Barmesa Pumps 2SEV512 Скачать руководство пользователя страница 5

04

Installation & Service

Both  a  check  valve  and  a  shut-off 

valve  are  recommended  for  each 
pump.  The  check  valve  is  used  to 
prevent backflow into the sump. The 

shut-off  valve  is  used  to  manually 

stop  system  flow  during  pump 

servicing.

Electrical Connections

Power cable:

The  power  cable  mounted  to  the 
pump  must  not  be  modified  in  any 
way. This pump  is provided  with  a 3 

wire  cord  and  3  prong  grounded 
plug that must be connected into a 3 

wire  grounded  Ground  Fault 
receptacle. Do not bypass grounding 
wires or remove ground prongs from 

plug.  This  pump  requires  separate, 

properly fused and grounded branch 
circuit.  Use  of  a  ground  fault  circuit 

interrupter  (GFCI)  is  strongly 
recommended. 

The electrical outlet or panel shall be 
within  the  length  limitations  of  the 
pump power cord, and at least 4 feet 

above  floor  level  to  minimize 

possible 

hazards 

from 

flood 

conditions. Do Not use an extension 

cord.

IF  USED  with  Control  Panel  - 

Any 

splice  between  the  pump  and  the 
control  panel  must  be  made  in 

accordance with the electric codes. It 
is recommended that a junction box, 
if  used,  be  mounted  outside  the 

sump or be of at a minimum NEMA 4 
construction if located within the wet 
well. 

DO  NOT  USE  THE  POWER 

CABLE TO  LIFT  PUMP

.  Always  rely 

upon  a  Certified  Electrician  for 
installation. 

This  means  that  the  overload 

protector  will  trip  out  and  shut  the 
pump off if the windings become too 
hot,  or  the  load  current  passing 

through them becomes too high.

IMPORTANT! -

 The overload will then 

automatically  reset  and  start  the 
pump  up  after  the  motor  cools  to  a 

safe  temperature.  In  the  event  of  an 

overload, the source of this condition 

should be determined and corrected 
immediately. 

D O   N O T   L E T   T H E 

P U M P   C YC L E   O R   R U N   I F   A N 
OVERLOAD CONDITION OCCURS.

WARNING

If  current  through  the  temperature 

sensor  exceeds  the  values  listed,  an 
intermediate  control  circuit  relay 
must  be  used  to  reduce  the  current 
or the sensor will not work properly.

TEMPERATURE SENSOR ELECTRICAL 

RATINGS

Volts

Continuous

Amperes

Inrush

Amperes

110-120

3.00

30.0

220-240

1.50

15.0

Wire Size:

If  longer  power  cable  is  required 

consult  a  qualified  electrician  for 

proper wire size.

Pre-Operation

1.

   C

heck  Voltage  and  Phase  - 

Compare  the  voltage  and  phase 

information  stamped  on  the 
pump name plate.

2.

   Check 

Pump Rotation -

 Improper 

motor rotation can result in poor 

pump  performance  and  can 
damage  the motor and/or  pump. 

Incorrect rotation for Single-Phase 
pumps is unlikely. If the rotation is 

incorrect contact factory.

3.

   N

ame  Plate  - 

Record  the 

information from the pump name 

plate  to  drawing  in  front  of 
manual for future reference.

4.

   I

nsulation  Test  - 

An  insulation 

(megger) 

test 

should 

be 

performed  on  the  motor.  Before 

the pump is put into service. The 

resistance  values  (ohms)  as  well 
as the voltage (volts) and current 

(amps) should be recorded.

5.

   P

ump-Down Test - 

Be sure pump 

has been properly wired, lowered 

into the basin, sump or lift station, 
check  the  system  by  filling  with 

liquid and allowing the pump to 

operate  through  its  pumping 

cycle. The time needed to empty 

the  system,  or  pump-down  time 
along  with  the  volume  of  water, 
should be recorded.

No  lubrication  or  maintenance  is 

required.  Perform  the  following 
checks when pump is removed from 
operation 

or 

when 

pump 

performance deteriorates:

Maintenance

a)

   I

nspect  motor  chamber  for  oil 

level and contamination.

b)

   I

nspect  impeller  and  body  for 

excessive build-up or clogging.

c)   I

nspect motor, bearings and shaft 

seal for wear or leakage.

Overload Protection:

Single Phase

 - The stator in-winding 

overload protector used is referred to 
as an inherent overheating protector 
and operates on the combined effect 

of temperature and current.

Cooling  Oil  - 

Anytime  the  pump  is 

removed from operation, the cooling 

oil  in  the  motor  housing  should  be 
checked  visually  for  oil  level  and 

contamination.

Servicing

To check oil, set unit upright. Remove 

pipe plug from housing.

barmesapumps.com

Содержание 2SEV512

Страница 1: ...Installation Operation Maintenance Manual Submersible Sewage Pumps 2SEV512 0 5 3500 RPM IMPORTANT Read all instructions in this manual before operating or servicing a pump barmesapumps com...

Страница 2: ...ociatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To reduc...

Страница 3: ...lerow oillubricated forradialload LOWERBEARING Ball singlerow oillubricated forradialandaxialloads MOTOR NEMA L single phase permanent split capacitor 115 volts 60 Hz 3500 RPM oil filled withoverloadp...

Страница 4: ...is in the Off mode By adjusting the cord tether the control level can be changed Typical Discharge Pipe Mounted Level Control DISCHARGE VENT INLET GATE VALVE UNION CHECK VALVE Drill dia vent hole to...

Страница 5: ...ontrol circuit relay must be used to reduce the current or the sensor will not work properly TEMPERATURE SENSOR ELECTRICAL RATINGS Volts Continuous Amperes Inrush Amperes 110 120 3 00 30 0 220 240 1 5...

Страница 6: ...arefully inspected for leaks at the shaft seal cable assembly square ring and pipe plug before refilling with oil To locate the leak perform a pressure test After leak is repaired dispose of old oil p...

Страница 7: ...ing into seal plate until seated 11 Clean the threads with thread locking compound cleaner Apply removable Loctite 242 or equivalent to shaft threads Screw impeller onto the shaft hand tight while usi...

Страница 8: ...07 Repair Parts barmesapumps com 2SEV512 For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List...

Страница 9: ...1 9 Stator 1 10 Rotor 1 11 Lower bearing plate 1 HT200 12 Bearing 6203 Z3 1 13 Mechanical seal 1 CC SiC 14 Impeller 1 HT200 15 Hex socket cap screws 1 4 20UNCx28 5 304 16 Casing 1 HT200 17 Handle 1 30...

Страница 10: ...supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with flexible...

Страница 11: ......

Страница 12: ......