Getting Other Information and Publications

These publications can help you install the air conditioner
or heat pump.  You can usually find these at your local
library or purchase them directly from the publisher.  Be
sure to consult current edition of each standard.

National Electrical Code ........................ ANSI/NFPA 70

Standard for the Installation ................... ANSI/NFPA 90A
of Air Conditioning and Ventilating Systems

Standard for Warm Air .......................... ANSI/NFPA 90B
Heating and Air Conditioning Systems

Load Calculation for .............................. ACCA Manual J
Residential Winter and Summer Air Conditioning

Duct Design for Residential ................... ACCA Manual
D Winter and Summer Air Conditioning and Equipment
Selection

For more information, contact these
publishers:

ACCA

Air Conditioning Contractors of America

1712 New Hampshire Ave. N.W.
Washington, DC 20009
Telephone: (202) 483-9370
Fax: (202) 234-4721

ANSI

American National Standards Institute

11 West Street, 13th Floor
New York, NY 10036
Telephone: (212) 642-4900
Fax: (212) 302-1286

ASHRAE American Society of Heating Refrigerating,

and Air Conditioning Engineers, Inc.

1791 Tullie Circle, N.E.
Atlanta, GA 30329-2305
Telephone: (404) 636-8400
Fax: (404) 321-5478

NFPA

National Fire Protection Association

Batterymarch Park
P.O. Box 9101
Quincy, MA 02269-9901
Telephone: (800) 344-3555
Fax: (617) 984-7057

Содержание WL7013B

Страница 1: ...NTED PACKAGE AIR CONDITIONERS Model WL7013B WL7023A INSTALLATION INSTRUCTIONS Manual 2100 428A Supersedes 2100 428 File Volume III Tab 16 Date 07 25 06 Bard Manufacturing Company Inc Bryan Ohio 43506 Since 1914 Moving ahead just as planned ...

Страница 2: ...CFM and Rated ESP 17 Table 9 Maximum ESP of Operation Electric Heat Only 17 Table 10 Pressure Table 18 Getting Other Information and Publications 3 Wall Mount General Information Air Conditioning Wall Mount Model Nomenclature 4 Shipping Damage 6 General 6 Duct Work 6 7 Condensate Drain 7 Installation Instructions Wall Mounting Information 8 Mounting the Unit 8 Wiring Main Power 13 Wiring Low Volta...

Страница 3: ...nter and Summer Air Conditioning Duct Design for Residential ACCA Manual D Winter and Summer Air Conditioning and Equipment Selection For more information contact these publishers ACCA Air Conditioning Contractors of America 1712 New Hampshire Ave N W Washington DC 20009 Telephone 202 483 9370 Fax 202 234 4721 ANSI American National Standards Institute 11 West Street 13th Floor New York NY 10036 T...

Страница 4: ...H U T B 0 9 7 1 2 0 0 6 0 3 7 8 1 0 3 0 3 2 0 0 1 6 1 4 0 3 1 4 3 2 6 3 0 0 6 5 2 MODEL NUMBER CONTROL MODULES CAPACITY 70 6 Ton VOLTS PHASE A 230 208 60 1 B 230 208 60 3 REVISIONS KW VENTILATION OPTIONS B Blank off Plate FILTER OPTIONS N No Filter COLOR OPTIONS X Beige Standard 1 White 2 Mesa Tan 4 Buckeye Gray COIL OPTIONS X Standard 1 Phenolic Coated Evaporator 2 Phenolic Coated Condenser 3 Phe...

Страница 5: ...Manual 2100 428A Page 5 of 18 FIGURE 1 UNIT DIMENSIONS ...

Страница 6: ...on to note 8 of table 310 regarding Ampacity Adjustment Factors when more than 3 conductors are in a raceway TABLE 2 ELECTRICALSPECIFICATIONS l e d o M T I U C R I C E L G N I S d e t a R s t l o V e s a h P o N d l e i F r e w o P s t i u c r i C 3 m u m i n i M t i u c r i C y t i c a p m A 1 m u m i x a M l a n r e t x E r o e s u F t k C r e k a e r B 2 d l e i F r e w o P e r i W e z i S 2 d ...

Страница 7: ... air duct A metallic return air grille is required with installations not requiring a return air duct The spacing between louvers on the grille shall not be larger than 5 8 inch NOTE If no return air duct is used applicable installation codes may limit this cabinet to installation only in a single story structure Any grille that meets with 5 8 inch louver criteria may be used It is recommended tha...

Страница 8: ...ply air opening would then be 32 x 12 See Figures 2 and 3 for details WARNING Failure to provide the 1 4 inch clearance between the supply duct and a combustible surface for the first 3 feet of duct can result in fire causing damage injury or death 3 Locate and mark lag bolt locations and bottom mounting bracket location See Figure 2 4 Mount bottom mounting bracket 5 Hook top rain flashing under b...

Страница 9: ...Manual 2100 428A Page 9 of 18 FIGURE 2 MOUNTING INSTRUCTIONS ...

Страница 10: ...s This is required for the first 3 feet of ducting It is important to insure that the 1 4 inch minimum spacing is maintained at all points Failure to do this could result in overheating the combustible material and may result in a fire causing damage injury or death SIDE SECTION VIEW OF SUPPLY AIR DUCT FOR WALL MOUNTED UNIT SHOWING 1 4 INCH CLEARANCE TO COMBUSTIBLE SURFACES ...

Страница 11: ...Manual 2100 428A Page 11 of 18 SEE UNIT DIMENSIONS FIGURE 1 FOR ACTUAL DIMENSIONS FIGURE 4 WALL MOUNTING INSTRUCTIONS FIGURE 5 WALL MOUNTING INSTRUCTIONS ...

Страница 12: ...Manual 2100 428A Page 12 of 18 FIGURE 6 COMMON WALL MOUNTING INSTALLATIONS ...

Страница 13: ...pening under the disconnect access panel straight out This tab will now line up with the slot in the door When shut a padlock may be placed through the hole in the tab preventing entry See Start Up section for important information on three phase scroll compressor start ups WIRING LOW VOLTAGE WIRING 230 208V 1 phase and 3 phase equipment dual primary voltage transformers All equipment leaves the f...

Страница 14: ...Manual 2100 428A Page 14 of 18 FIGURE 7 UNIT 24V TERMINAL BOARD ...

Страница 15: ... or installation connecting properly phased power leads to the same Fusite terminal should maintain proper rotation direction The direction of rotation of the compressor may be changed by reversing any two line connections to the unit SERVICE HINTS 1 Caution homeowner to maintain clean air filters at all times Also not to needlessly close off supply and return air registers This reduces airflow th...

Страница 16: ...ut features both soft and manual are a function of the Compressor Control Module ADJUSTMENTS Adjustable Delay on Make and Delay on Break Timer The potentiometer is used to select Delay on Break time from 30 seconds to 5 minutes Delay on Make DOM timing on power up and after power interruptions is equal to 2 minutes plus 10 of Delay on Break DOB setting 0 5 minute 30 seconds DOB 123 second DOM 1 0 ...

Страница 17: ...L W 5 2 1 TABLE 6 INDOOR BLOWER PERFORMANCE CFM 230V P S E H n I 2 O 0 7 L W d e e p S h g i H l i o C y r D l i o C t e W 0 1 2 5 7 7 1 5 7 6 1 5 7 5 1 0 0 6 1 5 2 5 1 5 2 4 1 TABLE 8 RATED CFM AND ESP l e d o M d e t a R M F C d e t a R P S E d e d n e m m o c e R e g n a R w o l f r i A 0 7 L W 5 2 4 1 0 2 0 5 2 4 1 5 7 7 1 1 TABLE 9 MAXIMUM ESP OF OPERATION ELECTRIC HEAT ONLY Values shown are ...

Страница 18: ...2 1 7 2 7 2 2 7 9 8 2 3 7 5 0 3 4 7 4 2 3 5 7 3 4 3 B D g e d 0 8 B W g e d 7 6 e d i S w o L e d i S h g i H 3 7 0 2 2 3 7 4 3 2 4 7 8 4 2 5 7 3 6 2 6 7 9 7 2 7 7 6 9 2 8 7 3 1 3 9 7 2 3 3 0 8 2 5 3 B D g e d 5 8 B W g e d 2 7 e d i S w o L e d i S h g i H 6 7 8 2 2 6 7 2 4 2 7 7 7 5 2 8 7 2 7 2 9 7 9 8 2 0 8 6 0 3 1 8 4 2 3 2 8 4 4 3 3 8 4 6 3 B 3 1 0 7 L W B D g e d 5 7 B W g e d 2 6 e d i S w ...

Отзывы: