5. Physical installation
5.3
Connecting the projector with the power net
W
ARNING
:
The total electrical installation should be protected by an appropriate rated and readily accessi-
ble disconnect switch, circuit breakers and ground fault current interrupters. The installation shall be done
according to the local electrical installation codes.
C
AUTION
:
ALL POWER CONNECTIONS to the ZEUS projector are made to the 3-slot terminal block located
in a sealed compartment behind the rear cover of the projector.
C
AUTION
:
The cross-sectional area of the conductors in the Power Supply Cord shall be not less than 2.5mm
2
(12AWG).
Necessary tools
•
Medium size
fl
at screw driver (4mm x 100mm).
•
Torque
fl
at screw driver (medium size).
•
Large size
fl
at screw driver (8mm x 150mm).
•
24mm open end wrench.
Necessary parts
Certi
fi
ed AC power supply cord 2.5mm
2
(12AWG), min. 300V. Take into account that the cable gland of the projector allows a cable
diameter from 8 to 13mm.
How to connect the main AC power with the ZEUS projector projector?
1. Remove the rear cover of the projector. See procedure "Removal of the rear cover", page 143.
2. Remove the cover of the main AC compartment by releasing the two captive thumb screws (reference 1 image 5-6) .
1
Image 5-6
3. Guide the AC power supply cord (reference 2 image 5-7) through the cable gland (reference 3 image 5-7) and connect the wires
to the 3-terminal strip (reference 6 image 5-7) as illustrated. Use a torque screw driver to fasten the screws of the 3-terminal strip
with a torque of
1.7Nm
(1.25 lbf*ft).
Warning:
Connect
fi
rst the PE wire (reference 4 image 5-7), then the other wires (reference 5 image 5-7).
Tip:
Check for good
fi
xation by pulling on each wire.
R5905961 ZEUS 09/03/2015
31
Содержание ZEUS
Страница 1: ...ZEUS Installation safety manual R5905961 00 09 03 2015 ...
Страница 17: ...2 Safety PR Image 2 2 R5905961 ZEUS 09 03 2015 13 ...
Страница 26: ...3 Getting started 22 R5905961 ZEUS 09 03 2015 ...
Страница 44: ...6 Lenses Lens selection 40 R5905961 ZEUS 09 03 2015 ...
Страница 84: ...10 Starting up 80 R5905961 ZEUS 09 03 2015 ...
Страница 96: ...11 Scheimpflug 92 R5905961 ZEUS 09 03 2015 ...
Страница 104: ...12 Convergence 100 R5905961 ZEUS 09 03 2015 ...
Страница 128: ...13 Lamp House Lamp replacement 124 R5905961 ZEUS 09 03 2015 ...
Страница 151: ...16 Removal and installation of the projector covers 2 3 A A C B Image 16 7 R5905961 ZEUS 09 03 2015 147 ...
Страница 160: ...16 Removal and installation of the projector covers 156 R5905961 ZEUS 09 03 2015 ...
Страница 176: ...18 Pin configurations 172 R5905961 ZEUS 09 03 2015 ...
Страница 184: ...19 Environmental information 180 R5905961 ZEUS 09 03 2015 ...