The electronics of the projector are fan cooled. For that the projector must be installed with sufficient space
around the projector, minimum 20 cm (8 inch) to ensure sufficient air flow. It should be used in an area where
the ambient temperature, as measured at the projector air inlet, does not exceed 30°C (86°F).
Projection rooms must be well ventilated or cooled in order to avoid build up of heat. It is necessary to vent hot
exhaust air from projector and cooling system (chiller unit) to the outside of the building. The minimum flow
rate of the air extraction system depends on the ambient temperature:
Thor+
Ambient temperature
Minimum airflow per system
30°C (86°F)
370 l/s (790 CFM)
25°C (77°F)
280 l/s (590 CFM)
20°C (68°F)
225 l/s (475 CFM)
Thor
Ambient temperature
Minimum airflow per system
30°C (86°F)
280 l/s (590 CFM)
25°C (77°F)
210 l/s (440 CFM)
20°C (68°F)
166 l/s (350 CFM)
Where two projectors or more are installed close to each other, ensure that the projectors do not thermally
affect each other.
Dew point
The dew point is the saturation temperature for water in air. The dew point is associated with
relative humidity. A high relative humidity implies that the dew point is closer to the current air
temperature. Relative humidity of 100% indicates the dew point is equal to the current temperature
and that the air is maximally saturated with water. When the moisture content remains constant and
temperature increases, relative humidity decreases.
Condensed water drain requirements
The projector is equipped with air dryers to remove moisture from the sealed compartments. The condensed
water collected by the air dryers is removed from the projector through small drain tubes at the bottom of the
projector. It's most efficient and recommended to guide the small drain tubes directly to a water drain.
•
A vertical air gap fitting must be installed between the small drain tubes and the building drain! Note that
the end of the small drain tubes must be in free air (not airtight taped off) to prevent back flow.
•
The minimum downwards slope over the whole length of the small drain tubes is 15 cm per meter (1.8 inch
per foot). It's recommended to guide the small drain tubes vertically for optimal flow. Clogging is often the
result of improper slope (sloping uphill).
•
The maximum allowed length of the small drain tubes (Ø8 mm) before ending into the water drain is 2.5
meter (8 feet).
•
If no water drain is available then an 'open' water container can be installed to capture the condensed
water coming out of the small drain tubes. The volume of the water container depends on the humidity
level of the operation environment. In most applications a water container with a volume of 5 liter should be
sufficient if emptied regularly.
Main Power requirements
The Thor series projector operates from a nominal 3W+N+PE or 3W+PE power net. The projector must be
switched internally between a star connection to a delta connection or vice versa. See installation instructions.
•
Electrical ratings for Star system (3W+N+PE):
-
The cross-sectional area of the conductors in the power supply cord shall be 4mm
2
to 6mm
2
, 10AWG to
8AWG.
-
The electrical rating of the Thor+ projector is 200-240V/346-415V 3W+N+PE 16A 50-60Hz (Y
connection) (Y connection).
-
The electrical rating of the Thor projector is 200-240V/346-415V 3W+N+PE 10A 50-60Hz (Y
connection) (Y connection).
-
The building installation has to be provided with a circuit breaker of range 25A to 40A to protect the
complete unit.
Содержание Thor Series
Страница 1: ...ENABLING BRIGHT OUTCOMES Installation manual Thor series...
Страница 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com...
Страница 8: ...R5906788 03 Thor series 8...
Страница 24: ...R5906788 03 Thor series 24 Safety Information...
Страница 26: ...R5906788 03 Thor series 26 Commander Web Commander System overview...
Страница 44: ...R5906788 03 Thor series 44 Installation process...
Страница 68: ...R5906788 03 Thor series 68 Lenses Lens selection...
Страница 78: ...R5906788 03 Thor series 78 Installing a HDD into the ICMP ICMP...
Страница 110: ...R5906788 03 Thor series 110 Starting up...
Страница 122: ...R5906788 03 Thor series 122 Scheimpflug...
Страница 130: ...R5906788 03 Thor series 130 Convergence...
Страница 142: ...R5906788 03 Thor series 142 Preventative maintenance actions...
Страница 160: ...R5906788 03 Thor series 160 Specifications...
Страница 168: ...R5906788 03 Thor series 168 Pin configurations...
Страница 172: ...R5906788 03 Thor series 172 Environmental information...
Страница 176: ...Glossary R5906788 03 Thor series 176...
Страница 181: ...R5906788 03 Thor series 181...
Страница 182: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5906788 03 07 09 2018...