Manual 2100-511
Page

4 of 27

WALL MOUNT GENERAL INFORMATION

HEAT PUMP WALL MOUNT MODEL NOMENCLATURE

W

42

H

1

A

10

X

X

X

X

X

A

NOTE:  Vent options X, B and M are without exhaust capability.  May require separate field supplied barometric relief in building.

SHIPPING DAMAGE

Upon receipt of equipment, the carton should be
checked for external signs of shipping damage.  If
damage is found, the receiving party must contact the
last carrier immediately, preferably in writing,
requesting inspection by the carrier’s agent.

GENERAL

The equipment covered in this manual is to be installed
by trained, experienced service and installation
technicians.

The refrigerant system is completely assembled and
charged.  All internal wiring is complete.

The unit is designed for use with or without duct work.
Flanges are provided for attaching the supply and return
ducts.

These instructions explain the recommended method to
install the air cooled self-contained unit and the
electrical wiring connections to the unit.

These instructions and any instructions packaged with
any separate equipment required to make up the entire
air conditioning system should be carefully read before
beginning the installation.  Note particularly “Starting
Procedure” and any tags and/or labels attached to the
equipment.

While these instructions are intended as a general
recommended guide, they do not supersede any national
and/or local codes in any way.  Authorities having
jurisdiction should be consulted before the installation is
made.  See Page 3 for information on codes and
standards.

Size of unit for a proposed installation should be based
on heat loss/gain calculation made according to methods
of Air Conditioning Contractors of America (ACCA).
The air duct should be installed in accordance with the
Standards of the National Fire Protection Association
for the Installation of Air Conditioning and Ventilating
Systems of Other Than Residence Type, NFPA No.
90A, and Residence Type Warm Air Heating and Air
Conditioning Systems, NFPA No. 90B.  Where local
regulations are at a variance with instructions, installer
should adhere to local codes.

KW

MODEL NUMBER

CONTROL MODULES

(See Spec. Sheet S3397)

VOLTS & PHASE

A - 230/208/60/1
B - 230/208/60/3
C - 460/60/3

REVISIONS

VENTILATION OPTIONS

X - Barometric Fresh Air Damper (Standard)
B - Blank-off Plate
M - Motorized Fresh Air Damper
V - Commercial Ventilator - Motorized with Exhaust
E - Economizer (Internal) - Fully Modulating with Exhaust
R - Energy Recovery Ventilator - Motorized with Exhaust

(See Spec. Sheet S3398)

FILTER OPTIONS

X - One Inch Throwaway (Standard)
W - One Inch Washable
P - Two Inch Pleated

COLOR OPTIONS

X - Beige (Standard)
1 - White
2 - Mesa Tan
4 - Buckeye Gray
5 - Desert Brown
8 - Dark Bronze

COIL OPTIONS

X - Standard
1 - Phenolic Coated Evaporator
2 - Phenolic Coated Condenser
3 - Phenolic Coated Evaporator

and Condenser

OUTLET OPTIONS

X - Front (Standard)
T - Top Outlet (W30H, W36H Only)

CAPACITY

18 - 1½ Ton
24 - 2 Ton
30 - 2½ Ton
36 - 3 Ton
42 - 3½ Ton
48 - 4 Ton
60 - 5 Ton

H - Heat Pump

Содержание W18H1

Страница 1: ...S WALL MOUNTED PACKAGE HEAT PUMPS MODELS W18H1 W24H1 W30H1 W36H1 W42H1 W48H1 W60H1 Manual 2100 511 Supersedes NEW File Volume III Tab 17 Date 10 14 08 Bard Manufacturing Company Inc Bryan Ohio 43506 S...

Страница 2: ...Maximum ESP Electric Heat Only 25 Table 9 Electric Heat 25 Table 10 Optional Accessories 26 Table 11 Vent Control Options 27 Getting Other Information and Publications 3 Wall Mount General Information...

Страница 3: ...ial ACCA Manual D Winter and Summer Air Conditioning and Equipment Selection FOR MORE INFORMATION CONTACT THESE PUBLISHERS ACCA Air Conditioning Contractors of America 1712 New Hampshire Ave N W Washi...

Страница 4: ...ny national and or local codes in any way Authorities having jurisdiction should be consulted before the installation is made See Page 3 for information on codes and standards Size of unit for a propo...

Страница 5: ...RG2 through RG5 or RFG2 through RFG5 be installed when no return duct is used Contact distributor or factory for ordering information If using a return air filter grille filters must be of sufficient...

Страница 6: ...sides A bottom mounting bracket attached to skid for shipping is provided for ease of installation but is not required 2 The unit itself is suitable for 0 inch clearance but the supply air duct flange...

Страница 7: ...6 0 2 2 5 5 0 1 0 0 5 0 0 2 1 0 0 5 1 H 0 3 W 1 H 6 3 W 0 0 2 8 3 5 2 1 7 1 3 6 5 0 7 8 8 7 8 8 7 2 8 8 3 1 8 8 7 2 0 0 0 4 0 5 8 1 5 7 5 2 3 9 7 1 5 7 6 2 5 7 8 2 5 2 9 2 0 0 7 2 3 6 2 3 1 9 3 5 7 2...

Страница 8: ...Manual 2100 511 Page 8 of 27 FIGURE 3A W18H1 W24H1 MOUNTING INSTRUCTIONS...

Страница 9: ...Manual 2100 511 Page 9 of 27 FIGURE 3B W30H1 W36H1 MOUNTING INSTRUCTIONS...

Страница 10: ...Manual 2100 511 Page 10 of 27 FIGURE 3C W42H1 W48H1 W60H1 MOUNTING INSTRUCTIONS...

Страница 11: ...tible materials This is required for the first 3 feet of ducting It is important to insure that the 1 4 inch minimum spacing is maintained at all points Failure to do this could result in overheating...

Страница 12: ...2100 511 Page 12 of 27 FIGURE 5 WALL MOUNTING INSTRUCTIONS FIGURE 6 WALL MOUNTING INSTRUCTIONS SEE FIGURE 3 MOUNTING INSTRUCTIONS SEE UNIT DIMENSIONS FIGURE 2 FOR ACTUAL DIMENSIONS IF REQUIRED IF REQ...

Страница 13: ...Manual 2100 511 Page 13 of 27 FIGURE 7 COMMON WALL MOUNTING INSTALLATIONS...

Страница 14: ...circuit breaker that is to be used with the equipment The correct size must be used for proper circuit protection and also to assure that there will be no nuisance tripping due to the momentary high...

Страница 15: ...iple leaks and recharges R 410A refrigerant is close to being an azeotropic blend it behaves like a pure compound or single component refrigerant The remaining refrigerant charge in the system may be...

Страница 16: ...eral minutes the compressor s internal protector will trip All three phase ZP compressors are wired identically internally As a result once the correct phasing is determined for a specific system or i...

Страница 17: ...ol which will return the system to heating operations automatically If some abnormal or temporary condition such as a high wind causes the heat pump to have a prolonged defrost cycle the heat pump con...

Страница 18: ...Manual 2100 511 Page 18 of 27 FIGURE 8 DEFROST CONTROL BOARD...

Страница 19: ...i h e h t f I t i u c r i c d e s o l c a s i o t n o d n a f f o r e w o p e l c y C t n e n o p m o c e v i t c e f e d e c a l p e R r o s s e r p m o c e h t t u o k c o l l l i w l o r t n o c y...

Страница 20: ...4 0 7 4 0 8 4 0 9 4 0 0 5 5 8 9 6 5 4 8 2 5 5 0 4 6 3 5 1 5 0 2 5 4 1 5 0 5 8 2 0 9 4 0 9 5 7 4 0 0 2 6 4 5 5 8 4 4 4 5 5 3 4 5 9 2 2 4 7 7 0 1 4 8 9 8 9 3 7 5 7 8 3 2 5 6 7 3 3 8 5 6 3 8 4 5 5 3 5 4...

Страница 21: ...The suction line temperatures in Table 3 above are based upon 80 F dry bulb 67 F wet bulb 50 R H temperature and rated airflow across the evaporator during cooling cycle TABLE 3 REFRIGERANTCHARGE l e...

Страница 22: ...B W g e d 2 6 e d i S w o L e d i S h g i H 7 2 1 4 5 3 0 3 1 2 7 3 2 3 1 2 9 3 4 3 1 3 1 4 5 3 1 7 3 4 6 3 1 1 6 4 7 3 1 8 8 4 7 3 1 6 1 5 7 3 1 6 4 5 6 3 1 8 7 5 B D g e d 0 8 B W g e d 7 6 e d i S...

Страница 23: ...0 3 W 6 0 B 3 9 0 B 3 8 0 2 0 3 2 1 1 1 8 1 6 3 5 4 5 2 0 4 5 4 0 1 8 8 0 1 0 1 0 1 Z 0 C 0 0 C 1 H 0 3 W 6 0 C 3 9 0 C 5 1 C 3 0 6 4 1 1 1 1 1 1 0 2 5 2 6 2 5 1 0 2 5 2 0 3 4 1 2 1 0 1 0 1 4 1 2 1 0...

Страница 24: ...p S w o L y r D l i o C t e W l i o C y r D l i o C t e W l i o C y r D l i o C t e W l i o C y r D l i o C t e W l i o C y r D l i o C t e W l i o C y r D l i o C t e W l i o C y r D l i o C t e W l...

Страница 25: ...e p S w o L d e e p S h g i H d e e p S w o L 0 0 A 4 0 A 5 0 A 0 1 A 5 1 A 0 2 A 0 5 0 5 0 5 0 5 0 5 0 5 5 4 5 4 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 5 4 5 4 5 4 0 5 0 5 0 5 0 5 0 5 0 4 5 2 5 2 5 2 5...

Страница 26: ...X 6 0 B 3 0 H W H E X 6 0 B H 6 3 W H E X 9 0 B 3 0 H W H E X X 5 1 B H 0 3 W H E X 6 0 C A 3 0 C W H E X X 5 0 A 2 4 H W H E X X 0 1 A 2 4 H W H E X X 5 1 A 2 4 H W H E X X 0 2 A 4 0 H W H E X X 6 0...

Страница 27: ...C n r u t e R r e w o P r o t a l i t n e V l a i c r e m m o C X C 3 M F I E r e z i m o n o c E X 3 A F V R E t l o V 0 3 2 r o t a l i t n e V y r e v o c e R y g r e n E X 3 C F V R E t l o V 0 6...

Отзывы: