4. Installation procedures
Additional notes
•
Care should be taken not to overload the connector during termination as this could result in damage. A positive stop should
be incorporated into the termination tooling to prevent over termination.
•
Blue sealing gel mats should be kept clean and dry prior to connector termination. A quick visual check can be done prior to
termination.
•
Cable pierce terminals can be damaged if the pre terminated connector is dropped. Damage to these pins may result in an
open circuit.
•
If possible an electrical test should be conducted after each connector termination to verify that continuity has been made to
each conductor and that there is no short circuit between conductors.
•
Cable punching and connector termination needs to be completed in a dry, controlled environment as there is a risk of hipot
failures or short circuits due to moisture ingress prior to
fi
nal connector closure.
•
The terminated connector should be kept dry prior to mating with the FLX-60 pixel.
•
The cable length between the Amphenol connector and the
fi
rst FLX-60 socket should be half the cable pitch. Otherwise, the
extra length must be considered as an extension cable.
•
The cable length between the Amphenol connector and the last FLX-60 socket should be half the cable pitch. Otherwise, the
extra length must be considered as an extension cable.
R59770419 FLX-60 12/05/2010
49
Содержание FLX-60
Страница 1: ...FLX 60 Installation manual R59770419 00 12 05 2010...
Страница 6: ...Table of contents 2 R59770419 FLX 60 12 05 2010...
Страница 18: ...2 Installation requirements 14 R59770419 FLX 60 12 05 2010...
Страница 55: ...4 Installation procedures Reverse this procedure to remove the FLX 60 pixel R59770419 FLX 60 12 05 2010 51...
Страница 63: ...4 Installation procedures Image 4 21 R59770419 FLX 60 12 05 2010 59...
Страница 64: ...4 Installation procedures 60 R59770419 FLX 60 12 05 2010...
Страница 78: ...B Specifications 74 R59770419 FLX 60 12 05 2010...