5. Important information

零件

(

名称

)

Component name

有毒有害物

或元素

Hazardous substances and elements

Pb

Hg

Cd

Cr6+

溴联

PBB

二苯

PBDE

盘说

CD manual

o

o

o

o

o

o

本表格依据

SJ/T 11364

This table is prepared in accordance with the provisions of SJ/T 11364.

o:

表示

有毒有害物

部件所有均

材料中的含量均在

GB/T 26572

定的限量要求以下

.

o: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for
this part is below the limit requirement in GB/T 26572.

x:

表示

有毒有害物

至少在

部件的某一均

材料中的含量超出

GB/T 26572

定的限量要求

.

x: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous
materials used for this part is above the limit requirement in GB/T 26572.

在中国大

陆销

售的相

应电

子信息

品(

EIP

)都必

遵照中国大

品有害物

限制使用

标识

要求》

保使用期限(

EFUP

标签

Barco

品所采用的

EFUP

标签

阅实

例,徽

内部的

号使用于指定

品)基于中国大

的《

子信息

保使用期限通

准。

All Electronic Information Products (EIP) that are sold within Chinese Mainland must comply with the
“Marking for the restriction of the use of hazardous substances in electrical and electronic product” of Chi-
nese Mainland, marked with the Environmental Friendly Use Period (EFUP) logo. The number inside the
EFUP logo that Barco uses (please refer to the photo) is based on the “General guidelines of environ-
ment-friendly use period of electronic information products” of Chinese Mainland.

10

5.3

Biological hazard and returns

Overview

The structure and the speci

fi

cations of this device as well as the materials used for manufacturing makes

it easy to wipe and clean and therefore suitable to be used for various applications in hospitals and other
medical environments, where procedures for frequent cleaning are speci

fi

ed.

However, normal use shall exclude biological contaminated environments, to prevent spreading of infec-
tions.

Therefore use of this device in such environments is at the exclusive risk of Customer. In case this device
is used where potential biological contamination cannot be excluded.

Customer shall implement the decontamination process as de

fi

ned in the latest edition of the ANSI/AAMI

ST35 standard on each single failed Product that is returned for servicing, repair, reworking or failure
investigation to Seller (or to the Authorized Service Provider). At least one adhesive yellow label shall be
attached on the top site of the package of returned Product and accompanied by a declaration statement
proving the Product has been successfully decontaminated.

Returned Products that are not provided with such external decontamination label, and/or whenever such
declaration is missing, can be rejected by Seller (or by the Authorized Service Provider) and shipped back
at Customer expenses.

K5902146 (451920612622) EONIS 12/01/2018

25

Содержание Eonis MDRC-2222 WP

Страница 1: ...Eonis User Guide 22 inch clinical display MDRC 2222 option BL MDRC 2222 option TS MDRC 2222 option WP K5902146 451920612622 01 12 01 2018...

Страница 2: ...26 22 62 Support www barco com en support Visit us at the web www barco com Registered address Barco NV President Kennedypark 35 8500 Kortrijk Belgium Phone 32 56 23 32 11 Fax 32 56 26 22 62 Support...

Страница 3: ...e adjustment 13 3 8 sRGB color space 13 3 9 QAWeb presets 14 3 10 Display functions 14 3 11 White point selection 15 3 12 Analog video settings 15 3 13 Power save mode 16 3 14 OSD menu language 16 3 1...

Страница 4: ...Table of contents 2 K5902146 451920612622 EONIS 12 01 2018...

Страница 5: ...diCal QAWeb software an online service for automated calibration Quality Assurance and asset management Praised in hospitals around the world MediCal QAWeb allows healthcare IT and PACS administrators...

Страница 6: ...ing on the region of operation 1x user guide 1x CD containing MediCal QAWeb Agent and translated user guides The user guide is available in other languages on www barco com support Keep your original...

Страница 7: ...values in the OSD menu Turn counter clockwise o to scroll up in the OSD menu o to decrease values in the OSD menu 3 Front sensor 4 Power status LED Off Display not powered or display is on but power L...

Страница 8: ...nnector 3 USB A 2 0 downstream connectors 2x 4 DisplayPort video input 5 Earth pin 6 DVI I video input 7 100 240 VAC mains power input IEC C14 8 Height adjustable cable routing clip 9 VESA 100 mm moun...

Страница 9: ...the fixa tion of all cables to avoid unwanted detachment CAUTION The monitor is not intended to be sterilized 2 1 Cable connections To connect the cables 1 Connect one or more video source s to the co...

Страница 10: ...outlet by means of a yellow green AWG18 wire maximum admitted cable length according to national regulation requirements Image 2 4 5 Route all cables through the provided cable routing clip at the bac...

Страница 11: ...nput is landscape If you use the display in portrait mode make sure you change the orientation of the video input via the screen settings of the computer 2 3 VESA mount installation To mount the displ...

Страница 12: ...he panel from the stand Image 2 6 2 Use 4 M4 screws to attach the panel to a VESA approved arm Please respect the following rule to select an appropriate screw length Lmin T W 8 mm Lmax T W 14 mm T W...

Страница 13: ...een saver displays moving content In case you are working with the same image or an application with static image elements for several hours continuously so that the screen saver is not activated chan...

Страница 14: ...eel to go into a submenu or confirm adjustments and selections 3 4 Power status LED Overview The power status of the display is indicated by a LED at the front of the display Below is an overview of t...

Страница 15: ...he OSD main menu 2 Navigate to the Input selection menu 3 Select one of the available input sources and confirm 3 7 Luminance adjustment To adjust the luminance 1 Bring up the OSD main menu 2 Navigate...

Страница 16: ...defined These functions emphasize on these parts containing crucial diag nostic information by correcting the native panel behavior The available display functions for your MDRC 2222 are Native If you...

Страница 17: ...film color temperature Clearbase Simulation of the clearbase film color temperature Programmable When selecting this setting you will be able to manually adjust the video gain for the red green and bl...

Страница 18: ...3 14 OSD menu language About the OSD menu language By default the OSD menu comes up in English However there s a wide range of other languages avail able for the OSD menu of your MDRC 2222 To select...

Страница 19: ...to fully restore the display to its original factory setting To perform a factory reset 1 Bring up the OSD main menu 2 Navigate to the Adjustments Settings menu 3 Enter the Factory Reset submenu 4 Sel...

Страница 20: ...3 Operation 18 K5902146 451920612622 EONIS 12 01 2018...

Страница 21: ...xcessive pressure on the front glass or LCD CAUTION Do not apply or spray liquid directly to the display as excess liquid may cause damage to internal electronics Instead apply the liquid to a cleanin...

Страница 22: ...0 Strong alkalis lye strong solvents Acid Detergents with fluoride Detergents with ammonia at higher concentration 1 6 Detergents with abrasives Steel wool Sponge with abrasives Steel blades Cloth wit...

Страница 23: ...oxide The equipment shall not be operable when the air oxygen content is above 25 Non patient care equipment Equipment primarily for use in a health care facility that is intended for use where conta...

Страница 24: ...et which has been approved and complies with the safety standard of your particular country Grounding reliability Grounding reliability can only be achieved when the equipment is connected to an equiv...

Страница 25: ...r application level it is necessary to foresee a backup unit in case the video falls away National Scandinavian Deviations for CL 1 7 2 Finland Laite on liitett v suojamaadoituskoskettimilla varustett...

Страница 26: ...ardous substances that Barco s product may contain The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China in the section Limit Requirements of to...

Страница 27: ...ructure and the specifications of this device as well as the materials used for manufacturing makes it easy to wipe and clean and therefore suitable to be used for various applications in hospitals an...

Страница 28: ...talled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation I...

Страница 29: ...or relocate the receiving antenna or equipment Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is...

Страница 30: ...should be at levels characteristic of a typical location in a typical commercial or hospital environment Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3 V m 150 kHz to 80 MHz 9 to 28 V m in co...

Страница 31: ...d 1 2 P 80MHz to 800MHz d 1 2 P 800MHz to 2 5GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 2 Field strengths from fixed transmitters such as base stations for radio cellular cordle...

Страница 32: ...ower supply you may find the following symbols nonrestrictive list Indicates the device meets the requirements of the applicable EC directives Indicates compliance with Part 15 of the FCC rules Class...

Страница 33: ...Indicates the temperature limitations5 for the device to safely operate within specs Indicates the device serial number Indicates the device part number or catalogue number Warning dangerous voltage...

Страница 34: ...entical boxes which may be stacked on each other where n is the limiting number xx yy Kg or xx yy xx yy Indicates the weight of the box and that it should be carried with two persons Indicates that th...

Страница 35: ...notice This document is copyrighted All rights are reserved Neither this document nor any part of it may be reproduced or copied in any form or by any means graphical electronic or mechanical includin...

Страница 36: ...ith stand 5 6 kg Net weight w o stand 3 3 kg Net weight packaged 7 0 kg without optional accessories Tilt 5 to 22 Pivot 90 Height adjustment range 110 mm Mounting standard VESA 100 mm Screen protectio...

Страница 37: ...21 5 Active screen size H x V 476 x 268 mm 18 7 x 10 5 Aspect ratio H V 16 9 Resolution 2MP 1920 x 1080 pixels Pixel pitch 0 248 mm Color imaging Yes Gray imaging Yes Bit depth 30 bit Viewing angle H...

Страница 38: ...creen protection N A Recommended modalities All digital images except digital mammography Certifications CE MDD 93 42 EEC A1 2007 47 EC class I device CE 2014 30 EU RoHS EN 60601 1 2 2015 IEC 60950 1...

Страница 39: ...Front Consistency Sensor Maximum luminance panel typical 300 cd m DICOM calibrated luminance 180 cd m Contrast ratio panel typical 1000 1 Response time Tr Tf 2 typical 7 5 ms Housing color RAL 9016 V...

Страница 40: ...2003 2nd Edition IEC 60601 1 2005 C1 2006 C2 2007 A1 2012 ANSI AAMI ES60601 1 A1 2012 C1 2009 R 2012 A2 2010 R 2012 CAN CSA C22 2 No 60601 1 2014 DEMKO EN 60601 1 2006 A12 2014 A1 2013 KC FCC class B...