7. ICMP
7.6
ICMP HDD status LEDs
ICMP HDD status LEDs
5
4
Image 7-8
Status overview PWR/ERROR and READY LEDs:
4
5
HDD I/O
RAID
ICMP HDD Status
Off
Off
HDD idle / Disk in RAID OK.
Blinking Green
Off
HDD I/O activity / Disk in RAID OK.
Blinking Green
Blinking Red
HDD I/O activity / RAID rebuilding.
Off
Red
HDD idle / Disk error. See troubleshooting table below for curative actions.
Troubleshooting
Situation
Solution
One disk failed (red LED) +
RAID degraded
.
The ongoing event is not interrupted.
Note:
The disk status (RAID degraded) can be retrieved via the
(Web) Commander. See user guide of the (Web) Commander.
Hot swap the defect HDD with an original HDD spare part. No
need to switch off the power. Ensure to insert the HDD
fi
rmly.
See procedure "Installing a HDD into the ICMP", page 118.
Result:
As soon the new HDD is detected by the ICMP the
rebuild of the RAID is started (Blinking red LED).
One disk failed (red LED) + Error 10580 “
local storage not
available
”.
Note:
The disk status (Error code) can be retrieved via the
(Web) Commander. See user guide of the (Web) Commander.
1.
Switch off the power.
2.
Replace the defect HDD with an original HDD spare part.
See procedure "Removing a HDD form the ICMP", page
117, and "Installing a HDD into the ICMP", page 118.
Ensure to insert the HDD
fi
rmly.
3.
Switch on the power.
Result:
As soon the new HDD is detected by the ICMP the
rebuild of the RAID is started (Blinking red LED).
Multiple disks failed (multiple red LEDs) +
RAID broken
.
Note:
The disk status (RAID broken) can be retrieved via the
(Web) Commander. See user guide of the (Web) Commander.
1.
Switch off the power.
2.
Replace all defect HDDs with original HDD spare parts.
See procedure "Removing a HDD form the ICMP", page
117, and "Installing a HDD into the ICMP", page 118.
Ensure to insert the HDDs
fi
rmly.
3.
Switch on the power.
4.
Start “RAID Initialize”. See user guide of the
Communicator.
Result:
a new empty RAID is created.
All HDD LEDs remain off + Error 10580 “
local storage not
available
”.
Note:
The disk status (Error code) can be retrieved via the
(Web) Commander. See user guide of the (Web) Commander.
1.
Switch off the power.
2.
Reseat all HDDs. See procedure "Removing a HDD
form the ICMP", page 117, and "Installing a HDD into the
ICMP", page 118. Ensure to insert the HDDs
fi
rmly.
3.
If problem remains try “RAID Initialize”. See user guide of
the Communicator. Note that all content will be lost!
4.
If problem remains contact Service for further instructions.
114
R5905963 PROMETHEUS SERIES 09/03/2015
Содержание Prometheus I
Страница 1: ...Prometheus series Installation safety manual R5905963 00 09 03 2015 ...
Страница 15: ...1 Safety PR Image 1 2 R5905963 PROMETHEUS SERIES 09 03 2015 11 ...
Страница 92: ...5 Lenses lens holder 88 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Страница 124: ...7 ICMP 120 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Страница 130: ...8 Communicator Touch Panel 126 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Страница 134: ...9 Starting up 130 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Страница 144: ...10 Removal and installation of the projector covers Image 10 12 Side cover 140 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Страница 152: ...10 Removal and installation of the projector covers 148 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Страница 176: ...13 Specifications 172 R5905963 PROMETHEUS SERIES 09 03 2015 ...