background image

SP-20

Installation manual

R59770294/02
11/02/2009

Содержание SP-20

Страница 1: ...SP 20 Installation manual R59770294 02 11 02 2009 ...

Страница 2: ...Barco nv Media Entertainment Division Noordlaan 5 B 8520 Kuurne Phone 32 56 36 89 70 Fax 32 56 36 883 86 E mail sales events barco com Visit us at the web www barco com Printed in China ...

Страница 3: ... any complaints The period of guarantee begins on the date of transfer of risks in the case of special systems and software on the date of commissioning at latest 30 days after the transfer of risks In the event of justified notice of complaint Barco can repair the fault or provide a replacement at its own discretion within an appropriate period If this measure proves to be impossible or unsuccess...

Страница 4: ......

Страница 5: ...21 3 8 Control software 23 3 9 Fiberlink system 24 4 Proper and safe use of the foot system 25 4 1 Folding out the foot system into the 80 stand 26 4 2 Changing from the 80 to the 90 stand 28 4 3 Folding in the foot system 30 5 Physical installation 33 5 1 Securing SP 20 tiles 34 5 2 Installing soft covers on gateways 36 6 Cabling 39 6 1 Power cabling of a SP 20 tile 40 6 2 Data cabling of a SP 20...

Страница 6: ...Table of contents 2 R59770294 SP 20 11 02 2009 ...

Страница 7: ... the SP 20 tile Ensure that you understand and follow all safety guidelines safety instructions and warnings mentioned in this chapter before installing the SP 20 display After this chapter addi tional warnings and cautions are given depending on the installation procedure Read and follow these warnings and cautions as well Overview Safety guidelines Important safety instructions Important warning...

Страница 8: ... and manufacturing processes in order to achieve part strength Consult Barco for assistance with custom applications Always follow Barco installation instructions Contact Barco if you should have any question regarding the safety of an application The manufacturer assumes no liability for incorrect inadequate irresponsible or unsafe assembly of systems Product care Structural mounting components s...

Страница 9: ...tive parts must be undertaken immediately Protect the power data cords from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Replace damaged power data cords immediately Only use attachments accessories specified by the manufacturer Disconnect the power to this apparatus during lightning storms or provide suitable additional ...

Страница 10: ...t device shall be incorporated in the fixed wiring This equipment MUST be earthed In order to protect against risk of electric shock the installation should be properly grounded Defeating the purpose of the grounding type plug will expose you to the risk of electric shock Power system It is recommended to use a TN S power distribution system a power distribution system with a separate neutral and ...

Страница 11: ...l requirements to install the SP 20 display the electrical requirements to power up the SP 20 display and the system requirements to efficiently run the control software for the SP 20 Overview Mechanical requirements Electrical requirements System requirements for the Control software R59770294 SP 20 11 02 2009 7 ...

Страница 12: ...ch other the foot system is equipped with locks which can be operated by hand or foot so no tools are required to install the SP 20 sports perimeter 1 2 1 2 Image 2 1 WARNING Make sure that neighboring tiles are always firmly secured with both locks see Foot system page 12 WARNING Make sure that both side of gateways in the SP 20 sports perimeter are always provided with a soft cover see Soft cove...

Страница 13: ...al and grounding conductor in order to avoid large ground current loops due to voltage differences in the neutral conductor The total electrical installation should be protected by an appropriately rated disconnect switch circuit breakers over voltage protector and Ground Fault Current Interrupters The installation shall be done according to the local electrical installation codes In Europe specia...

Страница 14: ...lent 2 GHz 512 Mb RAM Free hard disk space 300 Mb XGA resolution 1024 x 768 Serial communication port Ethernet connection Software Windows 20001 Windows XP Home or Windows XP Professional Recommended specifications Hardware PC Pentium IV or equivalent 2 4 GHz 1 Gb RAM 300 Mb hard disk free space SXGA resolution 1280 x 1024 with 32 Mb video memory Serial communication port Ethernet connection Softw...

Страница 15: ...boxes digitizer fiberlink compact link and control software we refer to the manual of these components for more information about use and installation Block diagram of the SP 20 display Digitizer Control PC Power box Sources SP 20 tile SP 20 tile SP 20 tile SP 20 tile SP 20 tile SP 20 tile Image 3 1 Overview Foot system SP 20 tile Soft cover External handles SP 20 package Power boxes Digitizer Con...

Страница 16: ...t foot When looking from the back side of the SP 20 tile you can notice that the right foot is equipped with 2 locks These locks are used to connect two neighboring tiles Image 3 2 Why need a foot system For optimal view upon the SP 20 sports perimeter the foot system can provide two different angles of inclination 80 or 90 10o Image 3 3 12 R59770294 SP 20 11 02 2009 ...

Страница 17: ...ed with number 2 makes sure that both feet fall down and are ready to be positioned in the 80 or 90 position 1 1 2 Image 3 4 WARNING Read the installation procedure and safety tips mentioned in this manual on how to operate the foot system see chapter 4 Proper and safe use of the foot system Proper and safe use of the foot system page 25 R59770294 SP 20 11 02 2009 13 ...

Страница 18: ...t of the tile tilt 10 without tools Furthermore this foot system can be folded up to reduce the volume of the tile for transportation The LED side of the SP 20 tile is equipped with soft shaders to prevent injury and can easily be replaced in case of damage 10o Image 3 5 Part location of the SP 20 tile 1 2 5 8 10 4 3 6 11 12 9 7 20 13 19 17 15 14 16 18 Image 3 6 14 R59770294 SP 20 11 02 2009 ...

Страница 19: ... 9 Power and data Input Output ports of the controller re sync unit 10 Air inlet 11 Air inlet 12 Mounting pin for the foot system 13 Lower lock of the left door 14 Door handle 15 Carrying handle 16 Air outlet 17 Air outlet 18 Upper lock of the left door 19 Mounting pin for the foot system 20 Replaceable shaders Part location of the SP 20 tile with foot system 1 2 3 4 6 7 8 5 Image 3 7 R59770294 SP...

Страница 20: ... to be sealed with a dummy power plug Image 3 8 Power link cable of 1 5 meter R9850241 Image 3 9 Power link cable of 4 5 meter R9850250 Image 3 10 Power link cable of 9 meter R9850260 Image 3 11 Dummy power plug R9850280 Data cables used between SP 20 tiles To meet the demands of each SP 20 application Barco offers several lengths of data cables to link data from tile to tile Note that the data ou...

Страница 21: ... covers which can be used to put on the SP 20 tiles who are used to make a gateway inside the SP 20 sports perimeter These soft covers prevent possible injuries after contact or impact with the SP 20 sports perimeter Image 3 15 R838032 and R838033 Image 3 16 R59770294 SP 20 11 02 2009 17 ...

Страница 22: ...les General use Barco offers a set of handles which make it easier and safer to lift move and position the SP 20 tiles Slide in the handles on both sides of the SP 20 tile as illustrated below Image 3 17 R838361 Image 3 18 18 R59770294 SP 20 11 02 2009 ...

Страница 23: ... the SP 20 tiles are stored in a secure way SP 20 tiles can be stored in two different types of package A big package contains three SP 20 tiles a small package contains only one SP 20 tile Image 3 19 The foot system is already attached to the SP 20 tiles R59770294 SP 20 11 02 2009 19 ...

Страница 24: ...be used several sizes and types of power distributions are available from Barco For smaller system the Mono Phase Power Box can be used medium sized system may use on of several custom power box solutions Image 3 20 Mono phase power box Image 3 21 Custom power box CAUTION Consult the manual s of the used power box for more information about installation and usage guidelines 20 R59770294 SP 20 11 0...

Страница 25: ...her overlay them customize them With analog and digital outputs which allow for the control of displays as well as built in control software the D320 gives you control over everything from basic set up to configuration and advanced feature control The D320 digitizer is a generic device This means that a number of combinations can be made Devices can be chained in order to generate more windows on ...

Страница 26: ...3 Components of the SP 20 display Image 3 24 Director Toolset version 2 0 or later is required 22 R59770294 SP 20 11 02 2009 ...

Страница 27: ... to set up configure manage and control all D320 and DX 700 based systems with scalable and expandable functionality for all users on all platforms Image 3 25 CAUTION Refer to the manual s of the used control software for more information about installation and usage guidelines R59770294 SP 20 11 02 2009 23 ...

Страница 28: ... signal integrity and system reliability Barco offers two complete system solutions including transmitter fiber and receiver The choice of system depends on the length of cable required Image 3 26 Fiberlink 2 transmitter and receiver CAUTION Refer to the manual s of the used fiberlink system for more information about installation and usage guidelines 24 R59770294 SP 20 11 02 2009 ...

Страница 29: ...he foot system WARNING Pay special attention to the warnings and tips mentioned in this chapter WARNING Use the procedures described in this chapter to reduce the risk of injuries to a minimum Overview Folding out the foot system into the 80 stand Changing from the 80 to the 90 stand Folding in the foot system R59770294 SP 20 11 02 2009 25 ...

Страница 30: ...Make sure you are positioned between the feet so you can not be hurt when the feet fall down PULL PULL Image 4 1 2 The feet are now positioned as illustrated below Push the tile forward until the guiding pin has fallen into the first groove of booth feet Note The first groove is indicated with the red circle Warning Do not push the tile further forward then necessary Doing so can damage the shader...

Страница 31: ...4 Proper and safe use of the foot system Image 4 2 3 Gently bring down the SP 20 tile until both feet are positioned on the ground Image 4 3 R59770294 SP 20 11 02 2009 27 ...

Страница 32: ...tile It is recommended to use the external handles for this operation see chapter 3 Components of the SP 20 display External handles page 18 How to change from the 80 to the 90 stand 1 Lift the SP 20 tile so both feet can fall down If necessary use your foot to push the foot system out of the first groove 1 2 Image 4 4 2 Guide the foot system with your foot until the guiding pin has fallen into th...

Страница 33: ...4 Proper and safe use of the foot system 1 2 Image 4 5 R59770294 SP 20 11 02 2009 29 ...

Страница 34: ...l handle and put the other hand on top of the SP 20 tile It is recommended to use the external handles for this operation see chapter 3 Components of the SP 20 display External handles page 18 How to fold in the foot system 1 Lift the SP 20 tile so both feet can fall down If necessary use your foot to push the foot system out of the groove 1 2 Image 4 6 2 Fold in both foot systems using your foot ...

Страница 35: ...4 Proper and safe use of the foot system 1 CLICK 2 Image 4 7 R59770294 SP 20 11 02 2009 31 ...

Страница 36: ...4 Proper and safe use of the foot system 32 R59770294 SP 20 11 02 2009 ...

Страница 37: ...ed tilt angle and positioning them next to the previous tile inside the SP 20 sports perimeter For more information about this procedure see Proper and safe use of the foot system page 25 3 The following stage describes how to connect one SP 20 tile to a neighboring tile For detailed information see Securing SP 20 tiles page 34 4 If used the next stage is to provide soft covers to the sides of the...

Страница 38: ...lign both tiles 2 Close the top lock using the procedure illustrated below Note This procedure has to be carried out by hand 1 2 3 4 Image 5 1 3 Close the bottom lock using the procedure illustrated below Note This procedure can be performed by foot 34 R59770294 SP 20 11 02 2009 ...

Страница 39: ...5 Physical installation 1 2 3 4 Image 5 2 R59770294 SP 20 11 02 2009 35 ...

Страница 40: ... a soft cover 1 Loosen the nut reference A until you can pull back the foot system Warning Only partially loosen the nut until you have enough space to insert he soft cover A Image 5 3 2 Insert the soft cover as illustrated Note Not that only for the clearness of the illustration below the foot system has been completely removed Image 5 4 3 Fasten the nut reference A 36 R59770294 SP 20 11 02 2009 ...

Страница 41: ...5 Physical installation Image 5 5 R59770294 SP 20 11 02 2009 37 ...

Страница 42: ...5 Physical installation 38 R59770294 SP 20 11 02 2009 ...

Страница 43: ...NG The outdoor input and output sockets for SP 20 tiles can only be used in conjunction with Barco s outdoor cables for LED walls Do not use any other cables than those specified WARNING Dummy plugs must be placed on unused outdoor input and output sockets of SP 20 tiles and all plug holder clamps must be locked firmly WARNING Make sure that the connector sockets are provided with sealing rings be...

Страница 44: ...How to realize the power cabling of the SP 20 display 1 Install the power box nearby the TF 20 display Ensure the power box provides as much power circuits as required to power the display in a safe manner If necessary install several power boxes See manual of the used power box for installation instructions 2 Connect a power source cable coming from the power box with the first tile in the SP 20 ...

Страница 45: ...lder clamps are locked firmly 5 Specify in the setup controlling software how the data path is realized and which tile is the first in the chain WARNING When using a fiberlink system the fiberlink data connection is inserted between the digitizer and the first SP 20 tile The fiberlink receiver is also equipped with Barco s outdoor connector sockets Example of data cabling F E A D C B DIGITIZER LED...

Страница 46: ...6 Cabling 42 R59770294 SP 20 11 02 2009 ...

Страница 47: ...7 Maintenance 7 MAINTENANCE Overview Cleaning SP 20 tiles R59770294 SP 20 11 02 2009 43 ...

Страница 48: ...es 1 Seal up the data and power sockets using a power and data linking cable Make sure that all plug holder clamps are locked firmly 2 Vaporize through different directions the window cleaning product on the shaders and LED s Warning Do not use industrial grease removers Use only materials or chemicals that are inert nonabrasive noncorrosive and non marking 3 Brush down all dirt of the LED s and t...

Страница 49: ...8 Order info 8 ORDER INFO Overview Order info R59770294 SP 20 11 02 2009 45 ...

Страница 50: ...fo 8 1 Order info Order info for the SP 20 sports perimeter Description Article number SP 20 tile R9004818 External handles R838361 Left soft cover R9870024 Right soft cover R9870025 46 R59770294 SP 20 11 02 2009 ...

Страница 51: ...A Dimensions A DIMENSIONS Overview Dimensions of the SP 20 tile R59770294 SP 20 11 02 2009 47 ...

Страница 52: ... Dimensions A 1 Dimensions of the SP 20 tile Dimensions of the tile 960 285 9 840 960 947 Image A 1 Dimensions of the foot system 665 08 981 35 737 15 10 o 966 89 Image A 2 48 R59770294 SP 20 11 02 2009 ...

Страница 53: ...B Specifications of the SP 20 tile B SPECIFICATIONS OF THE SP 20 TILE Overview Specifications of the SP 20 tile R59770294 SP 20 11 02 2009 49 ...

Страница 54: ...7 600 NIT Color Processing 16 bit Contrast ratio 3 000 1 Dimensions Width 960mm tile Height 960mm tile Depth 250mm tile Hor viewing angle 120 LED configuration 1R 1G 1B discrete LED density 7 500 LEDs m Pixel pitch 20mm Power Average 120W tile Maximum 370W tile Vert viewing angle 15 40 Weight 54kg 50 R59770294 SP 20 11 02 2009 ...

Страница 55: ...n Documentation Noordlaan 5 B 8520 Kuurne Phone 32 56 36 89 70 Fax 32 56 36 88 24 E mail service mne barco com Web www barco com From Date Please correct the following points in this documentation R59770294 02 page wrong correct R59770294 SP 20 11 02 2009 ...

Отзывы: