2. Basic Commands
Data[1] = 0 : disable
Data[1] = 1 : enable
2.41.4
Blanking, Write
Description
Blanks the display.
Four blanking methods are possible:
•
Top
•
Bottom
•
Left
•
Right
The blanking may also be chosen to be performed on the display or on the image file (saved in the image file).
Command
Top blanking:
Command [0]
\x20
Command [1]
\x4c
Bottom blanking:
Command [0]
\x20
Command [1]
\x4d
Left blanking:
Command [0]
\x20
Command [1]
\x4e
Right blanking:
Command [0]
\x20
Command [1]
\x4f
Data
byTypeBlanking : one byte describing the type of blanking
Data [0] = 0 : blanking on image file (saved in image file)
Data [0] = 1 : blanking on display
Wvalue : Unsigned word (2 bytes) representing the number of pixels to be blanked.
Data [1] = msb
Data [2] = lsb
The maximum number of pixels which can be blanked depends on the native resolution of the panels
The panel size can be read using the Panel Size read command.