Restriction Zone (RZ) based on the HD
The HD depends on the amount of lumens produced by the projector and the type of lens installed. See
chapter
“HD in function of modifying optics”, page 18
To protect untrained end users (as cinema visitors, spectators) the installation shall comply with the following
installation requirements: Operators shall control access to the beam within the hazard distance or install the
product at a height that will prevent spectators' eyes from being in the hazard distance. Radiation levels in
excess of the limits will not be permitted at any point less than 2.0 meter (SH) above any surface upon which
persons other than operators, performers, or employees are permitted to stand or less than 1.0 meter (SW)
lateral separation from any place where such persons are permitted to be. In environments where
unrestrained behavior is reasonably foreseeable, the minimum separation height should be greater than or
equal to 3.0 meter to prevent potential exposure, for example by an individual sitting on another individual's
shoulders, within the HD.
These values are minimum values and are based on the guidance provided in IEC 62471-5:2015 section
6.6.3.5.
The installer and user must understand the risk and apply protective measures based upon the hazard
distance as indicated on the label and in the user information. Installation method, separation height, barriers,
detection system or other applicable control measure shall prevent hazardous eye access to the radiation
within the hazard distance.
For example, projectors that have a HD greater than 1 m and emit light into an uncontrolled area where
persons may be present should be positioned in accordance with “the fixed projector installation” parameters,
resulting in a HD that does not extend into the audience area unless the beam is at least 2.0 meter above the
floor level. In environments where unrestrained behavior is reasonably foreseeable, the minimum separation
height should be greater than or equal to 3.0 meter to prevent potential exposure, for example by an individual
sitting on another individual's shoulders, within the HD. Sufficiently large separation height may be achieved
by mounting the image projector on the ceiling or through the use of physical barriers.
RA
TH
HD
SW
SW
TOP VIEW
(B)
EXIT
SH
RA
PR
TH
HD
SIDE VIEW
(A)
RZ
H<SH
H>SH
LRZ
LRZ
RZ
Image 1–1
A
Side view
B
Top view
RA
Restricted Access location (boot area of projector).
TH
Theater
RZ
Restriction Zone in the theater
HD
Hazard Distance
LRZ
Length Restriction Zone in the theater
H
Height between surface floor and the light beam
SH
Separation Height
SW
Separation Width
Based on national requirements, no person is allowed to enter the projected beam within the zone between
the projection lens and the related hazard distance (HD). This shall be physically impossible by creating
sufficient separation height or by placing barriers. The minimum separation height takes into account the
surface upon which persons other than operator, performers or employees are permitted to stand.
On
a typical setup is displayed. It must be verified if these minimum requirements are met. If
required a restricted zone (RZ) in the theater must be established. This can be done by using physical barrier,
like a red rope as illustrated in
The restricted area sticker can be replaced by a sticker with only the symbol.
Содержание XDX Series
Страница 1: ...ENABLING BRIGHT OUTCOMES Installation manual XDX...
Страница 4: ......
Страница 19: ...19 R5914481 02 XDX 2 1 Conventions 20 2 2 Air flow 20 2 3 Web Communicator 21 System overview 2...
Страница 40: ...R5914481 02 XDX 40 Installation preparations...
Страница 70: ...R5914481 02 XDX 70 Starting the projector for the first time...
Страница 77: ...77 R5914481 02 XDX 5 Image 7 11 Locking the safety bracket Projector covers...
Страница 78: ...R5914481 02 XDX 78 Projector covers...
Страница 79: ...79 R5914481 02 XDX A 1 Dimensions of the projector 80 Dimensions A...
Страница 82: ...R5914481 02 XDX 82 Dimensions...
Страница 84: ...R5914481 02 XDX 84 Glossary...
Страница 86: ...R5914481 02 XDX 86 List of tools...
Страница 89: ......
Страница 90: ...www barco com R5914481 02 2022 03 16...