3. Installation requirements
3.2
Electrical requirements for the SF-10V display
Power requirements
One SF-10V tile requires 220-240 VAC, 50-60 Hz, 4.32 amps at 230 VAC. Note that one SF-10V tile correspond with a display surface
of 1,23 m². Power link cables are used to link the power from tile to tile. However, MAXIMUM three (3) tiles, may be connected in
parallel. So, one power source cable has to be provided per three (3) tiles. Every power source cable should be protected by a
circuit breaker or fuses rated 16 A / 250 VAC (15 A / 250 VAC in the USA and Canada).
Barco provides a range of power boxes, which meet the requirements of your SF-10V display. Contact Barco
for more information about power boxes and power requirements for your SF-10V display.
Power system
It is recommended to use a TN-S power distribution system (a power distribution system with a separate neutral and grounding
conductor) in order to avoid large ground current loops due to voltage differences in the neutral conductor. The total electrical
installation should be protected by an appropriately rated disconnect switch, circuit breakers, over voltage protector and Ground Fault
Current Interrupters. The installation shall be done according to the local electrical installation codes. In Europe special attention
should be given to EN 60364, the standard for electrical installation of buildings. In Germany VDE 0100 should be adhered to. In
America, special attention should be given to the National Electrical Code, ANSI/NFPA 70.
This equipment MUST be earthed
In order to protect against risk of electric shock, the installation should be properly grounded. Defeating the purpose of the grounding
type plug will expose you to the risk of electric shock.
R59770542 SF-10V DISPLAY 03/12/2010
13
Содержание SF-10V
Страница 1: ...SF 10V display Installation manual R59770542 00 03 12 2010 ...
Страница 4: ......
Страница 6: ...Table of contents 2 R59770542 SF 10V DISPLAY 03 12 2010 ...
Страница 14: ...2 SF 10V tiles 10 R59770542 SF 10V DISPLAY 03 12 2010 ...
Страница 23: ...4 System overview Image 4 4 Power cable Z3472564 R59770542 SF 10V DISPLAY 03 12 2010 19 ...
Страница 25: ...4 System overview Image 4 6 Data cable Z3472565 R59770542 SF 10V DISPLAY 03 12 2010 21 ...
Страница 26: ...4 System overview Image 4 7 Dummy data connector 22 R59770542 SF 10V DISPLAY 03 12 2010 ...
Страница 38: ...5 Physical installation 34 R59770542 SF 10V DISPLAY 03 12 2010 ...
Страница 43: ...7 Specification 7 SPECIFICATION R59770542 SF 10V DISPLAY 03 12 2010 39 ...
Страница 44: ...7 Specification 40 R59770542 SF 10V DISPLAY 03 12 2010 ...