Outdoor BBQ Built-in Installation Specifications
NOTE:
When choosing a location for your Gas grill, keep in
mind that it should not be located under any overhead com-
bustible construction. The side and bottom of the grill should
not be any closer than 14 inches to combustible construction,
and the back of the grill should not be any closer than 16
inches to combustible construction.
Prior to installing unit, 2 spacers must be installed underneath
the barbecue to provide ample accessibility to the drip tray.
Attach using
four 1/4-20 UNC Bolts and two Nuts
as shown
in
Figure 3
.
NOTE:
When using Propane, EXTREME CAUTION should
be used to provide ample ventilation of vapor from the enclo -
sure. LP Gas vapor is heavier than air and SERIOUS
INJURY from a DANGEROUS EXPLOSION could occur if LP
Gas is allowed to accumulate in an enclosure and then ignit-
ed. Both the Barbecue enclosure and LP cylinder enclosure
require venting that must be provided at the floor level of the
enclosure to allow any leaking LP Gas vapor to escape.
Upper & lower ground-level vents (20 sq. in. minimum each)
MUST BE PROVIDED on both sides of built-in construction.
Please ask a Barbeques Galore associate for full details.
NOTE:
When installing a barbecue equipped for liquid
propane in an island, the propane tank must be in a sepa-
rate enclosure that is completely isolated from the barbe-
cue. It must be cross-ventilated in accordance with the cur-
rent standard. The propane tank MUST NEVER be installed
directly under the barbecue.
NOTE:
Upper & lower ground-level vents (20 sq. in. mini-
mum each)
MUST BE PROVIDED
for combustion air on
both sides of built-in construction. Please ask a Barbeques
Galore associate for full details.
Barbecues must be installed in accordance with CSA
specifications and all local building codes.
SPACERS
Figure 3
Stainless
Flexline
Non-combustible
Construction
Vented on
BOTH SIDES
of Island
Vented
Access
Door
CSA Approved Propane Regulator
CSA Approved
Rubber Gas Hose
QCC-1/OPD
Tank
Figure 5
Clamp down
flexline
- 6 -
NUT
BOLT
BOLT
NUTSERT
‹
WARNING
Vapors from products containing Chlorine and other caustic chem-
icals can cause Stainless Steel flexible connectors to corrode.
THESE PRODUCTS SHOULD NOT BE STORED IN AN ISLAND
OR NEAR THE connector.
Cleaning solutions, Household Chemicals and Solder fluxes can also cause pinholes if they come in contact with these con-
nectors and
MUST
be washed off immediately with water.
5-1/4” minimum clearance
from cutout (for Hood)
Non-combustible
Construction
Figure 4
Model
Height
Width
Depth
52" Built-in Y0662
10-1/2"
52-3/4"
24-3/16"
38" Built-in Y0663
10-1/2"
38-3/4"
24-3/16"
27" Built-in Y0665
10-1/2"
27-3/4"
24-3/16"
Built-in Side Burner
10-1/2"
17-3/4"
24-3/16"