E. Troubleshooting
Error
code
Description
Error
Warning
Caused by
Action
4198
FPGA PMP init
failed
Yes
-
6099
Board ID
unkown
version
Yes
6098
Board ID
invalid string
Yes
7999
DMD temp low
Yes
Yes
Low temperature on DMD
turning on the lamp(s) will heat up
the DMD
7998
DMD temp high
Yes
Yes
High temperature on DMD
check if air slots are free, clean air
fi
lters.
If problem persists, call a quali
fi
ed
service engineer.
7997
Ambient temp
low
Yes
Yes
Ambient temperature out of
speci
fi
cations
take measurements to increase the
temperature
7996
Ambient temp
high
Yes
Yes
Ambient temperature out of
speci
fi
cations
check ambient conditions
check if air slots are free, clean air
fi
lter.
7995
TEC temp low
7994
TEC temp high
Yes
Yes
7992
LPS1 temp
high
Yes
Yes
High temperature on LPS1
check if air slots are free, clean air
fi
lters.
If problem persists, call a quali
fi
ed
service engineer.
7990
LPS2 temp
high
Yes
Yes
High temperature on LPS2
check if air slots are free, clean air
fi
lters.
If problem persists, call a quali
fi
ed
service engineer.
7988
LPS3 temp
high
Yes
Yes
High temperature on LPS3
check if air slots are free, clean air
fi
lters.
If problem persists, call a quali
fi
ed
service engineer.
7986
LPS4 temp
high
Yes
Yes
High temperature on LPS4
check if air slots are free, clean air
fi
lters.
If problem persists, call a quali
fi
ed
service engineer.
7978
Lamp4 temp
high
Yes
Yes
High temperature on lamp 4
check if air slots are free, clean air
fi
lters.
If problem persists, call a quali
fi
ed
service engineer.
7924
Fan radiator A
low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
7922
Fan radiator B
low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
7920
Fan outlet A
low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
7918
Fan outlet B
low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
7916
Fan power
supply A low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
7914
Fan power
supply B low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
7912
Fan LPS A low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
7910
Fan LPS B low
Yes
Yes
Fan is running too slow or not at all
If problem persists, call a quali
fi
ed
service engineer
206
R59770057 CLM HD8 15/03/2010
Содержание CLM HD8
Страница 1: ...CLM HD8 User guide R9050130 R90501301 R90501305 R59770057 08 15 03 2010 ...
Страница 14: ...1 Safety 10 R59770057 CLM HD8 15 03 2010 ...
Страница 22: ...2 General 18 R59770057 CLM HD8 15 03 2010 ...
Страница 34: ...3 Physical installation 30 R59770057 CLM HD8 15 03 2010 ...
Страница 62: ...7 Start up of the adjustment mode 58 R59770057 CLM HD8 15 03 2010 ...
Страница 72: ...8 Input menu 68 R59770057 CLM HD8 15 03 2010 ...
Страница 113: ...10 Layout menu Image 10 61 Image 10 62 Image 10 63 Image 10 64 R59770057 CLM HD8 15 03 2010 109 ...
Страница 114: ...10 Layout menu 110 R59770057 CLM HD8 15 03 2010 ...
Страница 156: ...13 Projector control 152 R59770057 CLM HD8 15 03 2010 ...
Страница 170: ...14 Service menu 166 R59770057 CLM HD8 15 03 2010 ...
Страница 184: ...16 Servicing 180 R59770057 CLM HD8 15 03 2010 ...
Страница 193: ...17 Projector covers removal and installation Image 17 18 Secure the lamp door R59770057 CLM HD8 15 03 2010 189 ...
Страница 194: ...17 Projector covers removal and installation 190 R59770057 CLM HD8 15 03 2010 ...
Страница 202: ...C DMX Chart 198 R59770057 CLM HD8 15 03 2010 ...
Страница 208: ...D Specifications 204 R59770057 CLM HD8 15 03 2010 ...
Страница 214: ...E Troubleshooting 210 R59770057 CLM HD8 15 03 2010 ...
Страница 220: ...F Mounting optional Carry handle 216 R59770057 CLM HD8 15 03 2010 ...
Страница 222: ...G Order info 218 R59770057 CLM HD8 15 03 2010 ...
Страница 230: ...Index 226 R59770057 CLM HD8 15 03 2010 ...