Encore Presentation System Router Support
Rev 03
- 5 -
PureLink PM Series
o
Select the PureLink-2 protocol for the Manufacturer in the router setup
menu.
o
Supports both Ethernet and RS-232 communications.
o
Router’s factory reset default IP is 192.168.0.2, which conflicts with SP2
Controller. Thus, set it to a unique IP or to the default IP suggested by the
controller. Consult the PureLink users guide for help on setting up the
router’s IP address.
o
IP port is fixed at 23.
o
Only one TCP/IP session is possible with the router. If router is currently
connected with an Encore family controller, you will not be able to open a
telnet session via your PC (or vice versa).
o
Serial communication requires a straight-through cable between the router
and the EXT COMM port on the controller. However, if you’re
troubleshooting using a serial port from a PC, you’ll need a NULL modem
cable/adapter.
o
Serial port default settings: 19200 baud, 8 data bits, no parity, 1 stop bit,
and no flow control.
o
If the router ID is changed from the router
after
connection has been
established with the controller, you will need to re-establish the
connection again in order for the new ID to be read by the controller.
o
Support for this router was tested on a PM Series – 32x32 HDMI, DVI,
3G-SDI unit, running firmware 2.20.