background image

02

Specifications & Dimensions

DISCHARGE: 

   

SPHERICAL SLD HNDLG: 
LIQUID TEMPERATURE:

  

VOLUTE:

  

MOTOR HOUSING:

    

SEAL PLATE:

    

IMPELLER:

 

 

SHAFT: 

 

SQUARE RINGS:

 

PAINT:

  

SEAL:   

DIAPHRAGM:

   

HARDWARE:

   

CORD ENTRY: 

 

UPPER BEARING:

 

LOWER BEARING:

 

MOTOR:

 

MOISTURE SENSOR:

 

4", 125lb, flange horizontal.
3"
104° F (40° C) max.
Cast iron ASTM A-48 class 30.
Cast iron ASTM A-48 class 30.
Cast iron ASTM A-48 class 30.
2 vane, open, with vanes on back side. Cast iron ASTM A-48 class 30.
416 series stainless steel.
Buna-N.
Air dry enamel, water based.
Double mechanical, oil filled chamber. Silicon carbide outboard, carbon 

ceramic inboard seal, 

Buna-N elastomer and

 stainless steel hardware.

Buna-N.
300 series stainless steel.
40 ft of neoprene cord SJO 14/3, sealed against moisture.
Ball, single row, oil lubricated, for radial load.
Ball, single row, oil lubricated, for radial and thrust load.

Single  phase:

  NEMA  L,  permanent  split  capacitor,  oil  filled,  with  overload 

protection in motor.

Three phase:

 NEMA B, oil filled. Requires overload protection to be included in 

control panel. Class F insulation.
Normally open (N/O) included, requires relay in control panel.

TEMPERATURE SENSOR

Normally closed (N/C) included, requires relay in control panel.

OPTIONAL EQUIPMENT:

 

Additional cord, tungsten carbide seal, slide rail coupling (SRC-4).

MODEL

HP VOLTS PHASE

RPM

(Nominal)

MAX

AMPS

LOCKED

ROTOR AMPS

NEMA

CODE

CORD

SIZE

CORD

TYPE

CORD

O. D.

WEIGHT

(pounds)

4BSE452DS

4.5

230

1

1750

26

59

A

10/4

SO

0.78"

287

4BSE453DS

4.5

230

3

1750

17.6

56

E

10/4

SO

0.78"

280

4BSE454DS

4.5

460

3

1750

8.8

28

E

10/4

SO

0.78"

280

4BSE752DS

7.5

230

1

1750

39

96

A

10/4

SO

0.78"

315

4BSE753DS

7.5

230

3

1750

23.6

80

D

10/4

SO

0.78"

309

4BSE754DS

7.5

460

3

1750

11.8

40

D

10/4

SO

0.78"

309

4BSE1133DS 11.3

230

3

1750

28.4

126

D

10/4

SO

0.78"

340

4BSE1134DS 11.3

460

3

1750

14.2

63

D

10/4

SO

0.78"

340

4BSE1503DS 15

230

3

1750

40

160

D

10/4

SO

0.78"

399

4BSE1504DS 15

460

3

1750

20

80

D

10/4

SO

0.78"

399

The moisture cord and/or temperature cord is size 18/5, type SO, Ø0.485", for all models.

barmesapumps.com

13.66"

13.66"

20.5"

20.5"

16.5"

16.5"

6.5"

6.5"

35"

35"

5.5"

5.5"

Содержание 4BSE-DS Series

Страница 1: ...lation Operation Maintenance Manual Submersible Solids Handling Pumps 4BSE DS 4 5 7 5 11 3 15 HP 1750 RPM IMPORTANT Read all instructions in this manual before operating or servicing a pump barmesapum...

Страница 2: ...ry items associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric sh...

Страница 3: ...oad protection to be included in controlpanel ClassFinsulation Normallyopen N O included requiresrelayincontrolpanel TEMPERATURESENSOR Normallyclosed N C included requiresrelayincontrolpanel OPTIONALE...

Страница 4: ...lex stations or basins with a slide rail system Barmesa SRC which allows the pump s to be installed or removed without requiring personnel to enter the station or resting on the basin floor Discharge...

Страница 5: ...phase information stamped on the pump name plate 2 Check Pump Rotation Improper motor rotation can result in poor pump performance and can damage the motor and or pump Check rotation on three phase un...

Страница 6: ...duit box 4 to motor housing 3 Apply thread locking compound to cap screws 6 and place into holes and torque to 15 ft lbs Oil Replacement Seal Chamber Refill chamber completely full with new cooling oi...

Страница 7: ...wave washer Remove upper bearing 2 with a wheel puller if Vertically lift stator 1 from rotor shaft Inspect windings for shorts and resistance Test the temperature sensors by checking for continuity...

Страница 8: ...4 if required See Figure 4 Bring motor wires through opening in top of motor housing 3 check sleeving and replace if damaged Position square ring 5 in conduit box 4 and reconnect leads using connector...

Страница 9: ...GREEN BLACK RED WHITE MOTOR LEADS THREE PHASE 230V AC Cable Motor Lead Number Green Green Black 1 and 7 Red 2 and 8 White 3 and 9 4 5 and 6 together Figure 5 T2 T3 T4 T7 T5 T8 T6 T9 G L2 L3 RED WHITE...

Страница 10: ...Figure 6 09 Repair Parts barmesapumps com For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List...

Страница 11: ...t For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List 40 40 4 5 H P SINGLE PHASE 230 7 5 H P SINGLE PHASE 230 barme...

Страница 12: ...supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with flexible...

Страница 13: ......

Страница 14: ......

Отзывы: