background image

4. 

Check if all Portafilters fit properly and 

tighten screws firmly.

4. 

Remove tamper base by turning from left 

to right.

2. 

Release lower clamp bolts.

Set up the lower clamp

Once

every

week

Maintenance

3. 

Insert the portafilter in-between the 

upper- and lower clamp.
Turn the adjustment wheel clockwise to move the 

lower clamp up against the Portafilter.

!

!

!

CLEAN

PRESSURE

CLEAN

PRESSURE

CLEAN

PRESSURE

PRESSURE

PRESSURE

PRESSURE

PRESSURE

CLEAN

PRESSURE

WARNING:

Failure to adjust the lower clamp to 

optimum working position may 

allow contact with moving parts. 

Portafilter should not wiggle

!

Improper lower clamp setting may 

also cause damage to drive mecha-

nism. 

For instruction video check 

www.puqpress.com/support

1. 

Press “Cleaning”.

2. 

Turn the Mythos 90 degrees and get the Allen key.

3. 

Unscrew by turning counter-clockwise and remove 

the bolt.

5. 

Clean cavity with a brush.

1. 

Remove the power cable.

5. 

Test if the Portafilter fits well. 

It should not wiggle.

Use this funtions only 

after contact with your 

local dealer.

Use this funtions only after contact 

with your local dealer.

Cycle counter cannot be reset using 

this function.

Tamping cycle time 

increases with 0.8 s.

1. 

Switch off the power. 

Press and Hold the 

‘CLEAN’ 

and 

‘+’ 

button while the power is 

switched back on. 

“SE”

 flashes in the display.

In 

standby mode

, press and hold 

‘+’

 and 

‘-’ 

button for 

3 sec.

The display will flash a number for 5 sec. 
Multiply this number by 5.000 to get cycle 

count.

2.

Press 

‘CLEAN’

 

button to step 
through menu 
(B to F).

A. Activate menu 

NEW TAMP SETTINGS

I. Tamping cycle count

1. 

Press the 

‘CLEAN’

 button to bring tamper in 

cleaning position. Now press and hold 

‘+’

 and 

‘-’ 

button for 

3 sec. 

Multiply this number by 20 to get cycle count. 

II. Cleaning cycle count

B. Not in use

C. Change tamp weight 
setting 

(KG or LBS)

D. Slow tamp 
mode

E. Firmware version

1. 

Activate menu and press 

‘CLEAN’

 1 time so that 

‘C0’

 is 

shown (see step A).

1. 

Activate menu and press 

‘CLEAN’

 2 times so that 

‘C1’

 is 

shown (see step A).

1. 

Activate menu and press 

‘CLEAN’

 3 times so that 

‘C2’

 

is shown (see step A).

1. 

Activate menu and press 

‘CLEAN’

 4 times so that 

‘Fr’

 

is shown (see step A).

2. 

Press

 ‘+’

 or 

‘-’ 

to see 

the revision number.

2. 

Press

 ‘+’ and ‘-’ 

for 1 sec. to 

reset the device back to default 

settings.

F. Reset factory default

2. 

Use’+’ and ‘-’ to change setting.

00

 = NORMAL TAMPING

01

 = SLOW TAMPING

2. 

Use 

’+’

 and 

‘-’

 to change 

setting.

00

 = KG

01

 = LBS

3. 

To finish selection, press

 

‘CLEAN’

 button 4 times to exit 

menu.

3. 

To finish selection, press

 

‘CLEAN’

 3 times to exit menu.

3. 

Press 

‘CLEAN’

 2 times 

to exit menu.

3. 

Press 

‘CLEAN’

  to exit 

menu.

2. 

‘SE’ not in use. Go to 

setting C0 by pressing 

‘CLEAN’

 button.

Problems 
with your 

puck falling 

out? Use this 

setting!

Отзывы: