![BARIX Annuncicom 1000 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/barix/annuncicom-1000/annuncicom-1000_quick-install-manual_475050003.webp)
Network configuration by web browser
STEP 1
Open your web browser.
STEP 2
Enter the IP address of the Annuncicom 1000 and press
Enter.
Example: 192.168.0.12
STEP 3
Click on the Configuration button.
STEP 4
Enter an IP address into the 4 IP address fields. At default it
is 0.0.0.0 for automatic discovery. Ask your network admin
before using the IP address announced by SonicIP.
STEP 5
In normal operating conditions leave the Netmask as is.
STEP 6
The Gateway, primary and alternative DNS IP addresses as
well as Sonic IP can be left at default for now.
STEP 7
Hit the Apply button to save all changes.
The Annuncicom 1000 will reboot with a Static IP address.
Please continue with section “Next steps” on last page.
Network configuration using supplied
serial cable
STEP 1
Open a Terminal program.
STEP 2
Go to the settings menu of the terminal program and
adjust the following settings:
Baud rate 9600 bit/sec, 8 Data Bits, no Parity, 1 Stop Bit
STEP 3
Unplug the power supply of the Annuncicom 1000.
STEP 4
Connect the supplied serial cable to your PC’s COM port
and to the serial port of the Annuncicom.
STEP 5
Keep the Reset button pushed and plug in the power
supply. Release the Reset button as soon as you see the
following screen:
STEP 6
Hit <s> to skip network discovery if not connected to a
network and the following screen appears:
STEP 7
Hit <s> to get to the Annuncicom setup.
STEP 8
Hit <enter> to enter the Annuncicom setup mode.