Before installation, read the following 

instructions  carefully.  Failure  to 
follow 

instruction 

and 

safety 

information  could  cause  serious 

bodily  injury,  death  and/or  property 

damage.  Each  Barmesa  product  is 

carefully  inspected  to  insure  proper 
performance. Closely following these 
instructions  will  eliminate  potential 

operating  problems,  assuring  years 
of trouble-free service. 

01

General Safety Information

IMPORTANT! - Barmesa Pumps is not 
responsible  for  losses,  injury  or 
death  resulting  from  failure  to 
observe  these  safety  precautions, 
misuse,  abuse  or  misapplication  of 
pumps or equipment.

Installation,  wiring,  and 

junc tion  connec tions  must  be  in 
accordance  with  the  National  Electric 
Code  and  all  applicable  state  and  local 
codes. Requirements may vary depending 
on usage and location.

WARNING

I n s t a l l a t i o n   a n d 

servicing  is  to  be  conducted  by 

qualified personnel only.

WARNING

D o   n o t

  u s e   t h e s e 

pumps  in  water  over  104º  F. 

Do  not

 

exceed manufacturers recommended 
maximum performance, as this could 
cause the motor to overheat.

WARNING

Ground  Fault  Circuit 

Interrupter  (GFCI)  to  be  used  with 

plug-in type power cord.

WARNING

A L L   R E T U R N E D 
P R O D U C T S   M U S T   B E 

CLEANED,  SANITIZED,  OR

DECONTAMINATED  PRIOR  TO 
SHIPMENT, TO INSURE EMPLOYEES 
WILL NOT BE EXPOSED TO HEALTH 

HAZARDS  IN  HANDLING  SAID 
MATERIAL. ALL APPLICABLE LAWS 
AND REGULATIONS SHALL APPLY.

Keep  clear  of  suction  and 

discharge  openings.  Do  not 

insert  fingers  in  pump  with

power connected; the rotating cutter 

and/or  impeller  can  cause  serious 

injury.

Always  wear  eye  protection 

when working on pumps. Do 
not wear loose clothing that

may  become  entangled  in  moving 

parts.

Pumps  build  up  heat 
and  pressure  during 

operation.  Allow  time 

fo r   p u m p s   t o   c o o l

DANGER

before  handling  or  servicing  the 
pump  or  any  accessor y  items 

associated with or near the pump.

T h i s   p u m p   i s   n o t 

i n t e n d e d   f o r   u s e   i n 

swimming  pools  or  water 
installations  where  there  is

DANGER

human contact with pumped fluid.

Risk of electric shock. To 

reduce risk of electric shock, 

always  disconnect  pump 
from  power  source  before

DANGER

handling any aspect of the pumping 
system.

 Lock out power and tag.

Do  not

  lift,  carry  or 

hang pump by the electrical 

c a b l e s.   D a m a g e   to   t h e 

electrical  cables  can  cause

DANGER

shock, burns or death. 

Never

 handle 

connected  power  cords  with  wet 

hands. Use appropriate lifting device.

S u m p   a n d   s e w a g e 

pumps often handle materials which 

could  cause  illness  or  disease.  Wear 
adequate  protective  clothing  when 

working  on  a  used  pump  or  piping. 
Never enter a basin after it has been 

used.

WARNING

Failure  to  permanently 

ground the pump, motor and 

controls  before  connecting 

to  power  can  cause  shock,

DANGER

burns or death.

These pumps are not to 

be  installed  in  locations 
classified  as  hazardous  in 

accordance with the National

Electric Code, ANSI/NFPA 70.

DANGER

The  Uniform  Plumbing 

Code  (UPC)  states  that  sewage 
systems shall have an audio and visual 
alarm that signals a malfunction of the 

systems,  that  are  required  to  reduce 

the potencial for property damage.

WARNING

1 Phase Models

Amps:

Volts:

3 Phase Models

Amps L1-2:

Volts L1-2:

Amps L2-3:

Volts L2-3:

Amps L3-1:

Volts L3-1:

Model Number: _____________________

Serial: ____________

PHASE: ______ HP: __________________

IMPORTANT!  -  Prior  to  installation, 
record  Model  Number,  Serial,  Amps, 

Voltage,  Phase  and  HP  from  pump 
name  plate  for  the  future  reference. 

Also  record  the  Voltage  and  Current 
Readings at Startup:

WARNING

 "Danger" indicates an 

imminently  hazardous  situation 

which, if not avoided, WILL result in 
death or serious injury.

"Warning"  indicates 

an  imminenty  hazardous  situation 
which, if not avoided, MAY result in 
death or serious injury.

"Caution"  indicates  a 

potentially  hazardous  situation 
which, if not avoided, MAY result in 

minor or moderate injury.

DANGER

CAUTION

barmesapumps.com

Содержание 8BSE-HADS

Страница 1: ...ration Maintenance Manual Submersible Non Clog Sewage Pumps 8BSE HADS 30 40 50 60 75 1150 RPM 100 125 200 1750 RPM IMPORTANT Read all instructions in this manual before operating or servicing a pump b...

Страница 2: ...ry items associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric sh...

Страница 3: ...NG Bronze MOTORHOUSING CastironASTMA 48class30 SEALPLATE CastironASTMA 48class30 IMPELLER Castiron ASTM A 48class 3vanes closed withabronzewearringandvanesonbackside 30 SHAFT 416seriesstainlesssteel S...

Страница 4: ...o accommodate the additional backflow volume Pumps are most commonly installed in simplex or duplex stations or basins with a slide rail system Barmesa SRC which allows the pump s to be installed or r...

Страница 5: ...tion as viewed from motor end or opposite to impeller rotation Impeller rotation is counter clockwise as viewed from bottom of pump 3 Name Plate Record the information from the pump name plate to draw...

Страница 6: ...screws 2 and torque to 24 ft lbs Check for free rotation of motor and impeller Locate impeller washer 8 on shaft apply thread lock primer such as LOCTITE Primer T let set per manufacturer s direction...

Страница 7: ...GASKET 1 4 03020022 ADAPTER 1 5 91010396 SOCKET HD SCREW 5 8 x 1 STAINLESS 12 6 30400105 MOTOR ADAPTER 1 7 03140107 IMPELLER 1 8 30400415 IMPELLER WASHER 1 9 91010064 LOCKWASHER 3 4 STAINLESS 1 10 910...

Страница 8: ...supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with flexible...

Страница 9: ......

Страница 10: ......

Отзывы: