R5913350 /05
Nio Fusion 12MP
32
4.12 Viewing modes
About viewing modes
The Nio Fusion 12MP can be used in 2 viewing modes:
•
Diagnostic:
This mode provides the full calibrated luminance and is intended for using the display for
diagnostic purposes.
•
Text:
In this mode, the luminance is reduced to approximately half of the luminance. This is intended for
using the display with office applications such as word processing.
Please note that text mode is not persistent, once powered off, the unit will restart in diagnostic mode.
The diagnostic mode should always be selected when the Nio Fusion 12MP is intended to be used
in a diagnostic environment.
To select a viewing mode:
1.
Bring up the OSD main menu.
2.
Navigate to the
Configuration > Calibration
menu.
3.
Enter the
Viewing Mode
submenu.
4.
Select
Diagnostic/Text
as desired and confirm.
4.13 Display functions
About display functions
Native, uncorrected panels will display all grayscale/color levels with luminance increments that are not
optimal for crucial diagnostic information. Studies have shown however, that in medical images certain
grayscale/color parts contain more diagnostic information then others. To respond to these conclusions,
display functions have been defined. These functions emphasize on these parts containing crucial diagnostic
information by correcting the native panel behavior.
The available display functions for your display are:
•
Native:
The native display panel behavior will not be corrected.
•
Dynamic Gamma 1.8
or
2.2
: These are gamma functions that are shifted to take into account the non-zero
luminance of an LCD panel when driven with a “black” signal. They are especially useful in CT applications
to improve the perception of low Hounsfield values.
•
DICOM:
DICOM (Digital Imaging and Communications in Medicine) is an international standard that was
developed to improve the quality and communication of digital images in radiology. In short, the DICOM
display function results in more visible grayscales in the images. Barco recommends selecting the DICOM
display function for most medical viewing applications.
•
sRGB:
The sRGB color space combines a display function, color space and white point selection, and is
designed to match typical home and office viewing conditions. It is widely used in most computer
applications.
Note:
This setting does not fully set your display to the sRGB color space. Refer to
to do this.
•
User:
This display function will be automatically selected when display functions are defined by QAWeb.
•
Gamma 1.8
or
2.2
: Select one of these display functions in case the display is to replace a CRT display
with a gamma of 1.8 or 2.2 respectively.
•
Test:
For Barco service purposes only.
The settings of the display must be adapted to suit the requirements of the visualization software. In
case of doubt, please contact the vendor of the visualization software.
To select a display function:
1.
Bring up the OSD main menu.
2.
Navigate to the
Configuration > Calibration
menu.
Содержание Nio Fusion 12MP
Страница 1: ...ENABLING BRIGHT OUTCOMES MDNC 12130 User guide Nio Fusion 12MP...
Страница 10: ...R5913350 05 Nio Fusion 12MP 10 Welcome...
Страница 20: ...R5913350 05 Nio Fusion 12MP 20 Installation and setup...
Страница 26: ...R5913350 05 Nio Fusion 12MP 26 Advanced operation...
Страница 42: ...R5913350 05 Nio Fusion 12MP 42 Advanced operation...
Страница 43: ...43 R5913350 05 Nio Fusion 12MP Cleaning the display 5...
Страница 45: ...45 R5913350 05 Nio Fusion 12MP Repackaging instructions 6...
Страница 49: ...49 R5913350 05 Nio Fusion 12MP Image 6 7 Repackaging instructions...
Страница 50: ...R5913350 05 Nio Fusion 12MP 50 Repackaging instructions...
Страница 68: ...R5913350 05 Nio Fusion 12MP 68 Important information...
Страница 69: ......
Страница 70: ...www barco com R5913350 05 2022 12 19 Barco NV President Kennedypark 35 8500 Kortrijk Belgium...