8. Cabling of an OLite rental display
W
ARNING
:
To protect against risk of fire by overloading of power cables, the amount of OLite tiles per power
source cable is limited. Never connect more than 2 OLite tiles with a power source cable.
Necessary parts
•
Power box(es) with matching cables.
•
Power linking cables.
•
Dummy power plugs
How to realize the power cabling of an OLite rental display ?
1. Install the power box nearby the OLite rental display. Ensure the power box provides as much power circuits as required to
energize the display in a safe manner. If necessary, install several power boxes. See manual of the used power box for installation
instructions.
2. Connect a power source cable coming from the power box with the lower tile in a column of two high.
Note:
Depending on the type of used power box, a multi power cable in combination with a spider connector is inserted between
the power box and the power source cable leading to the OLite tile. See manual of the used power box to realize the
cabling between power box and OLite display.
3. Place a power linking cable between the tile, receiving power directly from the power box via a power source cable, and the tile
above.
4. Place a dummy power plug on the power output socket of the upper tile in the power branch.
5. Make sure that all plug holder clamps are locked firmly.
6. Repeat from step 2 until all OLite rental tiles are provided with power.
Example of power cabling
The example below shows the power cabling of a two by two OLite rental display. The rental power box is connected via a multi
power cable with a spider connector. Each spider output cable leads to a column of two OLite tiles. The power connection in this
column is realized with a power linking cable. Note that the unused power output socket is sealed with a dummy power plug.
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
POWER
DATA
OUT
IN
A
B
C
D
E
Image 8-2
A
Power box.
B
Multi power cable.
C Spider connector.
D Power linking cable.
E
Dummy power plug.
44
R5976832 OLITE RENTAL DISPLAY 15/12/2004
Содержание OLite 510
Страница 1: ...OLite rental display Installation manual R5976832 00 15 12 2004...
Страница 4: ......
Страница 10: ...1 Safety 6 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Страница 12: ...2 Installation requirements 8 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Страница 14: ...3 System overview 10 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Страница 22: ...4 Components of an OLite rental tile 18 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Страница 46: ...7 Basic set up procedures 42 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Страница 52: ...8 Cabling of an OLite rental display 48 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Страница 54: ...9 Maintenance 50 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Страница 64: ...A Dimensions 60 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Страница 70: ...C Order info 66 R5976832 OLITE RENTAL DISPLAY 15 12 2004...