3. Operation

3. OPERATION

3.1

Recommendations for daily operation

Optimize the lifetime of your display

Enabling the Display Power Management System (DPMS) of your display will optimize its lifetime by auto-
matically switching off the backlight when the display is not used for a speci

fi

ed period of time. By default,

DPMS is enabled on your display, but it also needs to be activated on your workstation. To do this, go to
“Power Options Properties” in the “Control Panel”.

Barco recommends setting DPMS activation after 20 minutes of non-usage.

Use a screen saver to avoid image retention

Prolonged operation of an LCD with the same content on the same screen area may result in a form of
image retention.

You can avoid or signi

fi

cantly reduce the occurrence of this phenomenon by using a screen saver. You

can activate a screen saver in the “Display properties” window of your workstation.

Barco recommends setting screen saver activation after 5 minutes of non-usage. A
good screen saver displays moving content.

In case you are working with the same image or an application with static image elements for several hours
continuously (so that the screen saver is not activated), change the image content regularly to avoid image
retention of the static elements.

Understand pixel technology

LCD displays use technology based on pixels. As a normal tolerance in the manufacturing of the LCD, a
limited number of these pixels may remain either dark or permanently lit, without affecting the performance
of the product. To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels.

To learn more about LCD technology and missing pixels, consult the dedicated white
papers available at

www.barco.com/healthcare

.

Maximize quality assurance

QAWeb guarantees optimum and stabilized image quality in every private practice.

The front sensor on the Nio Color 2MP 23" works seamlessly with QAWeb to ensure a consistent image
over time. It automatically stabilizes the image from the moment you switch on the display. What’s more,
QAWeb provides you with instant feedback on the status of the display.

K5902134 NIO COLOR 2MP 23" 05/07/2017

13

Содержание Nio Color 2MP

Страница 1: ...Nio Color 2MP 23 User Guide MDNC 2123 option DE K5902134 01 05 07 2017...

Страница 2: ...26 22 62 Support www barco com en support Visit us at the web www barco com Registered address Barco NV President Kennedypark 35 8500 Kortrijk Belgium Phone 32 56 23 32 11 Fax 32 56 26 22 62 Support w...

Страница 3: ...4 3 5 Input source selection 14 3 6 Luminance adjustment 15 3 7 sRGB color space 15 3 8 Display functions 15 3 9 White point selection 16 3 10 Power save mode 16 3 11 OSD menu language 17 3 12 Factory...

Страница 4: ...Table of contents 2 K5902134 NIO COLOR 2MP 23 05 07 2017...

Страница 5: ...dard because of Barco s luminance sensor technology and MediCal QAWeb software By constantly measuring and monitoring display brightness we can ensure that your dental images will look consistent and...

Страница 6: ...uide 1x system disc 1x documentation disc 1x video signal cable 1x USB cable 1x set of AC power cords depending on the region of operation Keep your original packaging It is designed for this display...

Страница 7: ...oll up in the OSD menu o to increase values in the OSD menu Turn left o to scroll down in the OSD menu o to decrease values in the OSD menu 4 Front sensor 5 Ambient light sensor 6 Power status LED Off...

Страница 8: ...SB B 2 0 upstream connector 3 USB A 2 0 downstream connectors 2x 4 DisplayPort video input 5 Earth pin 6 DVI D video input 7 100 240 VAC mains power input IEC C14 8 VESA 100 mm mounting screw holes 4x...

Страница 9: ...on CAUTION When the display is assembled in the medical system take care of the fixa tion of all cables to avoid unwanted detachment CAUTION The monitor is not intended to be sterilized 2 1 Stand base...

Страница 10: ...iate video cable s to do this The input source to be displayed can be selected in the OSD menus see Input source selection page 14 Image 2 3 2 Connect the USB upstream connector to a PC USB host to ma...

Страница 11: ...rounded outlet by means of a yellow green AWG18 wire maximum admitted cable length according to national regulation requirements Image 2 6 5 Route all cables through the provided cable routing clip at...

Страница 12: ...de is functionally not supported 2 4 VESA mount installation To mount the display on a VESA arm The display panel standard attached to the stand is compatible with the VESA 100 mm standard 1 Unscrew t...

Страница 13: ...4 M4 screws to attach the panel to a VESA approved arm Please respect the following rule to select an appropriate screw length Lmin T W 6 mm Lmax T W 14 mm T W Lmin Lmax Image 2 9 K5902134 NIO COLOR...

Страница 14: ...2 Installation 12 K5902134 NIO COLOR 2MP 23 05 07 2017...

Страница 15: ...n saver displays moving content In case you are working with the same image or an application with static image elements for several hours continuously so that the screen saver is not activated change...

Страница 16: ...submenu or confirm adjustments and selections 3 4 OSD menu locking unlocking About To avoid unwanted or accidental activation of the OSD menu a lock mechanism can be enabled This mechanism will automa...

Страница 17: ...parts contain more diagnostic information then others To respond to these conclusions display functions have been defined These functions emphasize on these parts containing crucial diag nostic infor...

Страница 18: ...About white point selection This setting allows you to modify the display white point used as reference for all other colors to be dis played The available white point settings for your display are Na...

Страница 19: ...SD main menu 2 Navigate to the Adjustments Settings menu 3 Enter the OSD Language submenu 4 Select one of the available languages 3 12 Factory reset About factory reset A factory reset allows you to f...

Страница 20: ...3 Operation 18 K5902134 NIO COLOR 2MP 23 05 07 2017...

Страница 21: ...ply excessive pressure on the front glass or LCD CAUTION Do not apply or spray liquid directly to the display as excess liquid may cause damage to internal electronics Instead apply the liquid to a cl...

Страница 22: ...70 Strong alkalis lye strong solvents Acid Detergents with fluoride Detergents with ammonia at higher concentration 1 6 Detergents with abrasives Steel wool Sponge with abrasives Steel blades Cloth wi...

Страница 23: ...xygen or nitrous oxide Non patient care equipment Equipment primarily for use in a health care facility that is intended for use where contact with a patient is unlikely no applied part The equipment...

Страница 24: ...he safety standard of your particular country Water and moisture Never expose the display to rain or moisture Never use the display near water e g near a bathtub washbasin swimming pool kitchen sink l...

Страница 25: ...te disposal service For details please visit the Barco website at http www barco com en AboutBarco weee Turkey RoHS compliance T rkiye Cumhuriyeti AEEE Y netmeli ine Uygundur Republic of Turkey In con...

Страница 26: ...cts EIP that are sold within Chinese Mainland must comply with the Marking for the restriction of the use of hazardous substances in electrical and electronic product of Chi nese Mainland marked with...

Страница 27: ...e must accept any interference re ceived including interference that may cause undesired operation This device has been tested and found to comply with the limits for a Class B digital device pursuant...

Страница 28: ...on If this equipment does cause harmful interference to or suffer from harmful interference of surrounding equipment the user is encouraged to try to correct the interference by one or more of the fo...

Страница 29: ...cy magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3 Vrms 150 kHz to 80 MH...

Страница 30: ...P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies 3 Field strengths from fixed tra...

Страница 31: ...Canada and US Indicates the device is approved according to the UL regulations for Canada and US Indicates the device is approved according to the UL Demko regulations Indicates the device is approve...

Страница 32: ...number or catalogue number Warning dangerous voltage Caution Consult the operating instructions Indicates this device must not be thrown in the trash but must be recycled according to the European WE...

Страница 33: ...heric pressure to which the medical device can be safely exposed when being stored 5 7 Legal disclaimer Disclaimer notice Although every attempt has been made to achieve technical accuracy in this doc...

Страница 34: ...ls Pixel pitch 0 2715 mm Color imaging Yes Gray imaging Yes Bit depth 30 bit Viewing angle H V 178 Ambient light presets Yes reading room selection Ambient light sensor Yes Front sensor Yes Maximum lu...

Страница 35: ...eflective glass cover Option DE WH N A Recommended modalities All digital images except digital mammography Certifications CE0120 MDD 93 42 EEC A1 2007 47 EC class IIb product CE 2014 30 EU IEC 60950...

Страница 36: ...arco Terms Conditions for specific Warranty conditions Operating temperature 0 C to 40 C 15 C to 35 C within specs Storage temperature 20 C to 60 C Operating humidity 8 to 80 non condensing Storage hu...

Отзывы: