BARIX IPAM 400 Скачать руководство пользователя страница 9

Preliminary Development 

 BARIX IP AUDIO MODULE 400 

 V 02.20 

 9.April.2018 

 

Connectors

 

9

 

 

Connectors 

Connector placement 

 

 

For connector placement (and type) please refer to the mechanical 

drawing in previous chapter. 

 

Connector pin out 

J1 pin out (analog audio 
input and output) 

 

 

Pin # 

Name 

Type  Description (usage) 

MICIN1N 

AI 

Mic balanced negative input (unbal. Mic / line: connect 
1uF to GND) 

MICIN1P 

AI 

Mic positive input or Left channel audio input (for line 
see remark above) 

AGND 

Audio Ground 

INR 

AI 

Right channel audio input 

LINEOUTL 

AO 

Left channel audio output 

LINEOUTR 

AO 

Right channel audio output 

 

Type: AI=Audio Input, AG=Audio Ground (centrally connected to DGND), AO=Audio Output

 

 

Connector pin out 

J2 pin out (GPIO, UART, 
USB, I

2

C) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 
 
 
 
 
 
 
Connector pin out 

J3 pin out (USB OTG, Host) 

 

 

Pin # 

Name 

Type 

Description (usage) 

-RST 

Active low Reset I/O (Hardware reset from 
power surveillance) 

IO/IR-in/RXD3 

GPIO# PA14, Infrared input, UART_3 data 
receive, second amplifier shutdown 

DGND 

Digital Ground 

D0-REL 

GPIO#PA10 

IO/TXD3 

GPIO#PA13 / UART_3 data transmit 

IO/RTS3 

GPIO#PA15 / UART_3 flow control output 

IO/CTS3 

GPIO#PA16 / UART_3 flow control input 

OWA_OUT 

GPIO#PA17 / 

  

OWA(One Wire 

Audio);complies with SPDIF interface

 

Recovery 

VCC_IO_EN (Button for Reset/Factory 
defaults/Bootloader) 

10 

DGND 

Digital Ground 

11 

VIN 

Audio module input Voltage 3.3 VDC 

12 

CTS1 

UART_1 flow control input 

13 

RTS1 

UART_1 flow control output 

14 

RXD1 

UART_1 data receive  

15 

TXD1 

UART_1 data transmit  

16 

DGND 

Digital Ground 

17 

USBDM1 

USB 2.0 Host Interface negative 

18 

USBDP1 

USB 2.0 Host Interface positive 

19 

TWI0-SCK 

GPIO#PA11 /I²C Clock (Connected internally / 
Internal testing only) 

20 

TWI0-DA 

GPIO#PA12 /I²C Data (Connected internally / 
Internal testing only) 

 

Type: O=Output, I=Input, P=Power, B=bidirectional, D = Open Drain (pull-up resistor on 
module) 

 

Содержание IPAM 400

Страница 1: ...lus Wi Fi adding IP based streaming and controlling capabilities to OEM products Document version 02 20 Release date 9th April 2018 Hardware Rev HW 12 2017 Barix AG all rights reserved All information is subject to change without notice All mentioned trademarks belong to their respective owners and are used for reference only ...

Страница 2: ...P Yocto layer 5 HARDWARE 6 Mechanical drawing 6 Block diagram 7 Network interfaces 7 Serial interfaces 7 Digital audio 7 Analog audio 8 Power supply 8 Peripheral I O 8 CONNECTORS 9 Connector placement 9 Connector pin out 9 J1 pin out analog audio input and output 9 J2 pin out GPIO UART USB I2 C 9 J4 pin out network USB 10 J5 pin out I2 S output 10 LAYOUT GUIDELINES 11 General rules 11 Carrier PCB ...

Страница 3: ...o Processor Codec Decoding features 13 Line Input and A D Conversion typical values 14 Microphone input and A D conversion typical values 14 Line output and D A conversion typical values 14 Mechanical 14 Dimensions 14 Weight 14 MTBF calculations 15 Environmental 15 Core frequency versus Temperature variation 15 Certifications Compliances 16 ORDERING INFORMATION 17 ...

Страница 4: ...IO MODULE 400 enables manufacturers of traditional audio devices to add network capabilities to their products as well as develop IP streaming devices Hardware features The Barix IP AUDIO MODULE 400 features Stereo line input and output 0dBuStereo Line in and outputs Microphone input coil powered or passive capacitive balanced or unbalanced I2S input and output 192k capable Integrated SoC with ARM...

Страница 5: ... featuring a dual root file system strategy and a recovery mechanism Definition for a base SW image Scripts to create and install SW images and SW updates All these functionalities are configurable and adaptable to the developer s needs Developers can use the BSP to generate the toolchain that enables the development of any application The BSP package is a starting point and can be easily extended...

Страница 6: ...e the carrier board can be achieved when mounted on a carrier board by means of soldering the pin headers into holes of the carrier board directly Using single row female headers counterpart to pin headers the height will increase and must be measured by the integrator our experience in production shows a minimal height of 11 5mm above the carrier board without using distance bolts and 12mm using ...

Страница 7: ...SB 2 0 OTG and 2 x USB 2 0 Host The serial port UART0 can be used to build serial standard interfaces like RS 232 or RS 485 by attaching external driver chips Flow control signals are available for that UART The second UART shares its function with IO pins and is Tx Rx only One USB 2 0 On the Go and 2 x USB 2 0 Host interfaces supporting High Speed HS 480Mbps Full Speed FS 12Mbps and Low Speed LS ...

Страница 8: ...h pins is provided to power the Barix IP Audio Module from a single 3 3 Volt DC power source Several ground pins are implemented It is common practice to connect them all to the ground plate A separate ground domain for the analog part needs to be connected via separate ground pin Max power consumption of the IPAM 400 is 4 Watts A separate ground is provided for the audio interfaces Peripheral I O...

Страница 9: ...w Reset I O Hardware reset from power surveillance 2 IO IR in RXD3 B GPIO PA14 Infrared input UART_3 data receive second amplifier shutdown 3 DGND P Digital Ground 4 D0 REL B GPIO PA10 5 IO TXD3 B GPIO PA13 UART_3 data transmit 6 IO RTS3 B GPIO PA15 UART_3 flow control output 7 IO CTS3 B GPIO PA16 UART_3 flow control input 8 OWA_OUT B GPIO PA17 OWA One Wire Audio complies with SPDIF interface 9 Re...

Страница 10: ...sceiver negative output 4 DGND P Digital Ground 5 EPHY RXN I Transceiver negative input 6 RCT R Receive Transformer center Tap 7 EPHY RXP I Transceiver positive input 8 DGND P Digital Ground 9 USBDM2 B USB 2 0 Host Interface negative 10 EPHY SPD LED O Ethernet 10 100M indicator LED 11 EPHY LINK LED O Ethernet LINK up down LED 12 USBDP2 B USB 2 0 Host Interface positive Type O Output I Input P Powe...

Страница 11: ...istors to DGND The exact value of the terminations may need to be checked or confirmed by a designer and are in the vicinity of 15 Kilo Ohms 5 These termination resistors should be close to either the USB socket or the IPAM connector A more complex capacitive termination may be needed under some circumstances Any unused pins can be left open to save power consumption no pull up or pull down needed...

Страница 12: ... input voltage to 3 3 volts using zener diodes ZDi right after the resistor Carrier PCB Power and Signal Domains Relevant excerpt from previous chapter General Rules All available ground pins of the Barix Audio Module should be attached to their respective ground domain You MUST provide analog ground to the PCB and that ground must be connected to the power supply ground externally to the IPAM on ...

Страница 13: ...lity 10 100 Mbit full half duplex auto negotiation Status display Link Activity LED Protocols TCP IP UDP RTP SIP DHCP Serial interfaces Parameter COM 1 UART 0 Signals RxD CTS both TTL 3 3 VDC TxD RTS both TTL 3 3VDC VH min 0 7 Vin GND Baud rates 300 115200 Data bits 7 or 8 Parity No Even Odd Stop bits 1 or 2 Flow control No XON XOFF Peripheral I O interfaces Parameter Min Max Unit IIN Out current ...

Страница 14: ...line input signal to noise ratio SNR 73 dB Dynamic Range 16 bit theoretical 96 dB Input Total Harmonic Distortion THD 3dBFS 0 018 Software selectable input gain on microphone input Audio interfaces Line output and D A conversion typical values Parameter Value Unit Full Scale Output Voltage Peak to peak unloaded 2 39 0 844 0 745 VPP VRMS dBu Analog output impedance tbd Ω Frequency response 3dB 48 k...

Страница 15: ...Parameter Value Unit Operating Temperature Range 20 65 4 149 C F Operating Humidity Range non condensing 0 70 Storage Temperature Range 0 70 32 158 C F Storage Humidity Range non condensing 0 70 Core frequency versus Temperature variation CPU load 100 Core frequency versus Temperature variation CPU load 50 100 300 500 700 900 1100 1300 40 30 20 10 0 5 10 15 20 25 30 35 40 45 50 55 60 65 Core 1 fre...

Страница 16: ...h the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following m...

Страница 17: ...eference only Barix and Barix IP Audio Module are trademarks of Barix AG Switzerland and are registered in certain countries Newest information about our devices is available via download from our website www barix com We explicitly reserve the right to change and improve the product without notice Barix AG Ringstrasse 15a 8600 Dübendorf SWITZERLAND T 41 43 433 22 11 F 41 44 274 28 49 www barix co...

Отзывы: