29
R5914477 /00
XDM
Power system
Power requirements
three-phase power net
•
200-240V/346-415V, 3W+N+PE, 9A, 50/60Hz (Y)
•
200-240V, 3W+PE, 11A, 50/60Hz (Δ)
single-phase power net
200-240 VAC, L1+N+PE, 14A, 50/60Hz
The projector must be switched internally between a star connection (Y), a delta connection (Δ) or a mono-
phase connection or vice versa. See
“
Connecting the projector with the power net
”
, page 49
The power cord required to connect the projector with the power net is not delivered with the projector. It is the
responsibility of the customer to provide the correct type of power cord. The cross-sectional area of the
conductors in the power supply cord shall not be less than 4 mm
2
(10 AWG).
In single-phase operation, the power cord must be rated for
minimum 300 V
.
In three-phase operation, the power cord must be rated for
minimum 300 V
in case of a 3W+PE (208V) power
system, and
minimum 500 V
in case of a 3W+N+PE (230/400 V) power system. For a 3W+PE system, 208 V
is measured between the lines. For a 3W +N +PE system, 400 V is measured between the lines, 230 V is
measured between the lines and the neutral.
To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommends that
the instrument panel and cabinet be grounded. In no event shall this projector be operated without an
adequate cabinet ground connection.
The AC supply must be installed by a qualified electrician in conformance to local codes. Hardware, wire sizes
and conduit types must comply with local codes.
A readily accessible disconnect device shall be incorporated externally to the equipment for removal of the
power to the equipment mains terminals.
The building installation must be provided with a circuit breaker of max. 40 A to protect the complete unit.
WARNING:
Disconnect the power to the unit mains terminals for removal of all power from the unit.
UPS requirements
The Uninterruptible Power Supply (UPS), also known as a Continuous Power Supply (CPS), must have an
output voltage of 200-240 V at 50/60 Hz and must be capable of delivering an output current of 5 A. This UPS
provides only power for the electronics and not for the light source.
The connection between the UPS unit and the UPS inlet of the projector must be done with a certified AC
power supply cord of minimum 1,50 mm² or 14 AWG and minimum 300 V.
The XDM does not have a built in UPS unit.
Projector weight
Do not underestimate the weight of the XDM projector. The projector weight ±140 kg (±309 lbs) without lens.
Ensure that the pedestal on which the projector is installed is capable of supporting the complete load of the
system. To prevent personal injury a hoisting tool must be used to lift the projector.
CAUTION:
An external frame must be used to stack projectors.
Содержание XDM
Страница 1: ...ENABLING BRIGHT OUTCOMES Installation manual XDM ...
Страница 4: ......
Страница 26: ...R5914477 00 XDM 26 System overview ...
Страница 44: ...R5914477 00 XDM 44 Installation preparations ...
Страница 66: ...R5914477 00 XDM 66 Installation procedures ...
Страница 80: ...R5914477 00 XDM 80 Starting the projector for the first time ...
Страница 88: ...R5914477 00 XDM 88 5 Image 6 12 Locking the safety bracket Projector covers ...
Страница 90: ...R5914477 00 XDM 90 Projector covers ...
Страница 96: ...R5914477 00 XDM 96 Dimensions ...
Страница 98: ...R5914477 00 XDM 98 Glossary ...
Страница 102: ...R5914477 00 XDM 102 List of tools ...
Страница 103: ......
Страница 104: ...www barco com R5914477 00 2021 10 26 ...