5. Troubleshooting
Code 8130: “Vertical lens shift stopped” (Warning)
Situation
Solution
Motor Control Board not calibrated.
Calibrate the Motor Control Board. See "Calibrate Motor Control Board", page 286.
Vertical shift motor disconnected.
Check if the wire unit of the vertical shift motor is connected with the motor.
Malfunction vertical shift motor.
Replace the vertical shift motor. See "Replacement of the Vertical Shift stepper motor",
page 234.
Code 8131: “Vertical lens shift stopped” (Error)
This error code is probably preceded by the warning code 8130: “Vertical lens shift stopped”. The same troubleshooting table can
be applied to.
Code 8132: “Lens focus stopped” (Warning)
Situation
Solution
Lens not mounted.
Install lens. See installation manual of the HDF projector.
Focus range not calibrated.
Calibrate the lens. See installation manual of the HDF projector.
Lens malfunction.
Replace lens. See installation manual of the HDF projector.
Code 8133: “Lens focus stopped” (Error)
This error code is probably preceded by the warning code 8132: “Lens focus stopped”. The same troubleshooting table can be
applied to.
Code 8134: “Lens zoom stopped” (Warning)
Situation
Solution
Lens not mounted.
Install lens. See installation manual of the HDF projector.
Zoom range not calibrated.
Calibrate the lens. See installation manual of the HDF projector.
Lens malfunction.
Replace lens. See installation manual of the HDF projector.
Code 8135: “Lens zoom stopped” (Error)
This error code is probably preceded by the warning code 8134: “Lens zoom stopped”. The same troubleshooting table can be
applied to.
Code 8502: “Reading lamp info module” (Error)
Situation
Solution
Damaged Lamp Info module
sockets.
1.
Check if the blue socket at the front of the Lamp House (reference 1 image 5-11) is
not damaged. If damaged, replace the Lamp Info module.
2.
Check if the blue socket inside the Lamp House compartment (reference 2
image 5-12) is not damaged. If damaged, replace the main wire tree.
Wire unit of the Lamp Info module
socket is disconnected from the
Power Backplane.
Reconnect the wire unit (reference 6 image 5-13) with the Power Distribution board.
Malfunction Lamp Info Module. The
projector can not read from the
installed Lamp Info Module.
In case no other “board read errors” appears, replace the Lamp Info Module. The Lamp
Info Module is located inside the Lamp House, behind the blue socket.
Malfunction internal RS485
communication line. The FCB, MCB
and CLO also reports “read errors”.
Disconnect the boards one by one from the internal RS485 line until this error disappears.
Replace the board which makes this error goes away. See chapter "Projector block
diagram", page 15, to know which boards are using the internal RS485 communication
line. If the problem remains replace the PMP. See "Replacing the PMP board", page 156.
Code 8520: “Tilt rotation not allowed” (Warning)
Situation
Solution
The projector is tilted in a position
which is not allowed.
Ensure that the right side (input side) of the projector doesn’t face the ceiling. To know
the exact tilting range see installation manual of the HDF projector.
Tilt sensor is not calibrated.
Calibrate the tilt sensor. See installation manual of the HDF projector for tilt sensor
calibration procedure.
R5905312 HDF W SERIES 24/01/2013
87
Содержание HDF W series
Страница 1: ...HDF W series Service manual R5905312 01 24 01 2013 ...
Страница 4: ......
Страница 8: ...Table of contents 4 R5905312 HDF W SERIES 24 01 2013 ...
Страница 12: ...1 Safety 8 R5905312 HDF W SERIES 24 01 2013 ...
Страница 30: ...3 Preventative maintenance actions 26 R5905312 HDF W SERIES 24 01 2013 ...
Страница 35: ...5 Troubleshooting 5 TROUBLESHOOTING R5905312 HDF W SERIES 24 01 2013 31 ...
Страница 36: ...5 Troubleshooting 32 R5905312 HDF W SERIES 24 01 2013 ...
Страница 110: ...6 Removal and installation of the projector covers 106 R5905312 HDF W SERIES 24 01 2013 ...
Страница 111: ...7 Power Input 7 POWER INPUT R5905312 HDF W SERIES 24 01 2013 107 ...
Страница 112: ...7 Power Input 108 R5905312 HDF W SERIES 24 01 2013 ...
Страница 120: ...7 Power Input 116 R5905312 HDF W SERIES 24 01 2013 ...
Страница 172: ...10 Card Cage 168 R5905312 HDF W SERIES 24 01 2013 ...
Страница 182: ...11 Lamp Power Supply 178 R5905312 HDF W SERIES 24 01 2013 ...
Страница 183: ...12 Start Pulse Generator 12 START PULSE GENERATOR R5905312 HDF W SERIES 24 01 2013 179 ...
Страница 184: ...12 Start Pulse Generator 180 R5905312 HDF W SERIES 24 01 2013 ...
Страница 192: ...12 Start Pulse Generator 188 R5905312 HDF W SERIES 24 01 2013 ...
Страница 242: ...14 Lenses and Lens Holder 238 R5905312 HDF W SERIES 24 01 2013 ...
Страница 266: ...15 Liquid cooling circuit Image 15 39 Electrical connection 262 R5905312 HDF W SERIES 24 01 2013 ...
Страница 269: ...15 Liquid cooling circuit Image 15 45 Electrical connection R5905312 HDF W SERIES 24 01 2013 265 ...
Страница 270: ...15 Liquid cooling circuit 266 R5905312 HDF W SERIES 24 01 2013 ...
Страница 274: ...16 Heat exchanger Image 16 5 Remove assembly 270 R5905312 HDF W SERIES 24 01 2013 ...
Страница 280: ...16 Heat exchanger Image 16 13 276 R5905312 HDF W SERIES 24 01 2013 ...
Страница 309: ...19 Board Diagnostic LED s 19 BOARD DIAGNOSTIC LED S R5905312 HDF W SERIES 24 01 2013 305 ...
Страница 310: ...19 Board Diagnostic LED s 306 R5905312 HDF W SERIES 24 01 2013 ...
Страница 328: ...19 Board Diagnostic LED s 324 R5905312 HDF W SERIES 24 01 2013 ...