Encore Presentation System Router Support
Rev 03
- 4 -
device is connected to the Encore network, before applying Power to the
Lantronix device. This will ensure that the Lantronix device will get a
192.168.0.xxx address from the Controller since the Controller is a DHCP
server. If the Lantronix device does not see a DHCP server within 10
seconds, it will automatically assign itself a 169.xxx.xxx.xxx address
which is not compatible with the Controller address scheme.
o
Refer to the Lantronix documentation concerning the disabling of
"AUTO IP" mode if you want to set a static IP address on the Lantronix
device.
Leitch routers
o
When the Encore Controller connects to a Leitch Router via Ethernet, a
Telnet session is established between the Controller and the Router. As
part of establishing this connection, the router requires a User Name and
Password to be entered. The Controller does this automatically when
attempting to connect to the router by using the default factory account.
To ensure that a connection is successful, verify that the Leitch Router
has the following User Name and Password account.
User Name: leitch
Password: leitchadmin
Refer to the router "Installation, Configuration, and Operation Manual" for
more information on how to create user accounts.
o
For SERIAL connections use a straight serial cable between the Leitch
Router and the EXT COMM port on the controller
LightWare routers
o
Select the Extron Protocol
Nevion SDI routers
(Ethernet only)
o
IP port number: 4381
Nvision SDI routers
(Ethernet only)
o
IP port number: 5194 or 9193 (Nvision 9000)
Opticis DVI routers
(Ethernet only)
o
Router support confirmed on the ODM88 using Software Release
100917K. Contact Opticis for information on how to obtain software
upgrades for the ODM series of routers.
o
IP port number: 23
Purelink DS-1818M II DVI routers
o
Select "DPI/PureLink" for the Manufacturer in the router setup menu.
Sierra routers
o
IP port number: 10001