Bard 2100-737A Скачать руководство пользователя страница 8

Manual 2100-737A 

Page 

8 of 25

FIGURE 3

Mounting Instructions

D

16"

16"

16"

16"

16"

1

7 8

"

6

1 2

"

6

1 2

"

2

1 8

"

7 8

"

1"

3"

B

4" Typ.

6

1 2

"

30"

E

16"

A

C

C

3

1 8

"

4" Typ.

1 1/4

RE

TU

RN

 A

IR

1

2

DUCT

REQUIRE

D DIMENSIONS 

TO M

AINTAIN

1/4" MI

N. CLEAR

ANCE 

FROM

CO

M

BU

ST

IB

LE

 M

AT

ER

IA

LS

REQUIRE

D DIMENSIONS 

TO M

AINTAIN

RECOMM

ENDED 1" CLEA

RANCE FROM

CO

M

BU

ST

IB

LE

 M

AT

ER

IA

LS

A

B

C

D

E

30 1/2

10 1/2

6 1/4

29 3/4

32

12

5 1/2

2

29

OPENING

1

Re

tu

rn

 Op

en

ing

IT

 IS

 R

EC

OM

M

EN

DE

TH

AT

 A

 B

EA

D O

F

SU

PP

LY

 A

IR

NO

TE

S:

TOP FLASH

ING A

T T

IME OF INSTALLA

TION.

RAIN FLASHING

SI

LI

CO

NE

 C

AU

LK

IN

G B

E P

LA

CE

D B

EH

IN

D

THE SIDE MO

UNTI

NG F

LANGES AND UNDE

R

MIS-416 F

TOP.

WA

LL

FO

UR

 S

ID

ES

 O

SU

PP

LY

AIR DUC

T IS REQUIRED

WALL STRUCT

URE

FR

OM

 C

OM

BU

ST

AB

LE

1/

4"

 C

LE

AR

AN

CE

 O

N A

LL

M

AT

ER

IA

LS

HE

AT

ER

 A

CC

ES

S

PA

NE

L

FO

AM

 A

IR

 S

EA

L

Ri

ght 

Si

de V

iew

Wal

l Openi

ng and Hol

e Locat

ion V

iew

SU

PP

LI

ED

Supp

ly Ope

ning

SE

AL

 W

IT

H B

EA

D

OF CAULKING ALONG

ENTIRE LENGTH OF

TOP

2

Dimensi

on is 10" 

on TH/TS48-60*

Dimensi

on is 6" 

on TH/TS48-60*

Содержание 2100-737A

Страница 1: ...nted Packaged Heat Pump Models INSTALLATION INSTRUCTIONS Bard Manufacturing Company Inc Bryan Ohio 43506 www bardhvac com Manual 2100 737A Supersedes 2100 737 Date 5 14 21 T60H2 A T60H2 B T60H2 C Page...

Страница 2: ...tions 3 Wall Mount General Information 4 Heat Pump Wall Mount Model Nomenclature 4 Shipping Damage 4 General 4 Duct Work 5 Filters 5 Fresh Air Intake 5 Condensate Drain 5 Installation Instructions 6 W...

Страница 3: ...ummer Air Conditioning Duct Design for Residential ACCA Manual D Winter and Summer Air Conditioning and Equipment Selection For more information contact these publishers ACCA Air Conditioning Contract...

Страница 4: ...installation should be based on heat loss gain calculation made according to methods of Air Conditioning Contractors of America ACCA The air duct should be installed in accordance with the Standards...

Страница 5: ...factory for ordering information If using a return air filter grille filters must be of sufficient size to allow a maximum velocity of 400 fpm NOTE If no return air duct is used applicable installati...

Страница 6: ...lashing to wall and caulk across entire length of top See Figure 3 8 For additional mounting rigidity the return air and supply air frames or collars can be drilled and screwed or welded to the struct...

Страница 7: ...13 A Cond Air Inlet Electrical Entrances Optional Side Wall Mounting Brackets Built In Location Shipping Return Air Opening Supply Air Opening Top Rain Flashing Bottom Installation Bracket Back View...

Страница 8: ...3 4 32 12 5 1 2 2 29 OPENING 1 Return Opening IT IS RECOMMENDED THAT A BEAD OF SUPPLY AIR NOTES TOP FLASHING AT TIME OF INSTALLATION RAIN FLASHING SILICONE CAULKING BE PLACED BEHIND THE SIDE MOUNTING...

Страница 9: ...rials This is required for the first 3 of ducting It is important to insure that the 1 4 minimum spacing is maintained at all points Failure to do this could result in overheating the combustible mate...

Страница 10: ...IR FACTORY SUPPLIED RAIN FLASHING SUPPLY AIR MIS 548 A SIDE VIEW I A C K E 1 000 B 1 000 SUPPLY DUCT OVER FRAME INTERIOR FINISHED WALL ALL AROUND DUCT FRAMING MATERIAL EXTERIOR FINISH WALL OPENING FOR...

Страница 11: ...WALL OPENING W GRILLE SUPPLY DUCT MAYBE LOCATED IN AN ATTIC OR BELOW CEILING RAFTERS AS SHOWN CEILING RAIN RETURN AIR SLEEVE WALL SUPPLY AIR DUCT RAFTERS RAFTERS RETURN AIR OPENING W GRILLE RAIN FALSE...

Страница 12: ...t is to be used with the equipment The correct size must be used for proper circuit protection and also to assure that there will be no nuisance tripping due to the momentary high starting current of...

Страница 13: ...he correct set points NOTE The additional LAB low ambient bypass relay is required to prevent heater operation during low temperature cooling operation OPTIONAL COMPRESSOR CUTOFF THERMOSTAT See Figure...

Страница 14: ...at This is done to maximize efficiency by utilizing the heat pump to bring the conditioned space temperature up rather than cycling on the electric heat due a second stage call for heat from the therm...

Страница 15: ...ple leaks and recharges R 410A refrigerant is close to being an azeotropic blend it behaves like a pure compound or single component refrigerant The remaining refrigerant charge in the system may be u...

Страница 16: ...ONITOR All units with three phase scroll compressors are equipped with a three phase line monitor to prevent compressor damage due to phase reversal The phase monitor in this unit is equipped with two...

Страница 17: ...emperature sensor will send a signal to the heat pump control which will return the system to heating operations automatically If some abnormal or temporary condition such as a high wind causes the he...

Страница 18: ...as there is likely no actual frost on the outdoor coil in this artificial test condition There is also a 5 minute compressor time delay function built into the HPC This is to protect the compressor fr...

Страница 19: ...Heat pump control defective Check for 24 V between RV C and B C 1 Check circuit control wiring 2 Replace heat pump control Reversing valve solenoid coil defective Check for open or shorted coil Replac...

Страница 20: ...16 0 144374 22 0 43554 60 0 15310 98 0 6098 15 0 139576 23 0 42295 61 0 14921 99 0 5961 14 0 134956 24 0 41077 62 0 14544 100 0 5827 13 0 130506 25 0 39898 63 0 14177 101 0 5697 12 0 126219 26 0 3875...

Страница 21: ...y testing with this refrigerant charge quantity The following pressure tables show nominal pressures for the units Since many installation specific situations can affect the pressure readings this inf...

Страница 22: ...Minimum Circuit Ampacity Maximum Circuit Exterior Fuse or Circuit Breaker Field Power Wire Size Ground WIre Size Ckt A Ckt B Ckt C Ckt A Ckt B Ckt C Ckt A Ckt B Ckt C Ckt A Ckt B Ckt C T60H2 A00 A0Z A...

Страница 23: ...le filter Blower only CFM is the total air being circulated during continuous fan mode Airflow remains constant Blower only CFM reduces during continuous fan mode Requires wiring modification consult...

Страница 24: ...it s air noise cabinet duct or motor noise interview customer if necessary Air noise High static creating high blower speed Is airflow set properly Does removing filter cause blower to slow down Chec...

Страница 25: ...ite side of the connector plug and gently pulling the plug out of the connector socket in the control DO NOT PULL ON THE WIRES GRIP THE PLUG ONLY 6 The control module is now completely detached from t...

Отзывы: