Barmesa Pumps 2SEV512 Скачать руководство пользователя страница 3

02

Specifications & Dimensions

DISCHARGE: 

   

 

2" NPT, female, vertical.

SPH SLD HNDLG: 

 

 

2"

LIQUID TEMPERATURE:

  

104 °F (40 °C) max.

VOLUTE:

  

 

 

Cast iron ASTM A-48 class 30.

MOTOR HOUSING:

    

Cast iron ASTM A-48 class 30.

IMPELLER:

 

 

 

Vortex. Cast iron ASTM A-48 class 30, dynamically balanced, ISO G6.3.

SHAFT: 

 

 

 

416 series stainless steel.

O-RINGS:

 

 

 

Square shaped Buna-N.

PAINT:

  

 

 

Air dry enamel, water based.

SEAL:   

 

 

Single mechanical, oil filled chamber. Carbon / ceramic / Buna-N, with stainless steel 

hardware.

HARDWARE:

   

 

300 series stainless steel.

CORD ENTRY: 

 

 

20 ft of neoprene cord SJTOW 16/3, sealed against moisture.

UPPER BEARING:

 

 

Ball, single row, oil lubricated, for radial load.

LOWER BEARING:

 

 

Ball, single row, oil lubricated, for radial and axial loads.

MOTOR:

 

 

 

NEMA L, single phase, permanent split capacitor, 115 volts, 60 Hz, 3500 RPM, oil 

filled, with overload protection in motor.

OPTIONAL EQUIPMENT:

 

Additional cord, slide rail coupling (SRC-2).

A = Automatic Float Switch, VF = Automatic Vertical Float Switch.

MODEL

PART No.

HP VOLTS PHASE

RPM

(Nominal)

MAX

AMPS

LOCKED

ROTOR AMPS

CORD

SIZE

CORD

TYPE

WEIGHT

(pounds)

2SEV512

62180405

0.5

115

1

3500

10.2

16

16/3 SJTOW

51

2SEV512A

62180406

0.5

115

1

3500

10.2

16

16/3 SJTOW

53

2SEV512VF 62180407

0.5

115

1

3500

10.2

16

16/3 SJTOW

53

4.47"

4.47"

15"

15"

6.45"

6.45"

3.23"

3.23"

9.43"

9.43"

4.82"

4.82"

2" NPT

2" NPT

1.22"

1.22"

barmesapumps.com

Содержание 2SEV512

Страница 1: ...Installation Operation Maintenance Manual Submersible Sewage Pumps 2SEV512 0 5 3500 RPM IMPORTANT Read all instructions in this manual before operating or servicing a pump barmesapumps com...

Страница 2: ...ociatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To reduc...

Страница 3: ...lerow oillubricated forradialload LOWERBEARING Ball singlerow oillubricated forradialandaxialloads MOTOR NEMA L single phase permanent split capacitor 115 volts 60 Hz 3500 RPM oil filled withoverloadp...

Страница 4: ...is in the Off mode By adjusting the cord tether the control level can be changed Typical Discharge Pipe Mounted Level Control DISCHARGE VENT INLET GATE VALVE UNION CHECK VALVE Drill dia vent hole to...

Страница 5: ...ontrol circuit relay must be used to reduce the current or the sensor will not work properly TEMPERATURE SENSOR ELECTRICAL RATINGS Volts Continuous Amperes Inrush Amperes 110 120 3 00 30 0 220 240 1 5...

Страница 6: ...arefully inspected for leaks at the shaft seal cable assembly square ring and pipe plug before refilling with oil To locate the leak perform a pressure test After leak is repaired dispose of old oil p...

Страница 7: ...ing into seal plate until seated 11 Clean the threads with thread locking compound cleaner Apply removable Loctite 242 or equivalent to shaft threads Screw impeller onto the shaft hand tight while usi...

Страница 8: ...07 Repair Parts barmesapumps com 2SEV512 For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List...

Страница 9: ...1 9 Stator 1 10 Rotor 1 11 Lower bearing plate 1 HT200 12 Bearing 6203 Z3 1 13 Mechanical seal 1 CC SiC 14 Impeller 1 HT200 15 Hex socket cap screws 1 4 20UNCx28 5 304 16 Casing 1 HT200 17 Handle 1 30...

Страница 10: ...supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with flexible...

Страница 11: ......

Страница 12: ......

Отзывы: