background image

Impeller and Volute -

 Install impeller 

(29)  by  appling  a  thin  film  of  oil  to 

motor  shaft  and  slide  impeller 
straight onto shaft, keeping keyways 
lined  up.  Drive  key  (13)  into  keyway. 

Locate  washer,  apply  thread  lock 
primer (such as Loctite® Primer T), let 

set  per  manufacturer's  directions. 
Apply  thread  locking  compound  to 
threads on cap screw, and thread into 

shaft and torque to 35 ft/lbs. 

Place gasket (32) on volute and install 

impeller  and  motor  assembly  over 

studs  and  onto  volute  (34).  Apply 

thread locking compound to threads 
of  studs  (25)  and  thread  nuts  (26) 

onto  studs  and  torque  to  24  ft/lbs. 

Check  for  binding  by  rotating 

impeller.  Clearance  between  the 

impeller  and  volute  should  be 
approximately 0.012 inch.

08

Service

G T1 T7 T2 T8 T3 T9 T4 T5 T6

G L1

L2

L3

G

RE

EN

BL

AC

K

RE

D

W

H

IT

E

MOTOR LEADS

THREE-PHASE 230V AC

Cable

Motor Lead Number

Green

Green

Black

1 and 7

Red

2 and 8

White

3 and 9

4, 5 and 6 

together

Figure 5

T2 T3 T4 T7 T5 T8 T6 T9

G

L2 L3

RE

D

W

H

IT

E

MOTOR LEADS

T1

L1

BL

AC

K

G

G

G

RE

EN

THREE-PHASE 460V AC

Cable

Motor Lead Number

Green

Green

Black

1

Red

2

White

3

4 and 7 together
5 and 8 together
6 and 9 together

Figure 5

G

G

GREEN

P1 P2

L1

BLA

CK

L2

WHITE

THERMOSTAT

N/C

WHITE

WHITE

N/O

S1 S2

L3

RED

L4

ORANGE

SE

N

SO

R

SE

N

SO

R

ORANGE

ORANGE

TEMPERATURE

SENSOR

MOISTURE

SENSOR

CONTROL CABLE

Control Cable

Lead Number

Black

L1 (Temperature)

White

L2 (Temperature)

Red

L3 (Moisture)

Orange

L4 (Moisture)

Green

Ground

Figure 5

barmesapumps.com

Содержание 4BSE-HLDS Series

Страница 1: ...llation Operation Maintenance Manual Submersible Solids Handling Pumps 4BSE HLDS 7 5 11 3 15 HP 1750 RPM IMPORTANT Read all instructions in this manual before operating or servicing a pump barmesapump...

Страница 2: ...ry items associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric sh...

Страница 3: ...EMA B oil filled Requires overload protection to be included in controlpanel ClassFinsulation MOISTURESENSOR Normallyopen N O included requiresrelayincontrolpanel TEMPERATURESENSOR Normallyclosed N C...

Страница 4: ...asin to accommodate the additional backflow volume Pumps are most commonly installed in simplex or duplex stations or basins with a slide rail system Barmesa SRC which allows the pump s to be installe...

Страница 5: ...wer and observe the kickback Kickback should always be in a counter clockwise direction as viewed from motor end or opposite to impeller rotation Impeller rotation is counter clockwise as viewed from...

Страница 6: ...in the top of the housing to compensate for oil expansion Reassemble the o ring 5 and conduit box 4 to motor housing 3 Apply thread locking compound to cap screws 6 and place into holes and torque to...

Страница 7: ...Remove upper bearing 2 with a wheel puller if damaged or worn Vertically lift stator 1 from rotor shaft Inspect windings for shorts and resistance Test the temperature sensors by checking for continui...

Страница 8: ...rd stationary member and align holes for cap screws 25 Conduit Box Assembly Check power 35 and control cables 36 for crackes or damage and replace complete conduit box 4 if required See Figure 4 Bring...

Страница 9: ...Clearance between the impeller and volute should be approximately 0 012 inch 08 Service G T1 T7 T2 T8 T3 T9 T4 T5 T6 G L1 L2 L3 GREEN BLACK RED WHITE MOTOR LEADS THREE PHASE 230V AC Cable Motor Lead...

Страница 10: ...Figure 6 09 Repair Parts barmesapumps com For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List...

Страница 11: ...esapumps com For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List 40 40 91010433 91010433 91010433 03140078C 0314007...

Страница 12: ...supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with flexible...

Страница 13: ......

Страница 14: ......

Отзывы: