provide the model and serial number as shown o...

Страница 15: ...teel 17 92010040H Housing gasket 2 257 1 Viton 18 92010014 Deflector washer 1 Buna N 19 94010061E Identification plate BCSF 1 Aluminum 20 91010192 Rivet 001628 SS 2 Stainless steel ITEM PART DESCRIPTI...

Страница 16: ...1 91010345C Hex screw 3 8 x 1 2 304 SS 12 91010413 Hex screw 3 8 x 1 4 Steel 13 91010012 Spring washer 3 8 4 Steel 14 91010061 Spring washer 3 8 10 304 SS 15 92010030G Impeller gasket 0 025 2 Viton 16...

Страница 17: ...n on the nameplate and the description and part number as shown in the parts list 4BCSF AK 8 MECHANICAL SEAL MECHANICAL SEAL ROTATORY PART ROTATORY PART MECHANICAL SEAL ROTATORY PART MECHANICAL SEAL M...

Страница 18: ...sket 2 265 1 Viton 18 92010014 Deflector washer 1 Buna N 19 94010061E Identification plate BCSF 1 Aluminum 20 91010192 Rivet 001628 SS 2 Stainless steel 4BCSF 1 x 2 8 with flange 8 ITEM PART DESCRIPTI...

Страница 19: ...mping capacity is not too much The pump is operating in the range of NPSHR If reducing flow makes the noise gone then the problem is in the point above partially close the discharge valve The bearings...

Страница 20: ...19 barmesa com...