background image

Encore Presentation System Router Support                                           

    Rev 03 

 

- 5 - 

 
 

 

PureLink PM Series

 

o

 

Select the PureLink-2 protocol for the Manufacturer in the router setup 
menu. 

o

 

Supports both Ethernet and RS-232 communications. 

o

 

Router’s factory reset default IP is 192.168.0.2, which conflicts with SP2 
Controller. Thus, set it to a unique IP or to the default IP suggested by the 
controller. Consult the PureLink users guide for help on setting up the 
router’s IP address. 

o

 

IP port is fixed at 23. 

o

 

Only one TCP/IP session is possible with the router. If router is currently 
connected with an Encore family controller, you will not be able to open a 
telnet session via your PC (or vice versa). 

o

 

Serial communication requires a straight-through cable between the router 
and the EXT COMM port on the controller. However, if you’re 
troubleshooting using a serial port from a PC, you’ll need a NULL modem 
cable/adapter. 

o

 

Serial port default settings: 19200 baud, 8 data bits, no parity, 1 stop bit, 
and no flow control. 

o

 

If the router ID is changed from the router 

after

 connection has been 

established with the controller, you will need to re-establish the 
connection again in order for the new ID to be read by the controller. 

o

 

Support for this router was tested on a PM Series – 32x32 HDMI, DVI, 
3G-SDI unit, running firmware 2.20. 