background image

1. Safety

1.3

Important warnings

Important warnings:

Risk of electric shock:

Do not open. To reduce the risk of electric shock, do not remove cover (or back). No user-serviceable parts inside. Refer servicing
to quali

fi

ed service personnel.

Maximum and minimum ambient temperature:

The maximum ambient temperature for the LED wall is 40°C, the minimum temperature is -20°C.

High leakage current:

The combination of multiple tiles in an installation results in increased levels of leakage current. In order to avoid risk of electric
shock due to high leakage current, proper grounding of the installation is required.

Flammable materials:

Keep

fl

ammable materials away from the installation (such as curtains). A lot of energy is transferred into heat. The installation

should be such that the amount of air

fl

ow required for safe operation of the equipment is not compromised. Proper ventilation must

be provided.

Risk of electric shock / Risk of

fi

re:

To protect against risk of

fi

re caused by overloading of power cables, MAXIMUM 3 tiles may be connected in parallel. Each power

source cable supplying maximum 3 tiles should be protected by a circuit breaker or fuses rated 16 A / 250 VAC (15 A / 250 VAC in
the USA and Canada). Note that one SF-10V tile requires 220-240 VAC, 50-60 Hz, 1.56 amps at 230 VAC.

Disconnect device:

When the appliance inlets of the individual tiles are not accessible, the socket outlets supplying the rack shall be installed near the
equipment and be easily accessible, or a readily accessible general disconnect device shall be incorporated in the

fi

xed wiring.

This equipment MUST be earthed:

In order to protect against risk of electric shock, the installation should be properly grounded. Defeating the purpose of the grounding
type plug will expose you to the risk of electric shock.

Power system:

It is recommended to use a TN-S power distribution system (a power distribution system with a separate neutral and grounding
conductor) in order to avoid large ground current loops due to voltage differences in the neutral conductor. The total electrical
installation should be protected by an appropriately rated disconnect switch, circuit breakers, over voltage protector and Ground Fault
Current Interrupters. The installation shall be done according to the local electrical installation codes. In Europe special attention
should be given to EN 60364, the standard for electrical installation of buildings. In Germany VDE 0100 should be adhered to. In
America, special attention should be given to the National Electrical Code, ANSI/NFPA 70.

Mains cords:

The power cords delivered with this system have special properties for safety. They are not user serviceable. If the power cords are
damaged, replace them only with new ones. Never try to repair a power cord.

Data cables:

The data cables provided with this system have special properties for safety. They are not user serviceable. If the data cables are
damaged, replace them only with new ones. Never try to repair a data cable. Per requirements of the National Electrical Code®
in the USA , the length of a data cable must not exceed 42 m (140 feet). Avoid exposure of data cables to accidental contact with
lightning or power conductors.

Salty environment

If install in coastal cities, the SF-10V display shall be installed 250 meters away from the shoreline horizontally in dry and cold
climates; 500 meters away from the shoreline in case of high humidity and hot climates. The high humidity and hot climate mean
the climate that the humidity is higher than 80% RH and temperature is higher than 0°C for one third of time every

6

R59770542 SF-10V DISPLAY 03/12/2010

Содержание SF-10V

Страница 1: ...SF 10V display Installation manual R59770542 00 03 12 2010 ...

Страница 2: ...Barco nv Events Noordlaan 5 B 8520 Kuurne Phone 32 56 36 82 11 Fax 32 56 36 88 24 Support www barco com esupport Visit us at the web www barco com Printed in Belgium ...

Страница 3: ...ess for a particular purpose Barco may make improvements and or changes to the product s and or the program s described in this publication at any time without notice This publication could contain technical inaccuracies or typographical errors Changes are periodically made to the information in this publication these changes are incorporated in new editions of this publication ...

Страница 4: ......

Страница 5: ... 3 3 System requirements for the Control software 14 4 System overview 15 4 1 Introduction 16 4 2 SF 10V tile 18 4 3 Power boxes 23 4 4 Video Processor 24 4 5 Control software 26 5 Physical installation 27 5 1 Installation of the support structure 28 5 2 Mounting the SF 10V tile 29 6 Dimensions 35 6 1 SF 10V tile 36 6 2 Assembly of SF 10V tiles 37 6 3 SF 10V package 38 7 Specification 39 7 1 Speci...

Страница 6: ...Table of contents 2 R59770542 SF 10V DISPLAY 03 12 2010 ...

Страница 7: ... 10V tile Ensure that you understand and follow all safety guidelines safety instructions and warnings mentioned in this chapter before installing the SF 10V display After this chapter additional warn ings and cautions are given depending on the installation procedure Read and follow these warnings and cautions as well Overview Safety guidelines Important safety instructions Important warnings R59...

Страница 8: ...e any component Barco uses specific materials and manufacturing processes in order to achieve part strength Consult Barco for assistance with custom applications Always follow Barco installation instructions Contact Barco if you should have any question regarding the safety of an application The manufacturer assumes no liability for incorrect inadequate irresponsible or unsafe assembly of systems ...

Страница 9: ...parts must be undertaken immediately Protect the power data cords from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Replace damaged power data cords immediately Only use attachments accessories specified by the manufacturer Disconnect the power to this apparatus during lightning storms or provide suitable additional light...

Страница 10: ...the purpose of the grounding type plug will expose you to the risk of electric shock Power system It is recommended to use a TN S power distribution system a power distribution system with a separate neutral and grounding conductor in order to avoid large ground current loops due to voltage differences in the neutral conductor The total electrical installation should be protected by an appropriate...

Страница 11: ... tiles 2 SF 10V TILES About this chapter This chapter describes the SF 10V tiles which can be used to assemble SF 10V display Overview SF 10V tile Stacking SF 10V packages R59770542 SF 10V DISPLAY 03 12 2010 7 ...

Страница 12: ...back view of the SF 10V tile Image 2 1 Packing For safe transportation the SF 10V tiles are stored in a secure way 4 SF 10V tiles can stand in a big wooden pallet Image 2 2 Total package weight SF 10V 4 tile package 355 kg 8 R59770542 SF 10V DISPLAY 03 12 2010 ...

Страница 13: ...F 10V packages Stacking possibilities for SF 10V packages Image 2 3 WARNING Only the configurations illustrated above can be used for stacking Other configurations will dam age the SF 10V tiles R59770542 SF 10V DISPLAY 03 12 2010 9 ...

Страница 14: ...2 SF 10V tiles 10 R59770542 SF 10V DISPLAY 03 12 2010 ...

Страница 15: ... the SF 10V display the electrical requirements to power up the SF 10V display and the system requirements to run the control software efficient Overview Mechanical requirements for the SF 10V display Electrical requirements for the SF 10V display System requirements for the Control software R59770542 SF 10V DISPLAY 03 12 2010 11 ...

Страница 16: ... a systems viability consult Barco for advice on profes sional rigging organizations Individual basis Support structures must be assessed on an individual basis Never construct a wall if there is uncertainty regarding the stability of an installation or the load holding capabilities If there are doubts on a system s viability consult Barco for advise on professional rigging organizations Example o...

Страница 17: ... use a TN S power distribution system a power distribution system with a separate neutral and grounding conductor in order to avoid large ground current loops due to voltage differences in the neutral conductor The total electrical installation should be protected by an appropriately rated disconnect switch circuit breakers over voltage protector and Ground Fault Current Interrupters The installat...

Страница 18: ... specifications Hardware PC Pentium III or equivalent 2 GHz 512 Mb RAM Free hard disk space 300 Mb XGA resolution 1024 x 768 Serial communication port Ethernet connection Software Windows XP Home or Windows XP Professional Recommended specifications Hardware PC Pentium IV or equivalent 2 4 GHz 1 Gb RAM 300 Mb hard disk free space SXGA resolution 1280 x 1024 with 32 Mb video memory Serial communica...

Страница 19: ...EM OVERVIEW About this chapter This chapter enumerates the fundamental elements of an SF 10V screen display Overview Introduction SF 10V tile Power boxes Video Processor Control software R59770542 SF 10V DISPLAY 03 12 2010 15 ...

Страница 20: ... SF 10V tiles Control PC Digitizer Power box Control software Block diagram of a SF 10V display Sources Digitizer Control PC Power box RS232 Tile 1 LED wall Tile 2 Tile 3 Image 4 1 If the digitizer is D320 or Ledpro use the RS232 connection with the control PC 16 R59770542 SF 10V DISPLAY 03 12 2010 ...

Страница 21: ...rview Sources Digitizer Control PC Power box TCP IP Tile 1 LED wall Tile 2 Tile 3 Image 4 2 If the digitizer is DX 700 and DX 100 use the TCP IP connection with the control PC R59770542 SF 10V DISPLAY 03 12 2010 17 ...

Страница 22: ...front of side and an IP43 rating in back of side Parts location of the SF 10V tile 2 3 4 5 9 5 11 5 4 11 1 12 6 8 9 3 8 7 1 8 10 10 7 6 2 6 6 8 4 5 Image 4 3 1 Adjust block 2 Data connector 3 Mounting pin 4 Handle 5 Insert nuts for fixing tile 6 Hinge 7 Air outlet 8 Lock 9 Hidden handle 10 Air inlet 11 Power connector 12 Frame Power cables used between SF 10V tiles To meet the demands of each SF 1...

Страница 23: ...4 System overview Image 4 4 Power cable Z3472564 R59770542 SF 10V DISPLAY 03 12 2010 19 ...

Страница 24: ...s To meet the demands of each SF 10V application Barco offers several lengths of data cables to link data from tile to tile Note that the data output port of the last SF 10V tile in the data chain has to be sealed with a dummy data plug 20 R59770542 SF 10V DISPLAY 03 12 2010 ...

Страница 25: ...4 System overview Image 4 6 Data cable Z3472565 R59770542 SF 10V DISPLAY 03 12 2010 21 ...

Страница 26: ...4 System overview Image 4 7 Dummy data connector 22 R59770542 SF 10V DISPLAY 03 12 2010 ...

Страница 27: ...e used Though 3rd party solutions may be used below size and type of power distributions are available from Barco Below system may use on of several custom power box solutions Image 4 8 Custom power box CAUTION Consult the manual s of the used power box for more information about installation and usage guidelines R59770542 SF 10V DISPLAY 03 12 2010 23 ...

Страница 28: ... and control The video processor can be accessed directly or via the control software e g DTS This software is designed as a user interface to be used in conjunction with the Video processor and display It should be used on a PC that s connected to the Video processor through a serial RS232 connection SF 10V Video Processor Overview Image 4 9 D320 Processor Image 4 10 DX 700 Processor Image 4 11 L...

Страница 29: ... the devices to multiple screens For latter purpose each input is equipped with an active loop through Analog Video Digital Video Formated Video Data Master Slave SOURCE 1 SOURCE 2 SOURCE Control PC ViewScape 1 ViewScape 2 Display Input 1 Input 2 Input 9 Input 8 Input 4 Input 12 Image 4 12 DX 700 and DX 100 The DX 700 and DX 100 is a multi window video processor designed for use as a versatile fro...

Страница 30: ...trol and configure the digitizer as well as the Barco LED wall via a PC e g Director toolset Minimum required software version 2 04 Image 4 13 Control software Director toolset CAUTION Refer to the manual s of the used control software for more information about installation and usage guidelines 26 R59770542 SF 10V DISPLAY 03 12 2010 ...

Страница 31: ...G Safety first Fence off the installation area before starting to install your SF 10V display En sure you read understand and follow all safety instructions mentioned in the chapter Safety page 3 of this installation manual Furthermore make sure that all installation requirements for your SF 10V display are fulfilled see chapter 3 Installation requirements Installation requirements page 11 Overvie...

Страница 32: ...on Screen supporting securing structures vary from system to system Consult Barco for advise on professional rigging organizations SF 10V mounting plates Barco provides mounting plates for the SF 10V tiles which can be used to mount the tiles to the support structure A B Image 5 1 A Middle mounting plate B Top Bottom mounting plate 28 R59770542 SF 10V DISPLAY 03 12 2010 ...

Страница 33: ...to the support structure Image 5 2 CAUTION The following procedure must be performed by minimum three authorized and qualified technical persons which are thoroughly familiar with the product and all of the proper safety checks of this product To do otherwise increases the risk of hazard and injury to the user SF 10V tile mounting sequence Build up the SF 10V display row by row from bottom to top ...

Страница 34: ...mounting plates and let the mounting plate attache to the support structure Caution Two persons are required at the front of the LED display to perform this action Both hands must be free to insert a tile in a LED wall Therefore the use of a ladder to insert a tile is forbidden Only a solid scaffold or a Z lift is allowed Tip Use the Pin hole on the top side to lift the SF 10V tile using a crane a...

Страница 35: ...just block in the top of tile for the height alignment Tip For maximum adjustment space in horizontal direction place the hex cap bolts of the very first SF 10V tile that is placed on the support structure in the middle of the corresponding slots 6 Fasten the SF 10V tile At least one person at the front keeps the SF 10V tile steady until the tile is completely fasten R59770542 SF 10V DISPLAY 03 12...

Страница 36: ... alignment between tiles Open the back door using the long allen key rotate the socket head screw that located the top of tile as illustrated If the allen key clockwise rotate the adjust block will go up if rotate counter clockwise the adjust block will go down 32 R59770542 SF 10V DISPLAY 03 12 2010 ...

Страница 37: ...5 Physical installation A B B Image 5 7 A Adjust block screw B Long allen key 14mm R59770542 SF 10V DISPLAY 03 12 2010 33 ...

Страница 38: ...5 Physical installation 34 R59770542 SF 10V DISPLAY 03 12 2010 ...

Страница 39: ...ONS About this chapter This chapter contains drawings of the SF 10V tiles and its package with the most important dimensions Overview SF 10V tile Assembly of SF 10V tiles SF 10V package R59770542 SF 10V DISPLAY 03 12 2010 35 ...

Страница 40: ...6 Dimensions 6 1 SF 10V tile Dimensions of the SF 10V tile 1280 mm 960 mm 910 mm 1200 mm 205mm 156mm M10 Image 6 1 36 R59770542 SF 10V DISPLAY 03 12 2010 ...

Страница 41: ...6 Dimensions 6 2 Assembly of SF 10V tiles Main dimensions of an a assembly of SF 10V tiles 910 mm 910 mm 50 910 mm 80 80 80 80 1200 mm 1200 mm 1200 mm 50 Image 6 2 R59770542 SF 10V DISPLAY 03 12 2010 37 ...

Страница 42: ...6 Dimensions 6 3 SF 10V package Dimensions of the SF 10V tile package containing 4 tiles 1364mm 1384mm 1424 mm 1041 mm 1156mm 115 mm 1092 mm 1032 mm Image 6 3 38 R59770542 SF 10V DISPLAY 03 12 2010 ...

Страница 43: ...7 Specification 7 SPECIFICATION R59770542 SF 10V DISPLAY 03 12 2010 39 ...

Страница 44: ...7 Specification 40 R59770542 SF 10V DISPLAY 03 12 2010 ...

Страница 45: ... 75 75 Horizontal Viewing Angle 50 brightness 55 55 Vertical Viewing Angle color shirt 40 30 Vertical Viewing Angle 50 brightness 23 20 Max Power consumption 1 066 W m Typical Power consumption Operation Power Voltage and frequency 110 240V 50 60Hz LED Lifetime 60 000 Environmental Operational Temperature 20 C 40 C 4 F to 104 F Storage Temperature 20 C 40 C 4 F to 104 F Start up temp 20 C to 40 C ...

Страница 46: ...o Yes DX 700 Yes DMP 100 No AEC 4000 in combination with DTS Yes AEC 4000 in combination with RMS No Fiberlink II Yes CAT5 Link Yes DTS Software Yes RMS Software No XVS Yes Certifications CE RohS ETL 42 R59770542 SF 10V DISPLAY 03 12 2010 ...

Страница 47: ... the order numbers of several important SF 10V peripherals Overview Order info Spare part and service kits Consult the secured partner zone on www Barco com for an updated list with order numbers of the available SF 10V products R59770542 SF 10V DISPLAY 03 12 2010 43 ...

Страница 48: ...431 FIBERLINK MULTIMODE CABLE 100M R9850432 FIBERLINK MULTIMODE CABLE 150M R9850433 FIBERLINK MULTIMODE CABLE 200M R9850434 FIBERLINK MULTIMODE CABLE 250M R9850435 FIBERLINK MULTIMODE CABLE 300M Z3472571 BME SF Series Spider Cable Same Length Z3472569 BME SF Series Spider Cable Diff Length R9851260 POWER VEAM CABLE 10M R9851261 POWER VEAM CABLE 20M R9851262 POWER VEAM CABLE 30M R9851263 POWER VEAM...

Страница 49: ...e future new kits can be added to this list Contact Barco to get an updated list Order info Description R9870040 SF 10V LED Frame Kit R9870043 SF 10V Shader Kit R9870049 SF Series Fan Kit R9870050 SF Series Power Supplier R9870052 SF 10V Data Cable Kit R9870055 SF 10V Power Cable Kit R9870057 SF Series tooling Kit R765866K SF 10 Ctr Board Kit R59770542 SF 10V DISPLAY 03 12 2010 45 ...

Отзывы: