7. Installation Adjustment Mode
Following screen will be displayed when starting this CRT Projection Angle Adjustment:
CRT PROJECTION ANGLE
ADJUSTMENT
CRT PROJECTION ANGLE IS THE
FIRST STEP OF STATIC
CONVERGENCE ADJUSTMENT
IT IS CRITICAL THAT THE
RASTERS ARE CENTERED ON
THE CRT FACE PLATES PRIOR
TO PERFORMING THIS STEP
<ENTER> to continue
<EXIT> to return
Menu 7-6
Never try to correct this misalignment with the shift correction or the static convergence controls. These shift
correction controls may only be applied to correct small errors which cannot be corrected by the CRT angle
adjustment. The Horizontal Shift and Vertical Shift for Red and Blue should be set near 50%.
Be sure that the rasters are centered on the CRT faceplate.
How to adjust the CRT Projection Angle?
1. Press
ENTER
to continue with the crosshair alignment.
Following screen will be displayed: (menu 7-7)
2. Press
ENTER
to begin with the angle adjustment of the Red CRT.
3. Loosen bolts A + B, on the top of the optical block and C + D, on the bottom of the optical block to pivot the Red CRT until the
center of the red image and the center of the green image coincide. (image 7-11, image 7-12)
4. When the angle of the Red CRT is corrected, tighten the four bolts.
5. Press
ENTER
to continue with the angle adjustment of the Blue CRT.
6. Loosen bolts E + F, on the top of the optical block and G + H, on the bottom of the optical block to pivot the blue CRT until the
center of the blue image and the center of the green image coincide. (image 7-13, image 7-14)
7. When the angle of the blue CRT is corrected, tighten the four bolts.
8. Press
ENTER
to continue with the Sheimpflug Adjustment (Diagonal Image Focusing) menu.
CRT PROJECTION ANGLE
ADJUSTMENT
DURING THIS PROCEDURE? RED
ON GREEN AND THEN BLUE ON
GREEN CROSSHAIRS WILL BE
ALIGNED WITH THE GREEN CRT
LOOSEN BOLTS A, B, C AND D TO
PIVOT THE RED CRT AND BOLTS
E, F, G AND H TO PIVOT THE
BLUE CRT
<ENTER> to continue
<EXIT> to return
Menu 7-7
R5976354 BARCOREALITY 908 SPLIT PACK 10092002
53
Содержание BarcoReality 908
Страница 1: ...SIMULATION PRODUCTS BARCOREALITY 908 SPLIT PACK R9040080 INSTALLATION MANUAL 10092002 R5976354 00...
Страница 4: ......
Страница 6: ......
Страница 8: ...Table of contents 2 R5976354 BARCOREALITY 908 SPLIT PACK 10092002...
Страница 12: ...1 Safety Instructions 6 R5976354 BARCOREALITY 908 SPLIT PACK 10092002...
Страница 18: ...2 Packaging and Dimensions 12 R5976354 BARCOREALITY 908 SPLIT PACK 10092002...
Страница 22: ...3 Installation Guidelines Image 3 4 Front Table positioning 16 R5976354 BARCOREALITY 908 SPLIT PACK 10092002...
Страница 23: ...3 Installation Guidelines Image 3 5 Front Ceiling positioning R5976354 BARCOREALITY 908 SPLIT PACK 10092002 17...
Страница 26: ...3 Installation Guidelines 20 R5976354 BARCOREALITY 908 SPLIT PACK 10092002...
Страница 36: ...4 Installation Setup 30 R5976354 BARCOREALITY 908 SPLIT PACK 10092002...
Страница 40: ...5 AC Power 34 R5976354 BARCOREALITY 908 SPLIT PACK 10092002...
Страница 52: ...6 Source Connections 46 R5976354 BARCOREALITY 908 SPLIT PACK 10092002...
Страница 68: ...A Gamma Corrections 62 R5976354 BARCOREALITY 908 SPLIT PACK 10092002...
Страница 71: ...B Material Safety Data Sheet Image B 2 R5976354 BARCOREALITY 908 SPLIT PACK 10092002 65...
Страница 72: ...B Material Safety Data Sheet 66 R5976354 BARCOREALITY 908 SPLIT PACK 10092002...