Manual 2100-401A
Page

3 of 21

Getting Other Information and Publications

These publications can help you install the air
conditioner or heat pump.  You can usually find these at
your local library or purchase them directly from the
publisher.  Be sure to consult current edition of each
standard.

National Electrical Code ....................... ANSI/NFPA 70

Standard for the Installation ............... ANSI/NFPA 90A
of Air Conditioning and Ventilating Systems

Standard for Warm Air ........................ ANSI/NFPA 90B
Heating and Air Conditioning Systems

Load Calculation for ............................. ACCA Manual J
Residential Winter and Summer Air Conditioning

Duct Design for Residential ............... ACCA Manual  D
Winter and Summer Air Conditioning and Equipment
Selection

For more information, contact these
publishers:

ACCA

Air Conditioning Contractors of America

1712 New Hampshire Ave. N.W.
Washington, DC 20009
Telephone: (202) 483-9370
Fax: (202) 234-4721

ANSI

American National Standards Institute

11 West Street, 13th Floor
New York, NY 10036
Telephone: (212) 642-4900
Fax: (212) 302-1286

ASHRAE American Society of Heating, Refrigerating,

and Air Conditioning Engineers, Inc.

1791 Tullie Circle, N.E.
Atlanta, GA 30329-2305
Telephone: (404) 636-8400
Fax: (404) 321-5478

NFPA

National Fire Protection Association

Batterymarch Park
P.O. Box 9101
Quincy, MA 02269-9901
Telephone: (800) 344-3555
Fax: (617) 984-7057

Содержание WA4842

Страница 1: ...STRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS WA4842 WA4843 WA6022 WA6023 Manual 2100 401A Supersedes 2100 401 File Volume III Tab 16 Date 07 25 06 Bard Manufacturing Company Inc Bryan Ohio...

Страница 2: ...arge 19 Table 8 Rated CFM and Rated ESP 19 Table 9 Maximum ESP of Operation Electric Heat Only 20 Table 10 Pressure Table 20 Table 11 Optional Accessories 21 Getting Other Information and Publications...

Страница 3: ...ter and Summer Air Conditioning Duct Design for Residential ACCA Manual D Winter and Summer Air Conditioning and Equipment Selection For more information contact these publishers ACCA Air Conditioning...

Страница 4: ...0 5 0 7 1 1 8 1 0 0 8 2 1 0 9 7 1 2 0 0 6 0 3 7 8 1 0 3 0 3 2 0 0 1 6 1 4 0 3 1 4 3 2 6 3 0 0 6 5 2 MODEL NUMBER CONTROL MODULES CAPACITY 60 5 Ton VOLTS PHASE A 230 208 60 1 B 230 208 60 3 REVISIONS K...

Страница 5: ...Manual 2100 401A Page 5 of 21 FIGURE 1 UNIT DIMENSIONS WA6023 WA4843 ONLY...

Страница 6: ...Manual 2100 401A Page 6 of 21 FIGURE 2 UNIT DIMENSIONS WA6022 WA4842 ONLY...

Страница 7: ...i c a p m A 1 m u m i x a M e s u F l a n r e t x E r o r e k a e r B t k C 2 r e w o P d l e i F e z i S e r i W 2 d n u o r G e z i S e r i W A T K C B T K C A T K C B T K C A T K C B T K C A T K C...

Страница 8: ...ags and or labels attached to the equipment Design the duct work according to methods given by the Air Conditioning Contractors of America ACCA When duct runs through unheated spaces it should be insu...

Страница 9: ...et of supply air duct require a minimum of 1 4 inch clearance to combustible material If a combustible wall use a minimum of 30 x 10 dimensions for sizing However it is generally recommended that a 1...

Страница 10: ...Manual 2100 401A Page 10 of 21 FIGURE 3 MOUNTING INSTRUCTIONS WA6023 WA4843 ONLY...

Страница 11: ...Manual 2100 401A Page 11 of 21 FIGURE 4 MOUNTING INSTRUCTIONS WA6022 WA4842 ONLY...

Страница 12: ...This is required for the first 3 feet of ducting It is important to insure that the 1 4 inch minimum spacing is maintained at all points Failure to do this could result in overheating the combustible...

Страница 13: ...Manual 2100 401A Page 13 of 21 FIGURE 6 WALL MOUNTING INSTRUCTIONS FIGURE 7 WALL MOUNTING INSTRUCTIONS SEE FIGURE 3 MOUNTING INSTRUCTIONS SEE UNIT DIMENSIONS FIGURE 1 FOR ACTUAL DIMENSIONS...

Страница 14: ...Manual 2100 401A Page 14 of 21 FIGURE 8 COMMON WALL MOUNTING INSTALLATIONS...

Страница 15: ...ening under the disconnect access panel straight out This tab will now line up with the slot in the door When shut a padlock may be placed through the hole in the tab preventing entry See Start Up sec...

Страница 16: ...Manual 2100 401A Page 16 of 21 FIGURE 9 UNIT 24V TERMINAL BOARD...

Страница 17: ...etermined for a specific system or installation connecting properly phased power leads to the same Fusite terminal should maintain proper rotation direction The direction of rotation of the compressor...

Страница 18: ...ual covering all models It is imperative to match the correct pressure table to the unit by model number Adjustable Delay On Make And Break Timer On initial power up or any time power is interrupted t...

Страница 19: ...e e p S h g i H d e e p S h g i H d e e p S h g i H y r D l i o C t e W l i o C y r D l i o C t e W l i o C y r D l i o C t e W l i o C y r D l i o C t e W l i o C 0 1 2 5 7 7 1 5 7 6 1 5 7 5 1 0 0 6...

Страница 20: ...1 0 1 1 5 1 1 2 0 6 A W B D g e d 5 7 B W g e d 2 6 e d i S w o L e d i S h g i H 1 7 3 3 2 2 7 7 4 2 4 7 2 6 2 5 7 8 7 2 6 7 5 9 2 7 7 3 1 3 8 7 1 3 3 8 7 1 5 3 9 7 1 7 3 B D g e d 0 8 B W g e d 7 6...

Страница 21: ...A WA4842A WA4843B WA4842B t r a P r e b m u N n o i t p i r c s e D 5 1 C M C t i K t r a t S X X A 9 0 B C M W B 7 0 B C M W A 8 0 B C M W B 5 0 B C M W t i K r e k a e r B t i u c r i C t i K r e k...

Отзывы: