background image

Front view

A  Reset button

A brief press of the button will reset the device.
Holding the reset button pressed in for approximately 
10 seconds will reset the device and restore the factory 
default settings when the button is released.

B EXT.

USB interface solely for flash memory sticks (not supplied)

C  Green and red LEDs

for device status display

D  Green LEDs 

(1...4)

I/O status display 

E  I/O 1&2 

(6 pin screw terminal block plug)

Pin Description

1  

Output Relay 1

Common Relay 1&2

3  

Output Relay 2

4  

Input 1

5  

Ground (-) Input 1&2

6  

Input 2

F  I/O 3&4 

(6 pin screw terminal block plug)

Pin Description

1  

Output Relay 3

2  

Common Relay 3&4

3  

Output Relay 4

4  

Input 3

5  

Ground (-) Input 3&4

6  

Input 4

K  RS-485 bus 

(4 pin screw terminal block plug)

Pin Description

1  

485 B

2  

Reference *

3  

485 A

4  

Shield

*The reference pinis connected via 100 Ohm to the internal 
ground.

Rear view

G  Analog audio In & Out 

(DSub 9 pin female)

Pin Description

1  

Left Out+ [Hot]

2  

Left Out- [Cold]

3  

Ground [G]

4  

Right In+ [Hot]

5  

Right In- [Cold]

6  

Right Out+ [Hot]

7  

Right Out- [Cold]

8  

Left In+ [Hot]

9  

Left In- [Cold]

H  RS-232 serial port 

(DSub 9 pin male)

Pin Description

1,6,9  

Not connected

2  

Receive Data [RxD]

3  

Transmit Data [TxD]

4  

V+ 14.6V, 100mA max

5  

Ground [GND]

7  

Ready to Send [RTS]

8  

Clear to Send [CTS]

LAN port 10/100 

(RJ45 Ethernet socket)

Pin Description

1  

Tx +

2  

Tx -

3  

Rx +

4,5,7,8   Not connected

6  

Rx -

 

LAN status LEDs 

Green LED for Link, yellow LED for Activity  

 
L Power 

(8 Watt max.)

Pin Description

1  

Vin -

2  

Vin+ 24..48VDC ±20%

D

B

A

C

F

H

G

I

E

K L

J

Содержание Exstreamer 500

Страница 1: ...es preloaded with standard firmware Alternative firmware can be downloaded from www barix com Support For support please contact your local dealer or visit www barix com Barix AG 3 2013 all rights reserved All information is subject to change without notice All mentioned trademarks belong to their respective owners and are used for reference only Barix Exstreamer and SonicIP are trademarks of Bari...

Страница 2: ...elay 4 4 Input 3 5 Ground Input 3 4 6 Input 4 K RS 485 bus 4 pin screw terminal block plug Pin Description 1 485 B 2 Reference 3 485 A 4 Shield The reference pinis connected via 100 Ohm to the internal ground Rear view G Analog audio In Out DSub 9 pin female Pin Description 1 Left Out Hot 2 Left Out Cold 3 Ground G 4 Right In Hot 5 Right In Cold 6 Right Out Hot 7 Right Out Cold 8 Left In Hot 9 Lef...

Страница 3: ...net MAC address matches your device see label on the bottom of the device Now that you know the IP address proceed to section 2 Network configuration by web browser If you were not able to obtain the device s current IP address with the previous steps see section Troubleshooting 2 Network configuration by web browser Most Barix applictaions require no configuration but use DHCP to configure networ...

Страница 4: ...ve administrative rights to be able to do so sudo on OSX Linux STEP 5 Now we have to make the Exstreamer listen to the IP address 192 168 0 6 using the Telnet command To do so type into the command window telnet 192 168 0 6 1 and hit the Enter key the number one must be there for this command to work correctly The Exstreamer will immediately refuse the connection on port 1 but will be available fo...

Отзывы: