manualshive.com logo in svg
background image

5. Important information

When the equipment is attached to an arm, do not use the equipment as a handle or grip in order to move
the equipment. Please refer to the instruction manual of the arm for instructions on how to move the arm
with the equipment.

Malfunctions

Disconnect the equipment’s power cord from the AC inlet and refer servicing to quali

fi

ed service techni-

cians under the following conditions:

If the power cord or plug is damaged or frayed.

If liquid has been spilled into the equipment.

If the equipment has been exposed to rain or water.

If the equipment does not operate normally when the operating instructions are followed. Adjust only
those controls that are covered by the operating instructions since improper adjustment of other con-
trols may result in damage and will often require extensive work by a quali

fi

ed technician to restore

the product to normal operation.

If the equipment has been dropped or the cabinet has been damaged.

If the product exhibits a distinct change in performance, indicating a need for service.

General warnings

All devices and complete setup must be tested and validated before taking into operation.

At end user application level it is necessary to foresee a backup unit in case the video falls away.

National Scandinavian Deviations for CL. 1.7.2

Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan"

Norway: "Apparatet må tilkoples jordet stikkontakt"

Sweden: "Apparaten skall anslutas till jordat uttag"

C

AUTION

:

The enclosure has to be checked upon collision damage, refer to quali

fi

ed

service personnel.

5.2

Environmental information

Disposal Information

Waste Electrical and Electronic Equipment

This symbol on the product indicates that, under the European Directive 2012/19/EU governing

waste from electrical and electronic equipment, this product must not be disposed of with other municipal
waste. Please dispose of your waste equipment by handing it over to a designated collection point for the
recycling of waste electrical and electronic equipment. To prevent possible harm to the environment or
human health from uncontrolled waste disposal, please separate these items from other types of waste
and recycle them responsibly to promote the sustainable reuse of material resources.

For more information about recycling of this product, please contact your local city of

fi

ce or your municipal

waste disposal service.

For details, please visit the Barco website at:

http://www.barco.com/en/AboutBarco/weee

K5902137 (451920612603) MDRC-1219 23/02/2018

25

Содержание MDRC-1219 HB

Страница 1: ...MDRC 1219 User Guide 19 1MP Multi Touch Color LCD Display MDRC 1219 MDRC 1219 TS MDRC 1219 HB MDRC 1219 HB TS K5902137 451920612603 02 23 02 2018...

Страница 2: ...26 22 62 Support www barco com en support Visit us at the web www barco com Registered address Barco NV President Kennedypark 35 8500 Kortrijk Belgium Phone 32 56 23 32 11 Fax 32 56 26 22 62 Support w...

Страница 3: ...t 15 3 8 sRGB color space 15 3 9 QAWeb presets 16 3 10 Display functions 16 3 11 White point selection 17 3 12 Analog video settings 17 3 13 Power save mode 18 3 14 OSD menu language 18 3 15 OSD menu...

Страница 4: ...Table of contents 2 K5902137 451920612603 MDRC 1219 23 02 2018...

Страница 5: ...s of precautionary or advisory statements that may be used in this user guide In descending order of importance they are WARNING Describes hazards or dangers that might result in personal injury or de...

Страница 6: ...signed for this display and is the ideal protection during transport and storage 1 2 Product overview Front 1 3 4 2 Image 1 1 MDRC 1219 and MDRC 1219 TS 1 4 2 Image 1 2 MDRC 1219 HB and MDRC 1219 HB T...

Страница 7: ...er clockwise o to scroll up in the OSD menu o to decrease values in the OSD menu 3 Front sensor only for MDRC 1219 and MDRC 1219 TS 4 Power status LED Off Display not powered or display is on but powe...

Страница 8: ...0 upstream connector 3 USB A 2 0 downstream connectors 2x for MDRC 1219 and MDRC 1219 TS 4 DisplayPort video input 5 Earth pin 6 DVI I video input 7 100 240 VAC mains power input IEC C14 8 Height adju...

Страница 9: ...AUTION When the display is assembled in the medical system take care of the fixa tion of all cables to avoid unwanted detachment CAUTION The monitor is not intended to be sterilized 2 1 Cable connecti...

Страница 10: ...ost to make use of QAWeb or any of the display USB downstream connectors e g to connect a keyboard mouse or other peripheral Image 2 3 MDRC 1219 and MDRC 1219 TS Image 2 4 MDRC 1219 HB and MDRC 1219 H...

Страница 11: ...G18 wire maximum admitted cable length according to national regulation requirements Image 2 7 MDRC 1219 and MDRC 1219 TS Image 2 8 MDRC 1219 HB and MDRC 1219 HB TS 5 Route all cables through the prov...

Страница 12: ...t is landscape If you use the display in portrait mode make sure you change the orientation of the video input via the screen settings of the computer 2 3 VESA mount installation To mount the display...

Страница 13: ...panel from the stand Image 2 10 2 Use 4 M4 screws to attach the panel to a VESA approved arm Please respect the following rule to select an appropriate screw length Lmin T W 8 mm Lmax T W 14 mm T W Lm...

Страница 14: ...2 Installation 12 K5902137 451920612603 MDRC 1219 23 02 2018...

Страница 15: ...n saver displays moving content In case you are working with the same image or an application with static image elements for several hours continuously so that the screen saver is not activated change...

Страница 16: ...l to go into a submenu or confirm adjustments and selections 3 4 Power status LED Overview The power status of the display is indicated by a LED at the front of the display Below is an overview of the...

Страница 17: ...OSD main menu 2 Navigate to the Input selection menu 3 Select one of the available input sources and confirm 3 7 Luminance adjustment To adjust the luminance 1 Bring up the OSD main menu 2 Navigate t...

Страница 18: ...ined These functions emphasize on these parts containing crucial diag nostic information by correcting the native panel behavior The available display functions for your MDRC 1219 are Native If you se...

Страница 19: ...lm color temperature Clearbase Simulation of the clearbase film color temperature Programmable When selecting this setting you will be able to manually adjust the video gain for the red green and blue...

Страница 20: ...14 OSD menu language About the OSD menu language By default the OSD menu comes up in English However there s a wide range of other languages avail able for the OSD menu of your MDRC 1219 To select th...

Страница 21: ...r the Factory Reset submenu 4 Select Yes or No as desired and confirm 3 17 Touchscreen About touchscreen This is only applicable for the MDRC 1219 TS and MDRC 1219 HB TS options Touchscreen is interfa...

Страница 22: ...3 Operation 20 K5902137 451920612603 MDRC 1219 23 02 2018...

Страница 23: ...essive pressure on the front glass or LCD CAUTION Do not apply or spray liquid directly to the display as excess liquid may cause damage to internal electronics Instead apply the liquid to a cleaning...

Страница 24: ...Strong alkalis lye strong solvents Acid Detergents with fluoride Detergents with ammonia at higher concentration 1 6 Detergents with abrasives Steel wool Sponge with abrasives Steel blades Cloth with...

Страница 25: ...xide The equipment shall not be operable when the air oxygen content is above 25 Non patient care equipment Equipment primarily for use in a health care facility that is intended for use where contact...

Страница 26: ...which has been approved and complies with the safety standard of your particular country Grounding reliability Grounding reliability can only be achieved when the equipment is connected to an equival...

Страница 27: ...application level it is necessary to foresee a backup unit in case the video falls away National Scandinavian Deviations for CL 1 7 2 Finland Laite on liitett v suojamaadoituskoskettimilla varustettuu...

Страница 28: ...dous substances that Barco s product may contain The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China in the section Limit Requirements of toxi...

Страница 29: ...cture and the specifications of this device as well as the materials used for manufacturing makes it easy to wipe and clean and therefore suitable to be used for various applications in hospitals and...

Страница 30: ...ay cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radi...

Страница 31: ...relocate the receiving antenna or equipment Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is c...

Страница 32: ...hould be at levels characteristic of a typical location in a typical commercial or hospital environment Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3 V m 150 kHz to 80 MHz 9 to 28 V m in comm...

Страница 33: ...1 2 P 80MHz to 800MHz d 1 2 P 800MHz to 2 5GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 2 Field strengths from fixed transmitters such as base stations for radio cellular cordless...

Страница 34: ...er supply you may find the following symbols nonrestrictive list Indicates the device meets the requirements of the applicable EC directives Indicates compliance with Part 15 of the FCC rules Class A...

Страница 35: ...ndicates the temperature limitations5 for the device to safely operate within specs Indicates the device serial number Indicates the device part number or catalogue number Warning dangerous voltage Ca...

Страница 36: ...tical boxes which may be stacked on each other where n is the limiting number xx yy Kg or xx yy xx yy Indicates the weight of the box and that it should be carried with two persons Indicates that the...

Страница 37: ...ocument is copyrighted All rights are reserved Neither this document nor any part of it may be reproduced or copied in any form or by any means graphical electronic or mechanical including photocopyin...

Страница 38: ...W x H x D 426 x 592 x 326 mm Net weight with stand 5 3 kg Net weight w o stand 3 1 kg Net weight packaged 8 1 kg Tilt 5 to 22 Pivot 90 Height adjustment range 110 mm Mounting standard VESA 100 mm Rec...

Страница 39: ...g angle H V 178 Ambient light presets Yes reading room selection Front sensor Yes Front Consistency Sensor Maximum luminance panel typical 330 cd m DICOM calibrated luminance 250 cd m Contrast ratio p...

Страница 40: ...CSA C22 2 No 60601 1 14 IEC 60529 1991 A1 2000 Degrees of protection IP code IEC 60601 1 2 2014 FCC class B ICES 001 Level B CCC GB9254 2008 GB4943 1 2011 GB17625 1 2012 VCCI KC Supplied accessories...

Страница 41: ...yPort USB ports 1x USB 2 0 upstream endpoint 1x USB 2 0 downstream Power requirements Internal power supply 100 240 Vac 50 60 Hz Power consumption 20 W nominal 0 5 W standby OSD languages English Germ...

Страница 42: ...0 C Operating humidity 20 to 80 non condensing Storage humidity 10 to 90 non condensing Operating pressure 70 kPa minimum Storage pressure 50 to 106 kPa MDRC 1219 HB TS Screen technology AHVA TFT Colo...

Страница 43: ...408 518 x 201 mm Dimensions w o stand W x H x D 411 x 348 x 67 mm Dimensions packaged W x H x D 426 x 592 x 326 mm Net weight with stand 6 2 kg Net weight w o stand 4 kg Net weight packaged 8 2 kg Til...

Страница 44: ...rs Operating temperature 0 C to 40 C Storage temperature 20 C to 60 C Operating humidity 20 to 80 non condensing Storage humidity 10 to 90 non condensing Operating pressure 70 kPa minimum Storage pres...

Отзывы: