Moisture condensation
•
Do not use monitor under rapid temperature and humidity change condition or avoid cold air from air-
conditioning outlet directly.
•
Moisture may condense on the surface or inside of the unit, or create a mist residue inside the protection
plate, this is not a malfunction of the product itself, although it may cause damage to the monitor.
•
If condensation happens, let the monitor stand unplugged until there is no condensation.
Ventilation
Do not cover or block any ventilation openings in the cover of the set. When installing the device in a cupboard
or another enclosed location, heed the necessary space between the set and the sides of the cupboard.
Installation
•
Place the equipment on a flat, solid and stable surface that can support the weight of at least 3 devices. If
you use an unstable cart or stand, the equipment may fall, causing serious injury to a child or adult, and
serious damage to the equipment.
•
Do not allow to climb or rest on the equipment.
•
The monitor has been designed to be used in landscape position with a tilt of -10° (backward) and +10°
(forward)
•
When adjusting the angle of the equipment, move it slowly so as to prevent the equipment from moving or
slipping off from its stand or arm.
•
When the equipment is attached to an arm, do not use the equipment as a handle or grip in order to move
the equipment. Please refer to the instruction manual of the arm for instructions on how to move the arm
with the equipment.
•
Provide full attention to safety during installation, periodic maintenance and examination of this equipment.
•
Sufficient expertise is required for installing this equipment, especially to determine the strength of the wall
for withstanding the display's weight. Be sure to entrust the attachment of this equipment to the wall to
licensed contractors of Barco and pay adequate attention to safety during the installation and usage.
•
All devices and complete setup must be tested and validated before taking into operation.
•
At end user application level it is necessary to foresee a backup unit in case the video falls away.
•
Barco is not liable for any damage or injury caused by mishandling or improper installation.
Malfunctions
Disconnect the equipment’s power cord from the AC inlet and refer servicing to qualified service technicians
under the following conditions:
•
If the power cord or plug is damaged or frayed.
•
If liquid has been spilled into the equipment.
•
If the equipment has been exposed to rain or water.
•
If the equipment does not operate normally when the operating instructions are followed. Adjust only those
controls that are covered by the operating instructions since improper adjustment of other controls may
result in damage and will often require extensive work by a qualified technician to restore the product to
normal operation.
•
If the equipment has been dropped or the cabinet has been damaged.
•
If the product exhibits a distinct change in performance, indicating a need for service.
General warnings
•
The device has no means to be incorporated in an IT-network in the clinical environment.
•
The enclosure has to be checked upon collision damage, refer to qualified service personnel.
•
The protective screen (if present) is made of tested high-resistance glass. Nonetheless there is the
possibility that it may crack if subject to strong impacts. Evaluate and prevent the risk of possible
breakages of the protective screen by correctly handling and positioning the monitor in the operating room.
•
The monitor is intended for indoor use
•
The monitor is not intended to be sterilized
•
The monitor has not applied parts, but the front side of the LCD panel and the plastic enclosure have been
treated as applied part because considered accidentally touchable by the patient for a time <1 minute.
Содержание MDSC-8532
Страница 6: ...R5914105 01 MDSC 8532 6 Welcome ...
Страница 12: ...R5914105 01 MDSC 8532 12 Welcome ...
Страница 13: ...13 R5914105 01 MDSC 8532 Display installation 2 ...
Страница 19: ...19 R5914105 01 MDSC 8532 Daily operation 3 ...
Страница 39: ...39 R5914105 01 MDSC 8532 Troubleshooting 5 ...
Страница 41: ...41 R5914105 01 MDSC 8532 Important information 6 ...
Страница 62: ...R5914105 01 MDSC 8532 62 Important information ...
Страница 63: ......
Страница 64: ...www barco com R5914105 01 2022 03 17 Barco NV President Kennedypark 35 8500 Kortrijk Belgium ...