4. Physical installation
Environment
Ambient operating
temperature
Relative humidity
Storage Conditions
1500 – 3000 M
10 to 35 °C
10 to 80 %
-20 to 60 °C, 10 – 90 %
Maximum air
fl
ow
900 m
3
/ hour
-
NA
AutoDim function
The F90 AutoDim function is integrated in the projector
fi
rmware. The projector continually senses and calculates the ambient
temperature in the installation location and will, when necessary, automatically dim the light output if the projector is operating in the
extreme ends of the recommended ambient environmental conditions, as illustrated in the graph below.
70
75
80
85
90
95
100
34
35
36
37
38
39
40
41
42
43
44
45
Light Output
[%
]
Ambient Temperature [
o
C]
Rel. Humidity=45%
Rel. Humidity=55%
Rel. Humidity=65%
Rel. Humidity=80%
Image 4-1
Mains power requirements
Projector
Power requirements
F90
110 — 240 V, 50 — 60 Hz
To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommends that the instrument panel
and cabinet be grounded.
In no event shall this projector be operated without an adequate cabinet ground connection.
The AC supply must be installed by a quali
fi
ed electrician in conformance to local codes. Hardware, wire sizes and conduit types
must comply with local codes.
AutoDim function will be activated when mains power are 110V or below.
26
601–0400–00 F90–W13 18/08/2016
Содержание F90-W13
Страница 1: ...F90 W13 User Manual 601 0400 00 00 18 08 2016 ...
Страница 28: ...3 Lenses 24 601 0400 00 F90 W13 18 08 2016 ...
Страница 46: ...6 Source menu DVI 1 DVI 2 DP 1 DP 2 HDBaseT HDMI SDI 42 601 0400 00 F90 W13 18 08 2016 ...
Страница 52: ...9 Settings menu 48 601 0400 00 F90 W13 18 08 2016 ...
Страница 54: ...10 Status menu Lists the projector IP address 50 601 0400 00 F90 W13 18 08 2016 ...
Страница 56: ...11 Reset Menu 52 601 0400 00 F90 W13 18 08 2016 ...