Exstreamer User Manual Version 1.7
10.2 Network configuration using telnet
STEP 1
Unplug the power supply of the Exstreamer.
STEP 2
Keep the Reset button pushed and plug in the power
supply. Release the Reset button after 5 seconds.
STEP 3
Run a command session. Type telnet in the run window
with the IP address announced by Sonic IP on port 9999.
Example: telnet 192.168.0.12 9999
You will see the following screen:
Hit <enter> to access the Exstreamer in the setup mode.
STEP 9
Type in <0> and hit <enter> to enter the Network
configuration. Enter all requested values.
STEP 10
Type in <9> and hit <enter> to save the Network
configuration.
10.3 Control APIs for serial and
Ethernet
For integration of the Exstreamer into various control
applications and home automation systems, Barix has
developed a control API (Application Protocol Interface)
for the serial port and Ethernet UDP and TCP control.
Serial Port control API
The serial port on the Exstreamer can be used to send
control commands from a home automation system and
other PC or embedded applications. In the device
configuration the serial port can be adjusted to suit your
application.
For a detailed list of serial commands refer to the
Exstreamer Digital Technical Documentation available on
the Barix website www.barix.com
Ethernet UDP or TCP control commands
The same control commands used on the serial port can be
used as UDP or TCP commands over Ethernet.
For more information and a detailed list of UDP and TCP
control commands refer to the Exstreamer Digital
Technical Documentation available on the Barix website
www.barix.com