4. Hardware orientation
3
Genlock BNC Input and Output
–
–
5
Expansion Links
–
–
7
Input cards (HDMI/DP, SDI, DVI)
8
Outputs cards (DVI, SDI)
8
Multiviewer card (HDMI)
–
–
10
USB 2.0 port
The EX image in image 4-7 is an example only. The EX expansion box does not ship with cards; cards must
be purchased separately.
Description
E2
E2 Jr.
S3–4K
S3–4K Jr.
EX
1
AC connectors
2
2
2
1
1
2
RJ-45 connector for 10/100 BaseT Ethernet
communications
1
1
1
1
1
3
Genlock Input BNC with passive Loop-through
2
2
2
2
NA
1
4
S3D In and S3D Out
4 In, 2 Out
4 In, 2 Out
4 In, 2 Out
4 In, 2 Out
NA
5
Expansion Link cards
2
NA
2
1
NA
2
NA
3
6
VPU cards
NA
NA
2
1
NA
7
Input cards (HDMI/DP, SDI, DVI)
8
4
3
2
≤
2
4
8
Outputs cards (DVI, SDI)
4
3
3
2
≤
2
4
9
Multiviewer card (HDMI)
1
1
1
1
≤
1
4
10 USB 2.0 port
NA
NA
NA
NA
1
Table 4-2
Comparison of Event Master rear-panel connections
1
The EX expansion box internally generates genlock output.
2
E2 Jr. and S3–4K Jr. do not have expansion Link cards.
3
The EX has two (2) Expansion Links integrated in the chassis.
4
Each EX expansion box has two general purpose card slots, each of which may support any E2 input or
output card.
AC connectors
Event Master E2, E2 J., S3–4K, and S3–4K Jr. series processors are equipped with two redundant power supplies. During normal
operation the load is shared equally by both supplies. If one supply fails, the second carries the whole load. Two AC Connector are
provided to connect Event Master series processors to your facility’s AC power source through the supplied power cords.
Input Power Speci
fi
cation: 100-240 VAC, 47-63 Hz
On each power supply there are 3 LED lights that provide status information as follows:
•
DC Output Power LED: when Green, the supply is outputting valid DC power.
•
Status LED: when amber indicates that an error has occurred.
•
AC Input Power LED: when green it indicates that the supply is connected to a valid AC power.
Therefore, during normal operating conditions, the input AC and Output DC LEDs will turn green.
Note that the power supplies are installed upside down in the E2 model, so the silkscreen markings will also ap-
pear upside down. Power supplies in the S3 model are installed in the correct orientation for reading silkscreen
markings.
Ethernet port
One RJ-45 connector is provided for 10/100BaseT Ethernet communications with the Event Master series processor. The port is
used for running the Web Interface and for connection to an external device.
The Ethernet connector is compatible with:
•
Standard RJ-45 Ethernet cables
•
Neutrik EtherCon® series cables
46
R5905948 EVENT MASTER DEVICES 17/07/2017
Содержание S3 series
Страница 1: ...Event Master Devices User s Guide R5905948 05 17 07 2017 ...
Страница 9: ...Table of contents Index 531 R5905948 EVENT MASTER DEVICES 17 07 2017 5 ...
Страница 10: ...Table of contents 6 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 20: ...2 Safety 16 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 66: ...4 Hardware orientation 62 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 90: ...5 Front Panel Menu orientation 86 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 264: ...8 Updating firmware 260 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 268: ...9 General operation example Image 9 3 264 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 285: ...9 General operation example Image 9 25 R5905948 EVENT MASTER DEVICES 17 07 2017 281 ...
Страница 288: ...9 General operation example 284 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 316: ...10 Controller orientation 312 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 326: ...11 Controller Configuration 322 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 352: ...12 Controller Operation 348 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 356: ...13 E2 Maintenance 13 2 Process Overview Flow chart Image 13 2 352 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 417: ...13 E2 Maintenance Disregard the heatsink from the spare kit R5905948 EVENT MASTER DEVICES 17 07 2017 413 ...
Страница 418: ...13 E2 Maintenance 414 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 422: ...14 S3 Maintenance 14 2 Process Overview Flow chart Image 14 2 418 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 488: ...16 EC 200 Maintenance 484 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 494: ...17 Environmental information 490 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 512: ...A Specifications 508 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 527: ...C Troubleshooting C TROUBLESHOOTING R5905948 EVENT MASTER DEVICES 17 07 2017 523 ...
Страница 528: ...C Troubleshooting 524 R5905948 EVENT MASTER DEVICES 17 07 2017 ...