Manual 2100-392
Page 9
The following is a detailed explanation of each control
included in the Becket AFG Oil Burner, how each
operates, how to set up the burner, and how to
troubleshoot problems should they occur.
BECKETT “CLEANCUT” OIL PUMP
This oil pump is equipped with an oil solenoid valve
installed in the pump housing. This feature provides
quick cutoffs resulting in reduction in smoke after the
burner shuts down. This is a time proven pump design
and is capable of both one and two pipe systems. This
pump requires a pre-purge style primary control such as
the R7184B primary. All installation and set up
instructions are outlined in the “Oil Pump
Specification” section of the installation instructions
manual.
As an improved service feature Bard Manufacturing has
installed a brass tee fitting next to the oil line output of
the pump for installing a pressure gauge to ensure the
correct pump pressure. Refer to the “Burner Set Up and
Adjustment” section in the manual.
BECKETT SOLID STATE IGNITER
This igniter differs from the traditional iron core
transformer in that it produces a 14,000 volt spark
instead of a 10,000 volt spark of the iron core
BECKETT R7184B PRIMARY CONTROL
The R7184B Interrupted Electronic Oil Primary is a
line voltage, safety rated, interrupted ignition oil
primary control for residential oil burners. The R7184B
used with a cad cell flame sensor, operates the oil
burner and oil valve. The primary controls fuel oil,
senses flame, controls ignition spark and is designed to
notify a remote alarm circuit before going into lockout
when equipped with a flame monitoring system.
This primary control, though it possesses the latest
technology, is a very simple control to operate and
provides additional troubleshooting features to ease
service and reduce down time. Once the features and
operation of this control are understood the service
person will find it a welcomed addition. In an effort to
help in the transition to the R7184B primary control the
operational guide is provided following on Page 10.
transformer. This hotter spark provides for cleaner,
faster ignitions. Being solid state technology this
igniter is less susceptible to problems caused by voltage
variations. It also has a greater ability to ignite cold
and/or inconsistent oil. The solid state igniter is wired
to the primary control the same as a standard iron core
transformer.
Содержание FH085D36D