Luminance (cd/m

| ftL)

HVA

HVM

(

1

)

HVX

(

2

)

XGA

100W

95 | 28

170 | 50

425 | 125

120W

114 | 33

190 | 57

515 | 150

SXGA

+

100W

110 | 33

190 | 55

495 | 145

120W

125 | 40

230 | 65

560 | 165

Operating conditions

Rel. humidity

Up to 90% non condensing 

Temperature

10°C-40°C|50°F-105°F

Storing conditions

0°C-40°C|32°F-105°F

Optical dimming with dynamic
feedback

A patent pending optical dimming
system in combination with a dynamic
feedback control loop results in a
uniform image across the wall and
maintains the brightness over time.
This feature allows:

independent brightness control of
each module without loss of contrast
or color depth

equal brightness, contrast and color
depth across the display wall

equal luminance of the display wall
across time

ergonomic dimming of full display
wall for day and night operation

OverView Control Manager

control of the wall from any place

graphical user interface represents the
display wall on your desktop

exchanges information between
display modules

display wall health status

brightness control

lamp overview and report

Structure

O

VER

V

IEW

fDG70-DL

O

VER

V

IEW

fDR

+

70-DL

W

1,400 mm | 55.1 inch

H

1,050 mm | 41.34 inch

R

70" nominal

D1

793 mm | 31.2 inch

D2

689,5 mm | 27.15 inch

Aspect ratio

4:3 

SH (

1

)

1,288 mm | 50.7 inch

SH (

1

)

836 mm | 32.9 inch

SH min (

1

)

613 mm | 24.1 inch

(

1

) standard. Other support heights possible upon request

(

1

) Option, (

2

) on special request

Redundancy concept

dual lamp: 100% availability of your
display wall

2 modes:

Hot standby

: 2nd lamp is on, i.e. the

switching time in case of lamp failure
of the master lamp is virtually zero

Cold standby

: 2nd lamp is switched

off during operation, i.e. it will only
be activated when master lamp
failure is detected – switching takes
around 30 seconds

lamp change without direct operator
intervention 

W

H

R

SH

D2

D1

hot swappable lamps: failed lamp can
be replaced while other lamp
generates image

lamp changes can be planned 

lower operational costs

Dual DVI-D input on SXGA

+

version:

allows connection of two
simultaneous sources or controllers for
full redundancy upon failure of one
source or controller