background image

Parts  List  for  Models  TSB10ALP  &  TSB10ANG

6

Important:

  Use  only  Grand  Hall  replacement  parts.  The  use  of  any  part  that  is  not  a  Grand  Hall  replace-

ment  part  can  be  dangerous  and  will  also  void  your  product  warranty.  Keep  this  Operator's  Manual  for
convenient  referral  and  for  part  replacement.

To  obtain  the  correct  replacement  parts  for  your  gas  side  burner,  please  refer  to  the  part  numbers  in  this
parts  list.  The  following  information  is  required  to  ensure  you  receive  the  correct  parts:
1.  Model  and  Serial  Number  (see  CSA  label  on  side  burner)
2.  Part  Number
3.  Part  Description
4.  Quantity  of  parts  needed

For  the  repair  or  replacement  parts  you  need:

Call 1-877-934-7455 M-F 8AM-4:30PM CST

KEY

DESCRIPTION

PART #

 QTY

1

Knob/Side Burner Lid

P00215038A

1

2

Lid

P0011554AA

1

2a

Lid Chain

P05522002A

1

3

Pot Support

P016040476

1

4

Side Burner Body

P0073958FC

1

5

Side Burner Frame

P0073961F4

1

6

Gas Valve/Manifold Assembly

Y0060735

1

6a

Connection Hose/Gas Manifold

P03715018A

1

6b

Gas Manifold

P03715019B

1

7

Bracket for NG Regulator (NG)

P033040544

1

8

Grease Tray

P02718064B

1

9

Trim Plate Left/Right

P03304064C

2

10

Side Burner Frame Support Bracket

P03304059C

2

11

Control Panel

P0290448IX

1

12

Panel, Rear

P0075804FC

1

13

Side Burner

P02004041A

2

14

Side Burner Cap

P02013058E

2

Side Burner Orifice (LPG)

P06539034A

2

Side Burner Orifice (NG)

P06539035A

2

16

Connection Hose, Short

P03701033A

1

17

Connection Hose, Long

P03701034A

1

18

Orifice Bracket

P03328075C

2

19

Side Burner Electrode with Wire, Front

P02618054A

1

20

Side Burner Electrode with Wire, Rear

P02618055A

1

21

Regulator with Hose Assembly (NG)

P03614007A

1

22

Electronic Ignitor - 2 Ports

P02502252C

1

23

Control Knob

P03411503L

2

23a

Control Knob Spring

P05504021A

2

24

Control Knob Seat

P03415014S

2

25

Lighting Stick

P05313026B

1

26

Regulator with Hose and Connector (LPG)

P03601043A

1

27

Tank Holder Assembly (LPG)

P05358003T

1

28

Tank Holder Bracket, Left (LPG)

P03304055F

1

29

Tank Holder Bracket, Right (LPG)

P03304056F

1

Hardware Pack (LPG)

P06030020A

1

Hardware Pack (NG)

P06030021A

1

Operator Manual

P80151113A

1

15

Содержание Turbo TSB10ALP

Страница 1: ...heatersand live electrical appliances THIS GAS APPLIANCE IS DESIGNED FOR OUT DOORUSEONLY Never use this gasappliance on a balcony deck or patioabovethegroundfloorof yourhome Never use your gas side b...

Страница 2: ...urner use Remove any grease and wash Grease Tray with a mild soap and warm water solution Failureto complywith these instructions couldresultinagreasefireorexplosionthatcould cause serious bodily inju...

Страница 3: ...e before using your side burner See figure If the Orifice is not inside the Burner Tube lighting the Burner may cause explosion and or fire resulting in serious bodily injury and or property damage ME...

Страница 4: ...e Nut 3 16 2 S112G03066 Phillips Head Screw 3 16 x3 8 4 S313G03056 Flange Nut 3 16 4 S112G03081 Phillips Head Screw 3 16 x1 2 3 S313G03051 Flange Nut 3 16 3 S112G03061 Phillips Head Screw 3 16 x3 8 2...

Страница 5: ...Parts Diagram for Models TSB10ALP TSB10ANG 5 1 2 3 4 5 6 9 9 11 12 19 20 14 13 18 15 16 17 8 22 24 23 18 29 21 7 25 26 28 27 2a 10 23a 6a 6b...

Страница 6: ...ection Hose Gas Manifold P03715018A 1 6b Gas Manifold P03715019B 1 7 Bracket for NG Regulator NG P033040544 1 8 Grease Tray P02718064B 1 9 Trim Plate Left Right P03304064C 2 10 Side Burner Frame Suppo...

Страница 7: ...tighten using 2 Flange Nuts 3 16 Make sure to place the NG Regulator hose into the Hose Holder Install the NG Regulator Bracket onto your Island Side Panel using 3 Phillips Head Screws 3 16 x1 2 Tigh...

Страница 8: ...older Brackets onto the Island Bottom Panel using 4 Phillips Head Screws 3 16 x3 8 Tighten 4 Flange Nuts 3 16 onto the ends of the 4 Phillips Head Screws as shown Be sure that the flat surfaces of the...

Страница 9: ...see a blue spark within each Spark Electrode Tip If a spark is present the Electrode Tips are properly positioned If no spark is seen the Spark Gap needs to be adjusted as follows Side Burner Electrod...

Страница 10: ...that has a direct connection with the vapor space of the tank The tank supply system must be arranged for vapor withdrawal The LP Gas tank must have a collar to protect the tank valve WARNING Refer t...

Страница 11: ...f 1 8 See Fig 4 on page 9 Contact a Grand Hall associate for more details Note The built in appliance for use with a remote self contained LP Gas supply system must use rigid pipe semi rigid tubing or...

Страница 12: ...xplosion that could causeseriousbodilyinjury death or prop erty damage Check all connections for LP Gas Leaks Never test for leaks with an open flame Prior to first use at the beginning of each season...

Страница 13: ...se help keep the open ends clean while disconnected WARNING Do not routethe 12 Foot Quick Disconnect Hose under a deck The hose must be visible and inspected prior to each side burner use Natural Gas...

Страница 14: ...nd repeat the lighting procedure After one Burner is lit turn the tank valve SLOWLY one more 1 4 of a turn Before each use check all hoses for cracks nicks cuts burns or abrasions If a hose is damaged...

Страница 15: ...Gas Hose Turn tank valve on SLOWLY 1 4 of a turn For Natural Gas open Shut Off valve Open the side burner Lid Push and turn the Control Knob to HI and press the electric ignitor 3 to 4 seconds to ligh...

Страница 16: ...ction of the stainless steel grain or polish lines Do not polish against the grain 1 3 2 Failure to comply with these instructions could result inafire orexplosionthatcouldcauseserious bodily injury d...

Страница 17: ...o Figure 1 and perform one of these three cleaning methods Remove the screws from the rear of each Burner using a Phillips Head Screwdriver Carefully lift each Burner up and away from the Gas Valve Or...

Страница 18: ...ural Gas shut off NG valve Disconnect regulator from LP Gas tank For Natural Gas disconnect regulator from 12 ft Natural Gas Hose Let unit stand for 5 minutes Reconnect regulator to the LP Gas tank Fo...

Страница 19: ...Question What causes side burner parts to rust and what effect does it have on my side burner Answer Routine care and maintenance is required to preserve the appearance and corrosion resistance of sta...

Страница 20: ...ce or service damages caused by flashback fire or grease fires as set out in the Operator s Manual This warranty does not cover scratches dents corrosion or discoloration caused by weather heat abrasi...

Отзывы: