2. Basic Commands
2.41.1
Blanking Reset
Description
Allows the reset of the blanking values.
Command
Command [0]
\x17
Data
byTypeBlanking : 1 byte describing the type of blanking.
Data [0] = 0 : blanking done and saved in the image file
Data [0] = 1: blanking done on the display
The maximum number of pixels which can be blanked depends on the native resolution of the panels
2.41.2
Blanking enable, Write
Description
Enables the blanking.
Command
Command [0]
\x20
Command [1]
\x56
Data
Data[0] = byTypeBlanking
Data[0] = 0 : blanking on image file
Data[0] = 1: blanking on display
Data[1] = unsigned byte
Data[1] = 0 : disable
Data[1] = 1 : enable
2.41.3
Blanking enable, Read
Description
Reads whether the blanking is enabled.
Command
Command [0]
\x21
Command [1]
\x56
Sent Data
byTypeBlanking : one byte describing the type of blanking
Data [0] = 0 : blanking on image file (saved in image file)
Data [0] = 1 : blanking on display
Returned Data
Data[0] = byTypeBlanking
Data[0] = 0 : blanking on image file
Data[0] = 1: blanking on display
Data[1] = unsigned byte
80